1.Clinical effects of oxytocin induced labor route
Huaping CHEN ; Limin CHEN ; Lifei XIA
Chinese Journal of Biochemical Pharmaceutics 2017;37(9):293-294
Objective To study and analyze the clinical effects of different oxytocin induced labor routes. Methods From March 2015 to September 2016, 100 pregnant women who needed induced labor or induced oxytocin were selected in our hospital. They were randomly divided into the control group and the study group, with 50 patients in each group. The control group with traditional infusion method, given intravenous indwelling needle puncture method in patients with the study group, select the vein elastic and straight, thick, pay attention to the reasonable sealing, adjust the dropping speed according to the patients with uterine contraction. The infusion speed, safety and accuracy of the patients in the study group and the control group were compared and analyzed. Results After the corresponding administration route, there were 0 patients with drop velocity errors in the study group, and 12 patients in the control group. In the control group, the rate of drop error was 24%, which was significantly higher than that of the study group (0%), with statistical difference (P<0.05). Among the patients in the study group, the number of blocked tubes was 1, the probability was 2%, the rate of subcutaneous infiltration was 4%, and the incidence of needle prolapse was 0%. In the control group, the rate of subcutaneous exudate was 10%, the probability of blockage was 8%, and the incidence of needle prolapse was 6%. The average time spent by the study group on regulation of drip speed was (8.09 ±2.10) s, significantly shorter than that of the control group (78.90 ± 9.20) s, with statistical difference (P<0.05). Conclusion Intravenous catheter infusion of oxytocin administered with traditional delivery mode, simple operation, can significantly reduce the drop speed error probability, the clinical effect is ideal, has the meaning of promotion.
2.PCD Used in Monitoring Sterilization Efficacy of Hydrogen Peroxide Gas Plasma Sterilizer
Jian ZHANG ; Shuxia XING ; Xia QIU ; Lifei WANG ; Liubo ZHANG
Chinese Journal of Nosocomiology 2006;0(12):-
OBJECTIVE To monitor the sterilization effect of hydrogen peroxide gas plasma sterilizer with process challenge derice(PCD).METHODS Hydrogen peroxide gas plasma sterilizer was used to sterilize different material and structure items in simulation field sterilization trial.The test pieces have been cultured for 7 days at 37 ℃.Make the test records in detail.RESULTS The hemostatic forceps,surface of lines and biological indicators,as well as 300 mm stainless steels tube and 2000 mm Teflon tube were sterilized successful.But 600 mm and 300 mm stainless steels of low temperature did not past the challenge tests.The results of test surface and test lumen were inconsistent.CONCLUSIONS PCD is need to be introduced in monitoring sterilization effect of hydrogen peroxide gas plasma sterilizer.