1.Curative effect analysis of oxycontin and MS contin in the treatment of sever cancerous pain
Yuanyuan SUN ; Xiaoyan CHEN ; Kesong WANG
Cancer Research and Clinic 2013;(1):36-37,40
Objective To evaluate effect and adverse effect of oxycontin and MS contin in the treatment of sever cancerous pain.Methods 204 patients with sever cancerous pain were randomly derided into 2 groups,oxycontin and MS contin group.Each pain was evaluated in every 48 hours and dose was adjusted according to the pain relief.And 2 groups were evaluated the analgesic onset time,effect and adverse effect,respectively.Results Efficiency was according to less than or equal to 3 of pain score after administer in analgesic effect.Effect rates of oxycontin group and MS contin group were 79.4 % (81/102) and 75.5 % (77/102) respectively,and the difference was not statistically significant (x2 =0.225,P > 0.05).However,there were significant differences in the analgesic onset time between two groups (x2 =22.916,P < 0.05).Adverse effect rates in oxycontin group and MS contin group were 62.7 % (64/102) and 98.0 % (99/102)respectively,and the difference was statistically significant (x2 =20.151,P < 0.05).Conclusion Oxycontin and MS contin in the treatment of serious cancerous pain have the same controlling effect.But oxycontin worked better with quick analgesic onset,low incidence and few of adverse reaction.
2.Budesonide inhibits murine asthmatic airway inflammation through reduction IL-22 secretion
Minglei WANG ; Wenge WANG ; Junhong ZHANG ; Dawei ZHANG ; Kesong YAN
Chinese Journal of Comparative Medicine 2017;27(5):55-59
Objective To study the effect of Interleukin-22 (IL-22) on murine asthmatic airway inflammation and airway remodeling, observe the effect of budesonide on IL-22 of asthmatic mouse model, explore the mechanism of budesonide in the treatment of asthma.Methods Ovalbumin(OVA) was used as an allergen to sensitize and challenge the mice.24 female specific-free (SPF) BALB/c mice aged four weeks were randomly divided into 3 groups:control group, asthma group and budesonide treatment group (BUD group).For Histopathological Examination, HE staining was used to measure the inflammation scores, AB-PAS staining was used to measure the hyperplasia of goblet cells and mucin.Enzyme-linked immunosorbent assay(ELISA) was used to analyze IL-22 levels in bronchoalveolar lavage fluid (BALF).Quantitative Real-time PCR was performed to analyze the effects of budesonide on IL-22 mRNA levels in lung tissue.Results The inflammation scores of asthma group were elevated compared with the control group.An overall change towards less severe asthmatic airway inflammation by the end of the trial was observed in the BUD group.IL-22 levels in BALF were significant decreased after the treatment of budesonide, the mRNA levels of IL-22 were obviously decreased in BUD group, too.A significant positive correlation was observed between the mRNA levels of IL-22 and airway inflammation.Conclusions The increasing IL-22 secretion can lead to the occurrence of airway inflammation of asthma.Budesonide can inhibit the expression of IL-22, thereby Budesonide could inhibit the development of airway inflammation of asthma.
3.Effect of oxycodone combined flurbiprofen ester in the treatment of postoperative analgesia after thoracic surgery
Chabing LI ; Feng XU ; Wei WANG ; Kesong ZHENG
The Journal of Clinical Anesthesiology 2016;32(12):1183-1185
Objective To observe the efficacy of oxycodone or fentanyl combined with flurbi-profen esters (FA)for postoperative analgesic after thoracic surgery.Methods Eighty patients,53 males and 24 females,aged 40-65 years,ASA physical status Ⅰ-Ⅲ,undergoing elective thoracotomy surgery,randomly divided into two groups (n =40 each).Oxycodone 0.1 mg/kg (group O)or fenta-nyl 1 μg/kg (group F)were intravenously injected 1 5 minutes before the end of surgery.Each patient was given PCIA,with solution including oxycodone 0.8 mg/kg plus FA 4 mg/kg plus ondansetron 8 mg plus 0.9% NaCl (1 50 ml)in group O and fentanyl 8 μg/kg plus FA 4 mg/kg plus ondansetron 8 mg plus 0.9% NaCl (1 50 ml)in group F.The coughing and resting visual analogue scale (VAS), Ramsay score at 2,6,12,24,36 and 48 hours after operation,complications,the times of patient controlled pressing and requirement for rescue analgesic were evaluated.Results Compared with group F, the resting and coughing VAS at 2, 6, 12, 24, 36 and 48 hours after operation, requirement for rescue analgesic,the incidence of nausea and vomiting and the times of patient con-trolled pressing were significantly lower in group O (P <0.05).There was no significantly difference in the Ramsay score.Conclusion It is effective that the patients undergoing thoracic surgery used the PCIA of oxycodone combined FA to control the postoperative pain, and analgesic effect more excellent than fentanyl combined FA,and with fewer side effects.
4.Application of orthopedic metal artifact reduction technology in CT examination of arthroplasty
Kesong ZHANG ; Xiaolin XU ; Qing HAN ; Yun ZOU ; Bingpeng CHEN ; Kerong YANG ; Hao JIANG ; Jincheng WANG
Journal of Jilin University(Medicine Edition) 2019;45(1):179-183,后插4
Objective:To investigate the metal artifact reduction effect of orthopedic metal artifact reduction (O-MAR) techonology and its improvement effect on the image quality in CT examination in the patients with arthroplasty, and to elaborate the significance of the technology in clinical diagnosis and treatment of arthroplasty.Methods:The CT data of 20patients with hip or knee prostheses was collected.There were two tube voltages in each group of CT data:120and 140Kev.There were also two groups of CT data in each tube voltage group:nonO-MAR group and O-MAR group;there were four subgroups of CT data of each case:120 Kev/-O-MAR, 120Kev/+O-MAR, 140Kev/-O-MAR, 140Kev/+O-MAR.After data collection, Mimics software was applied to conduct three-dimensional (3D) reconstruction for purpose of the qualitative and quantitative analysis of CT data.Qualitative analysis mainly included the grade of severity of metal artifact and quality of data.Quantitative analysis included the volume of metal artifact, the average CT value and standard deviation (SD) in region of interest (ROI) .ROI 1and ROI 2were chosen at the location of beam hardening artifact (radial high-density metal artifact) and photon starvation artifact (band low-density metal artifact) , respectively.Results:According to the result of3D measurement, the volumes of artifact had no significant difference between 120 Kev/-O-MAR group and140Kev/-O-MAR group (P=0.062) , but there were siginificant differences in the volumes of artifact between other groups (P<0.05) ;O-MAR technology decreased the volume of beam-hardening artifact obviously (P<0.05) .According to the results of two-dimensional (2D) measurement, there was no significant difference in the average CT values in ROI 2between 120Kev/-O-MAR group and 140Kev/-O-MAR group (P=0.069) , but there were significant differences in the average CT values between other groups (P<0.05) ;O-MAR technology decreased the high-density beam-hardening metal artifact and the low-density photon-starvation metal artifact in 2D measurement.Conclusion:O-MAR technology could significantly reduce the CT metal artifact of hip and knee prostheses and increase the clinical value of CT data.
5.Accuracy verification and reliability analysis of three-dimensional printing model in orthopedics and maxillofacial surgery
Yun ZOU ; Qing HAN ; Xiaolin XU ; Yingying YANG ; Kesong ZHANG ; Kerong YANG ; Yanguo QIN ; Yongwei ZOU ; Jincheng WANG ; Shouyi ZHANG
Journal of Jilin University(Medicine Edition) 2017;43(5):996-1001,后插6
Objective:To discuss the accuracy of stereolithography (SLA)-3D printing model in orthopedics and maxillofacial surgery,and to clarify the reliability of its clinical application.Methods:A total of 33 cases of SLA-3D printing models were randomly included (10 long bones,13 irregular bones and 10 prostheses),and the CT scanning and three-dimensional reconstruction were performed.According to the clinical application characteristics of the models,the max height (MH),max length (ML),max width (MW),width of the trochlear (WT),length of the trochlear (LT),length of the glenoid cavity (LGC),width of the glenoid cavity (WGC),distance of pubic tubercle-anterior superior iliac spine (DPI),diameter of the acetabulum (DA),diameter of the marrow cavity (DMC),anterior height of right ramus (AHRR) and posterior height of right ramus (PHRR) were selected to measure the original data and model data,respectively.The absolute / relative errors were calculated.Intraclass correlation coefficient (ICC) was used to evaluate the consistency of the data.The three-dimensional error analysis of the prosthesis model was carried out.Results:There were no significant differences in the anatomical parameters except MW of irregular bone (P>0.05) in 33 cases of SLA-3D printing model.The values of ICC were all greater than 0.950;the maximum values of absolute / relative errors were-0.58 mm and-1.37%,respectively;the maximum 3D error of prosthesis model was 0.237 mm,and the average value was 0.132 mm.Conclusion:The CT data of SLA-3D model is highly consistent with the original data,and it is accurate and reliable in the diagnosis and treatment of the diseases in orthopedics and maxillofacial surgery.
6.Effect of gender on neuromuscular blockade of rocuronium in epileptics
Mingming HAN ; Ziyou LIU ; Chengwei YANG ; Mingyu ZHAI ; Kesong ZHENG ; Ting WANG ; Yong WANG ; Dandan SUN ; Juan LI
Chinese Journal of Anesthesiology 2020;40(1):68-70
Objective:To evaluate the effect of gender on neuromuscular blockade of rocuronium in epileptics.Methods:Forty American Society of Anesthesiologists physical status Ⅱ or Ⅲ patients, aged 18-59 yr, with body mass index of 18.5-24.0 kg/m 2, scheduled for elective surgery for treatment of epilepsy under general anesthesia, were divided into 2 groups ( n=20 each) according to gender: male group (group M) and female group (group F). Neuromuscular conduction function was monitored with a muscle relaxation monitor.Ulnar nerve was stimulated in TOF mode (frequency 2 Hz, wave width 0.2 ms, stimulation current 70 mA and interval 12 s). Rocuronium 0.8 mg/kg was injected intravenously during anesthesia induction, and endotracheal intubation was performed when T l reached maximum inhibition.The conditions of endotracheal intubation were evaluated by the modified method.When T 1 recovered to 25% during operation, rocuronium 0.15 mg/kg was intravenously injected.Sugammadex sodium 2 mg/kg was injected intravenously when T 1 recovered to 50% after surgery.The onset time (T onset), peak time (T peak), 10% recovery time (T 10%), 10%-25% recovery time (T 10%-25%), 25%-50% recovery time (T 25%-50%), 50%-75% recovery time (T 50%-75%) and 75%-90% recovery time (T 75%-90%) of rocuronium were recorded.Peripheral venous blood samples (3 ml) were collected when T 1 recovered to 25% and 75%, and the concentration of rocuronium was detected by liquid chromatography-tandem mass spectrum.The consumption of rocuronium per unit of weight per minute was calculated. Results:There was no significant difference between the two groups in terms of T onset, T peak, T 10%, T 10%-25%, T 25%-50%, T 50%-75%, T 75%-90%, endotracheal intubation conditions, blood concentration of rocuronium at varied time points, or consumption of rocuronium per unit of weight per minute ( P>0.05). Conclusion:Gender exerts no effect on the neuromuscular blockade of rocuronium in epileptics.
7.The Effect from Elastic Modulus of Vessels on Fractional Flow Reserve of Carotid Artery Stenosis
Long YU ; Kesong XU ; Jun WAN ; Shengzhang WANG ; Haiyan LU
Journal of Medical Biomechanics 2020;35(4):E397-E402
Objective To explore the feasibility of applying fractional flow reserve (FFR) into the assessment of carotid stenosis, and analyze the effects from elastic modulus of vessel wall on hemodynamic parameters of carotid artery stenosis model and FFR calculation results. Methods The standard models of carotid bifurcation and stenosis models with different stenosis rates were established by computer-aided design software. Assuming that the vessel wall was linear elastic material and the blood was incompressible Newtonian fluid, the fluid-structure coupling simulation of blood flow in carotid artery stenosis model under the pulsating flow was carried out by finite element analysis, and the relevant hemodynamic parameters were obtained, and the corresponding FFR was calculated. Results When the elastic modulus was fixed, the FFR for narrow part of the model decreased gradually with the increase of the stenosis rate, and the relative difference between the FFR of elastic wall and rigid wall increased with the increase of the stenosis rate; when the stenosis rate was fixed at 70%, the FFR decreased gradually with the increase of elastic modulus. Conclusions The effect of vascular wall elasticity should be considered in the process of functional assessment on carotid stenosis with FFR; the larger stenosis rate will lead to the greater influence from elastic modulus of vessel wall on FFR.