1.A Report of Successful Treatment of an Infected Aortic Graft and Remaining Distal False Lumen after Bentall's Procedure for Aortic Dissection.
Koji Hattori ; Yoshihiro Shimizu ; Shuichiro Takanashi ; Keijiro Nishizawa ; Hirokazu Minamimura ; Toshihiro Fukui ; Kenu Fumimoto ; Masahito Noguchi
Japanese Journal of Cardiovascular Surgery 1999;28(5):347-350
We report a case of a 16-year-old boy with Marfan's syndrome who underwent Bentall's procedure on a diagnosis of acute aortic dissection (DeBakey type II). He was readmitted with pyrexia 5 months after the initial operation. Methicillin-resistant Staphylococcus epidermidis (MRSE) was detected by blood culture and transesophageal echocardiography revealed a vegetation adherent to the entry of a remaining false lumen just distal to the distal anastomosis. Although antimicrobial therapy was employed, an arterial embolism developed in the right popliteal artery. CT scan revealed dilatation of the false lumen, and consequently, emergency surgery was performed. The intima of the distal aortic end was partially out of the suture line and the vegetation adhered at that point. Re-replacement of the ascending aorta, omental transposition, and embolectomy of the right femoral artery were performed and resulted in a satisfactory course.
2.A Case of Aortic Anastomotic False Aneurysm Associated with a Graft-Duodenal Fistula.
Yasuyuki Sasaki ; Fumitaka Isobe ; Seiji Kinugasa ; Keiji Iwata ; Kenu Fumimoto ; Yasuyuki Kato ; Hideki Arimoto ; Hiroki Hata
Japanese Journal of Cardiovascular Surgery 2002;31(5):363-366
We report a case of successful surgical treatment for an aortic anastomotic false aneurysm associated with a graft-duodenal fistula after abdominal aortic aneurysm repair. A 63-year-old man was admitted with melena and an aortic anastomotic false aneurysm after prosthetic graft replacement 8 years previously. CT scan demonstrated an aneurysm with a maximum diameter of 70mm at the proximal anastomotis of the prosthetic graft. Gastroduodenoscopy revealed no bleeding site in the stomach or the first and second portions of the duodenum. Therefore, we performed an emergency operation under a diagnosis of an aortic anastomotic false aneurysm associated with a graft-duodenal fistula. The aneurysm was replaced with interposition of a new prosthetic graft via a thoracoabdominal approach. The fistula was repaired by covering the duodenum with the jejunum through a left pararectal laparotomy. The postoperative course was uneventful, and there was no evidence of graft infection at 14 months after the operation.
3.Aortic Valve Replacement for Aortic Stenosis in Patients 70 Years and Older
Yasuyuki Kato ; Shigefumi Suehiro ; Toshihiko Shibata ; Yasuyuki Sasaki ; Hidekazu Hirai ; Kenu Fumimoto ; Yasuyuki Bito ; Manabu Motoki ; Yosuke Takahashi
Japanese Journal of Cardiovascular Surgery 2005;34(6):389-394
We studied 73 patients, 70 years of age or older, who underwent aortic valve replacement for aortic stenosis between October, 1990 and October, 2004. There were 31 men and 42 women with a mean age of 75.7±3.6 years. Mechanical valves were implanted in 37 patients, and bioprostheses in 36 patients. Operative mortality was 1 of 73 (1.4%) and the New York Heart Association functional class improved to class I or class II in all of the hospital survivors. Follow-up (100%) extended from 0.3 to 11.6 years (mean 3.7 years). There were 16 late deaths (5.9% per patient-year), including valve-related deaths in 6 patients. The overall survival rates at 5 and 10 years was 74.2% and 44.3%, respectively. The freedom from valve-related events at 5 and 10 years was 78.8% and 78.8%, respectively. The 10-year survival rates and freedom from valve-related events were not different between the patients with mechanical valves and those with bioprostheses. The size of the implanted valve did not influence the late survival or freedom from valve-related events. The outcome after aortic valve replacement in the elderly (70 years and older) was excellent with low operative mortality, and acceptable late mortality and morbidity. Thus, aortic valve replacement for elderly patients should have the same indications as for younger patients. Bioprostheses showed good long-term results with no structural valve deterioration, thromboembolism, or bleeding events. Mechanical valves, which required the maintenance of an anticoagulant therapy, were also useful with acceptable late morbidity. The long-term results with small valves (≤19mm) were comparable to the results with large valves (>19mm) in the elderly. Thus, the use of these small valves in this particular age group seems to be acceptable.