1.Study on ventricular-arterial coupling in patients with type 2 diabetes mellitus by ultrasound
Zhaojun LI ; Chunsong KANG ; Jiping XUE ; Kailing SHI ; Xiaoyan CHEN
Chinese Journal of Ultrasonography 2012;21(9):757-761
Objective To study the ventricular-arterial coupling in the patients with type 2 diabetes mellitus (DM) by ultrasound.Methods Eighty patients with DM were divided into 2 groups:normal left ventricular ejection fraction (EF) group (DMN,EF≥50 %,n =40) and abnormal EF group (DMA,EF<50%,n =40).At the same time,42 healthy volunteers were selected as a control group.The left ventricular (LV) relative wall thickness (RWT),mass index (LVMI),stroke volume (SV),stroke works (SW),ratepressure product (RPP),systemic vascular resistance index (SVRI),LV end-systolic elastance (Ees),arterial elastance index (Ea) and ventricular vascular index (VVI) were measured and calculated.Longitudinal strain (LS) of myocardial segment including base(LSBA),papillary muscle (LSPM) and apex (LSAP) were analyzed by two-dimensional speckle tracking imaging.Results (1) Compared with the control,the RWT and LVMI were all increased (P <0.01),but the LSBA,LSPM and LSAP were decreased (P < 0.01) in the DMN and DMA groups (P <0.01).In DMA group,the RWT,LSBA,LSPM and LSAP were decreased (P <0.01).Compared with the DMN group,the LSBA,LSPM and LSAP were decreased in DMN group (P <0.01).(2) Compared with the control,the Ea,VVI,RPP and SVRI were increased,but the Ees was decreased (P <0.05)in DMA group (P <0.01).In the DMN,RPP was increased compared with the control group (P <0.01).Compared with the DMN group,the Ea,VVI,RPP and SVRI were increased,but Ees was decreased in the DMA (P <0.05).(3)The LSBA,LSPM and LSAP were all positively correlated with VVI(P <0.01).Multiple regression analysis showed that the LSAP,RWT,LVMI and SW were independent predictor of VVI (b' =-0.613,-0.290,0.290 and-0.205,P < 0.05).Conclusions The ventricular-arterial coupling is normal in the DMN group,but is abnormal in DNA group.LSAP is independent predictors for ventricular-arterial coupling.
2.Experimental study on effects of captopril on renal perfusion in diabetes mellitus rabbits by contrast-enhanced ultrasound
Jian WANG ; Chunsong KANG ; Kailing SHI ; Jiping XUE ; Ruili WANG
Chinese Journal of Ultrasonography 2012;21(9):803-806
Objective To assess the effects of captopril on renal perfusion of diabetic mellitus(DM)rabbits at early stage by contrast-enhanced ultrasound (CEUS).Methods Of 58 rabbits,6 were control group,37 were made as DM model successfully by alloxan and were randomly divided into 4 groups:untreatment group (n =16) and treatment group A,B and C (n =7 averagely).The treatment groups were given captopril(25 mg/kg weight) everyday by intragastric administration after the DM model established and renal pathology appeared Mogensen DN Ⅰ,Ⅱ or / and Ⅲ respectively.The treatment lasted 12 week.Then CEUS was performed on bilateral kidney to observe the renal perfusion,the parameters included:curve ascending slope(K1),time to peak intensity(PIT),peak signal intensity(PSI),area under the curve(AUC) and time to half of peak intensity(HPT).Results At the end of 12 weeks,compared with control group,PIT and HPT delayed,PSI and K1 decreased in untreatment group and group C,AUC of untreatment group increased.Compared with untreatment group,PIT,HPT and AUC decreased,PSI and K1 increased in group A,B and C.Compared with group C,HPT of treatment group A,B decreased.Compared with control group,renal's size increased and the cortex was thickened in untreatment group and group A,B,C.The pathological examination showed:renal were damaged more seriously in untreatment group than that in group A and B.There was no significant difference in Scr and BUN between all groups.Conclusions Assessment of CEUS for renal perfusion of diabetic mellitus rabbits at early stage is feasible and captopril can improve renal perfusion of DM rabbits.
3.Study on renal perfusion of patients with liver cirrhosis by contrast-enhanced ultrasound
Jian WANG ; Chunsong KANG ; Kailing SHI ; Jiping XUE ; Ruili WANG
Chinese Journal of Ultrasonography 2012;21(3):213-216
Objective To assess the renal perfusion of different severity of hepatic cirrhosis by contrast-enhanced ultrasound with time-intensity curve.Methods Forty hepatic cirrhosis patients with normal conventional renal function enrolled the study and were subdivided into Child-Pugh A group ( n =14),Child-Pugh B group ( n =14) and Child-Pugh C group ( n =12).Thirty healthy subjects were selected as the control group.The parameters of perfusion were compared among the groups.The correlations between parameters and score of Child-Pugh were analyzed using Pearson correlation.Results The cirrhosis groups showed a decrease of peak intensity,increase of time to peak,and reduce of area under the curve in the renal cortex( P <0.05).Compared with Child-Pugh A group,the peak intensity decreased in both ChildPugh B and C groups,time to peak increased in Child-Pugh C group( P <0.05 or P <0.01 ).The peak intensity had negative correlation with Child-Pugh score( r =- 0.506,P <0.01 ).Conclusions Contrastenhanced ultrasound combined with time-intensity curve can assess renal perfusion of hepatic cirrhosis quantitatively.The peak intensity was correlated to the severity of cirrhosis.