1.Application research on new technology for on-board medical waste pyrolysis
Zheng WANG ; Junshu HAN ; Lihua WU ; Yajun LIU
Chinese Medical Equipment Journal 2015;36(5):104-106
Objective To explore the theories of medical waste pyrolysis system composition, waste pyrolysis process, flue gas treatment process and etc.Methods The composition and process of pyrolysis treatment system and flue gas cleaning system were studied with the theories of configuration design, physico-chemical analysis, thermodynamics, fluid mechanics and etc.Results The schemes were put forward for on-board pyrolysis furnace and flue gas cleaning system.Conclusion On-board medical waste pyrolysis system can be used to treat the infectious waste in public medical emergencies, and thus is worth popularizing practically.
2.Effect of carvedilol on heart function and glucolipometabolic in elder patients with diastolic heart failure
Yan ZHENG ; Lin MENG ; Junshu DONG ; Jinyi WU
Journal of Jilin University(Medicine Edition) 2006;0(06):-
Objective To discuss the effects of carvedilol on the heart function and glucolipometabolism in elder patients with diastolic heart failure.Methods 76 elder patients with diastolic heart failure were randomly divided into treatment group(n=34) and control group(n=42),all the patients were given routine treatment of diastolic heart failure,the patients in treatment group were given carvediol in addition( from little dose to more ),the course of treatment was 3-6 months.The parameters of the diastolic function of heart before and after treatment in two groups were determined by ultrasonic cardiogram and uninjured cardiodynamic machine.And the levels of fasting blood glucose,triacylglucerol(TG),cholesterol in two groups were detected.Results After treatment the total effective rate in treatment group was higher than that in control group( P
3.Design of on-board medical waste pyrolysis furnace
Junshu HAN ; Lihua WU ; Wenchang ZHANG ; Zheng WANG
Chinese Medical Equipment Journal 2015;36(5):102-103,129
Objective To design an on-vehicle medical waste pyrolysis furnace for the safe disposal of medical wastes, which could disposal 1t wastes each day. Methods A furnace was designed by in-depth research of pyrolysis, calculation analysis in detail, and taking the experimental results and other factors in. The flue gas treatment system of this medical waste pyrolysis furnace was designed through 3T principle.Results This furnace behaved well in configuration, reliability and self support, whose dioxin emission was limited as 0.213 ng/m3.Conclusion The on-vehicle medical waste pyrolysis furnace gains advantages in safety and environment protection, and has a brilliant future in practice.
4.Discrepancy of sulcus-to-sulcus diameter and its relationship with white-to-white diameter in high myopic eyes
Jing, ZHANG ; Huihui, LUO ; Junshu, WU ; Keming, YU
Chinese Journal of Experimental Ophthalmology 2014;32(12):1102-1106
Background Horizontal sulcus-to-sulcus (STS) and white-to-white diameter are important parameters for designing the proper size of collamer implantable contact lens (ICL).Inappropriate size of ICL may induce the complications postoperatively.Several previous studies compare horizontal STS and white-to-white diameter in normal eyes have been reported,but seldom in high myopic eyes.Objective This study was to investigate the discrepancy of STS diameters in 4 axes and analyze the relationship between horizontal STS diameter and white-towhite diameter in high myopia eyes.Methods The STS diameters in 4 axes (45,90,135 and 180 degrees) and the white-to-white diameters were measured in 48 eyes of 26 high myopia patients using the 50 MHz ultrasound biomicroscopy (UBM),the Orbscan-Ⅱ topography system,and the IOL Master,respectively.The mean spherical was (-12.93±3.87) diopters (D) (-8 to-20 D).Statistical evaluation was performed using the one-way ANOVA for comparison of measurement.The agreement of three devices was assessed using the Bland and Altman method.Results The mean STS diameter at 45,90,135 and 180 degrees was (12.06±0.50) mm,(12.27±0.50)mm,(12.03±0.46) mm and (11.84±0.47)mm,respectively.The 90 degree STS was significantly larger than other STS diameters (all at P<0.05).The 180 degrees STS was significantly shorter than other STS diameters (all at P<0.05).However,there was no significant difference between 45 degree STS and 135 degree STS (P=0.817).The mean WTW was (11.56±0.40) mm with Orbscan Ⅱ z topography system and (11.98±0.41) mm with IOLMaster.The WTW measured with Orbscan Ⅱ z was significantly shorter than the 180 degrees STS (t =-4.384,P =0.000).The WTW measured with IOLMaster was significantly larger than the 180 degrees STS (t =2.368,P =0.000).Bland-Altman analysis showed not very well agreement for measurements of WTW,STS between Orbscan Ⅱz and UBM,IOLMaster and UBM,Orbscan Ⅱ z and IOLMaster,the width of 95% confidence interval (CI) were-0.57 to 1.12 mm,-0.96 to 0.67 mm,-0.73 to-0.13 mm,respectively.Conclusions The STS diameters in 4 different axes are not identical with each other in high myopia eyes.The longest STS is in the vertical meridian,the shortest STS is in the horizontal meridian.The WTW diameter measured with both Orbscan Ⅱ z and IOLMaster are not precise for calculating the horizontal STS in high myopia eyes.Three instruments cannot be interchanged for calculating the size of ICL.
5.Development of pyrogenation treatment vehicle of medical wastes
Lihua WU ; Zheng WANG ; Junshu HAN ; Wenchang ZHANG ; Chao WU ; Xiaojun SUN ; Xiangdong CUI ; Changzhong XU
Chinese Medical Equipment Journal 2015;36(5):98-101,106
Objective To develop a medical wastes pyrolysis vehicle for field hospital, countryside hospital and public emergencies.Methods Configuration design, thermodynamics theory, ergonomics and auto control technology were involved in to manufacture open-type compartment, on-board pyrolysis furnace, smoke control system, and pyrolysis furnace control and monitoring system.Results The vehicle passed 7 000 km reliability test, high-low temperature test, smoke emission test and army trials.Conclusion The vehicle behaves well in performances and environment protection, and gains high economic and social benefits.
6.c-Fos expression in visual cortex of infant rhesus monkeys with myopia induced by hyperopic defocus
Junshu WU ; Xiangyin SHA ; Hua ZHENG ; Yinghui LIU ; Jian GE
Chinese Journal of Experimental Ophthalmology 2018;36(11):847-851
Objective To observe c-Fos expression in visual cortex of infant rhesus monkeys with myopia induced by hyperopic defocus and preliminarily investigate the possibility of visual cortex participating in myopia. Methods Eight SPF grade healthy infant rhesus monkeys aged 20 to 30 days were randomly divided into hyperopic defocused group and control group,4 monkeys for each group. The monkeys in hyperopic defocused group wore -3 D spectacle lenses. The monkeys in control group wore 0 D lenses. The monkeys' refractive error,corneal topography, vitreous chamber depth were measured at the start of lens wear and at 2,4,6,8,12 weeks post-treatment. At 12 weeks post-treatment,the visual cortex tissues were removed for c-Fos protein measurement by immunohistochemistry and Western blot assays. The results were analyzed semiquantitatively to compare the differences of c-Fos expression between hyperopic defocused group and control group. The use and care of the animals complied with Regulations for the Administration of Affair Concerning Experimental Animals by State Science and Technology Commission. This study protocol was approved by Ethic Committee of Zhongshan Ophthalmic Center ( No. 2013-014). Results After 12 weeks'lens wear,the vitreous chamber elongation amplitude of hyperopic defocused group monkeys was more obvious than that of the control group ([0.93±0.24]mm vs. [0.72±0.09]mm;t=2.292,P=0.047). The decrease of hyperopic degrees of hyperopic defocused group monkeys was more obvious than that of the control group ([-3.23± 1.36]D vs. [-1.55±0.52]D;t=-3.273,P=0.006). The eyes of hyperopic defocused group monkeys appeared a remarkable myopic shift after treatment. The number of c-Fos immunoreactive neurons was less in the hyperopic defocused group than that in the control group,with a statistically significant difference between them ([1 843±191]/mm2vs. [2 296±503]/mm2;t=2.381,P=0.041). Western blot assay showed that the optical density of c-Fos protein in the hyperopic defocused group was significantly less than that in the control group (0.50±0.17 vs. 0.99± 0.22;t=-4.982,P<0.01). Conclusions Hyperopic defocus,as an abnormal visual stimulus,can induce the onset of myopia in infant rhesus monkeys and inhibit c-Fos expression in visual cortex. Visual cortex may participate in myopia induced by hyperopic defocus.