1.Simultaneous Determination of Phenobarbital, Phenytoin and Carbamazepine in Serum by RP - HPLC
China Pharmacy 1991;0(04):-
OBJECTIVE: To establish a RP - HPLC method for simultaneous determination of the concentrations of phe-nobarbital, phenytoin and carbamazepine in serum.METHODS: Phenobarbital, phenytoin and carbamazepine were extracted from serum with CH2Cl2 and analysed using C18 column with mobile phase consisting of methanol - water(57 : 43); the column temperature was 30℃ ; the detecting wavelength was 254nm and the flow rate was 0.8ml/ min.RESULTS: The calibrating curves of phanobarbital, phenytoin and carbamazepine were linear in the ranges of 2.5 - 40, 2.5-40 and 1.25-20?g/ ml respectively .The within- day and between- day RSDs were less than 10% (n = 5) .CONCLUSION : This method is simple and reliable and suitable for phenobarbital,phanytoin and carbamazepine monitoring.
2.Analysis and Operations of Optimized Design for Man-machine Compatible Work in Equipment Design
Xiaoqiang ZHANG ; Junliang SHEN ; Xicheng YU
Chinese Medical Equipment Journal 2004;0(08):-
From the view of ergonomics study,the importance of optimized design for human-computer coordination work is presented. Through the analysis of probably reasons for the ergonomics accidents in the process of human-computer coordination work,the methods and realization of the optimized design are given out. Furthermore,the studies of human-computer systematization design in preventing the accidents are also discussed.
3.Development of Container Water Station
Xiangfeng HENG ; Zhifang XIA ; Junliang SHEN ; Xicheng YU
Chinese Medical Equipment Journal 2003;0(10):-
Objective To develop a water station that can be loaded to a ship and supply freshwater. Methods The water station comprises the reverse osmosis seawater desalination device, pressure water tank, high pressure water pump, etc, with 40-feet international standard containers as the carrier. Results The water station can produce 80 t freshwater daily, and the quality of produced water conforms to the standards of the state and army for drinking water quality. Conclusion The water station, which has highly-compaction, strong-mobility, excellent-adaptability and high-automaticity, fits for a ship.
4.Development of vest-style first-aid kit
Xicheng YU ; Xiangfeng HENG ; Junliang SHEN ; Xuxia LI
Chinese Medical Equipment Journal 1993;0(05):-
This paper introduces the Vest-style First-aid Kit which are newly developed for PLA.Adopting a vest structure the Vest-style First-aid Kit has the advantages of fully freeing both hands,and being fit for the ship confined space.Basic performance experiments,ergonomics tests and army tryout were performed and the results showed that the vest-style first-aid kit was scientifically designed,and easy to use,suiting the body,obviously saving physical energy.It has a reasonably designed interior medicine layout and can fulfill the requirements of first-aid operations in naval ships.
5.Vertical transmission risk of hepatitis B virus infection in children born to hepatitis B virns-infected parent(s) after in vitro fertilization
Dayong HAO ; Yue YANG ; Junliang ZHAO ; Fangming LU ; Chunyan SHEN ; Xiao ZHANG ; Xingling WANG
Chinese Journal of Infectious Diseases 2016;34(5):271-273
Objective To investigate the risk of hepatitis B virus (HBV) infection in the children born to HBV‐infected parent (s) after in vitro fertilization (IVF) .Methods From January 2008 to December 2013 , in the reproductive medicine center of the Third Affiliated Hospital of Zhengzhou University ,the medical history of 221 mothers by IVF were collected .Inclusion criteria were at least one of the parents was positive for hepatitis B surface antigen (HBsAg) ,and HBV DNA<1 × 104copies/mL . Hepatitis B vaccination status and HBV infection status of children were followed by telephone .Results One hundred and seventy‐two cases were followed up successfully ,and 49cases were lost .Two hundred and twenty‐four cases of children were HBsAg negative ,but one of them showed hepatitis B virus e antibody and hepatitis B virus core antibody positive .Conclusions The vertical transmission risk of HBV infection of children born to HBV‐positive patent(s) by IVF did not increase .
6.Comparison of dose distribution in gamma knife radiotherapy plan, conformal radiotherapy plan and intensity modulated radiotherapy plan for patients with small mass in lung
Ge SHEN ; Weijing ZHANG ; Zhenshan ZHOU ; Zhe JI ; Xiaoping DUAN ; Yanrong LI ; Dapeng DONG ; Min ZHOU ; Junliang WANG ; Yuqin GUO
Chinese Journal of Radiation Oncology 2011;20(1):60-63
Objective To compare dose distribution in gamma knife radiotherapy plan, conformal radiotherapy(CRT)plan and intensity modulated radiotherapy(MRT)plan for patients with small mass in lung, and evaluate their characters. Methods Fourteen patients with small mass in lung participated in the study. Gamma knife radiotherapy plan(plan 1), CRT plan(plan 2)and IMRT plan(plan 3)were made for each mass. The planning target volume(PTV)and the dose include 95% PTV were consistent.Conformal index(CI), homogeneity index(HI), lung V5 ,V10 ,V20 ,V30 and the max dose of esophagus and spinal cord were analyzed. Paired samples t-test was used for comparison between each two plans. Results The CI of the plan 1,2 and 3 were 0. 58,0. 46 and 0. 63, respectively. CI of the plan 1 > that of the plan 2 (t= -3.95,P =0.000),plan 3 > plan 2(t = -6.01 ,P =0.000),plan 1 =plan 3(t =1.64,P =0.116);HI of the plan 1,2 and 3 were 1.66,1.10 and 1.07 respectively. HI of the plan 1 > plan 2 ,plan 1 > plan 3(t= -20.52,21.41 respectively, both P=0. 000),plan 2 = plan 3(t= -1.08,P=0.294). The wholelung V5 ,V10 ,V20 and V30 were 10.0% ,5.6% ,2. 4% and 1.2%, respectively, in plan 1 ;20. 2% ,13. 4%,6. 9% ,3.0%, respectively, in plan 3; and 26. 5%, 18. 0%, 11.4% and 4. 6%, respectively, in plan 2.The V5, V10, V20 and V 30 of the plan 1 < in plan 2(t = 9. 68,8. 41,5. 45,5. 14, all P = 0. 000), the V5,V10,V20 and V30 of the plan 1 < in plan 3(t=7.58,8.95,6. 15,4.78, respectively, all P=0.000),the V5 ,V10, V20andV30 oftheplan2 > inplan3(t =9. 71,5. 91,4. 13,3.91, respectively, allP =0.000).The max dose of esophagus in plan 1 ,2 and 3 were 24.93 ± 21.54, 31.90 ± 18. 75, 29. 19 ± 23.09 Gy,respectively, plan 1 < plan 2(t = -2. 71 ,P=0.013),plan 1 = plan 3(t = - 1.49,P =0. 152),plan 2 =plan 3(t = 1.35, P = 0. 193). The max dose of spinal cord in plan 1,2 and 3 were 12.07 ± 10. 67,17.70 ±11.35 and 8.92 :± 10. 04 Gy, respectively, plan 2 > plan 1 >plan 3(t = -2. 38,2. 29,4. 83,P=0. 1027,0.033,0.000);All three plans of each mass meet the needs that the max dose of the esophagus≤60 Gy and the max dose of spinal cord ≤40 Gy. Conclusions The dose of the normal lung was lower, but the HI and the max dose of spinal cord were higher in Gamma knife radiotherapy plan than those in the CRT and the IMRT plan of the small mass in lung.
7.A prospective multicenter and real-world study on the diagnostic value of combination of number connection test-B and line tracing test in mild hepatic encephalopathy
Junqing YAN ; Hongmei ZU ; Jing WANG ; Xiaoqing GUO ; Xiaoyan LI ; Shanghao LIU ; Huiling XIANG ; Zhaolan YAN ; Tong DANG ; Haiying WANG ; Jia SUN ; Lei HUANG ; Fanping MENG ; Qingge ZHANG ; Guo ZHANG ; Yan HUANG ; Shaoqi YANG ; Shengjuan HU ; Jigang RUAN ; Yiling LI ; Chuang LEI ; Ying SONG ; Zhangshu QU ; Ruichun SHI ; Qin LIU ; Yijun LIU ; Qiaohua YANG ; Xuelan ZHAO ; Caiyan ZHAO ; Chenxi WU ; Qian SHEN ; Manqun WU ; Yayuan LIU ; Dongmei YAN ; Chuan LIU ; Junliang FU ; Xiaolong QI
Chinese Journal of Digestion 2022;42(10):659-666
Objective:To investigate the diagnostic value of independent and combined subtests of the psychometric hepatic encephalopathy score (PHES) in mild hepatic encephalopathy(MHE) of patients with liver cirrhosis, so as to optimize the PHES.Methods:This was a prospective, multicenter and real-world study which was sponsored by the National Clinical Research Center of Infectious Diseases and the Portal Hypertension Consortium. Twenty-six hospitals from 13 provinces, autonomous regions and municipalities countrywide participated in this study, induding Tianjin Third Central Hospital, the Fourth People′s Hospital of Qinghai Province, the Second Affiliated Hospital of Baotou Medical College, the Third People′s Hospital of Taiyuan, the Fifth Medical Center of PLA General Hospital and so on. From October 2021 to February 2022, outpatients and hospitalized patients with liver cirrhosis and no obvious hepatic encephalopathy were consecutively enrolled. All patients received 5 PHES subjects in the same order: number connection test(NCT)-A, NCT-B, digit symbol test(DST), line tracing test(LTT) and serial dotting test(SDT), and the scores were calculated. The total score of PHES <-4 was taken as the cut-off value for diagnosing MHE. Compare the differences in each subtest between MHE group and non-MHE group. Receiver operating characteristic curve(ROC) and area under the curve(AUC) was performed to assess the diagnostic value of independent and combined subtests in MHE. Mann-Whitney U test and DeLong test were used for statistical analysis. Results:A total of 581 patients with liver cirrhosis were enrolled, 457 were diagnosed as MHE, and the incidence of MHE was 78.7%. The results of NCT-A, NCT-B, SDT, LTT, DST of MHE group were 60.00 s(47.01 s, 88.00 s), 90.45 s(69.32 s, 125.35 s), 74.00 s(57.65 s, 96.60 s), 74.72(60.00, 98.61) and 27.00(20.00, 36.00), respectively. Compared those of non-MHE group(34.00 s(29.15 s, 44.48 s), 50.00 s(40.98 s, 60.77 s), 50.00 s(41.07 s, 63.03 s), 46.23(38.55, 59.42) and 42.00(34.00, 50.75)), the differences were statistically significant( Z=12.37, 12.98, 9.83, 11.56, 10.66; all P<0.001). The AUC(95% confidence interval(95% CI)) of subtests of PHES NCT-B, NCT-A, LTT, DST and SDT alone in MHE diagnosis were 0.880(0.849 to 0.910), 0.862(0.828 to 0.896), 0.838(0.799 to 0.877), 0.812(0.772 to 0.851) and 0.788(0.743 to 0.832), respectively. The combination of 2 PHES subtests significantly increased the diagnostic efficacy. Among them the diagnostic efficacy of the combination of NCT-B and LTT was the best, the AUC(95% CI) was 0.924(0.902 to 0.947), the specificity was 91.9% and the sensitivity was 79.2%, which was better than a single PHES subtest (NCT-A, NCT-B, SDT, LTT and DST) and the combination of NCT-A and DST(AUC was 0.879, 95% CI0.847 to 0.910) which was recommended by guidelines on the management of hepatic encephalopathy in cirrhosis, the differences were statistically significant ( Z=3.78, 3.83, 5.57, 5.51, 5.38, 2.93; all P<0.01). Furthermore, compared between the combination of NCT-B and LTT and the combination of 3 subests of PHES, only the diagnostic efficacy of combination of NCT-B, LTT and SDT (AUC was 0.936, 95% CI 0.916 to 0.956) was better than that of the combination of NCT-B and LTT, the difference was statistically significant( Z=2.32, P=0.020). Conclusion:Based on the diagnostic efficacy and clinical feasibility of PHES subtests and their combinations, the combination of NCT-B and LTT is recommended for the diagnosis of MHE.
8.Three-dimensional finite element analysis of short implant for mandibular molar with insufficient vertical bone
Tianqi Zhao ; Bingqing Xie ; Jie Shen ; Junliang Chen ; Kuncai Li ; Yun He
Acta Universitatis Medicinalis Anhui 2022;57(9):1508-1512
Objective:
To explore the biomechanical characteristics of short implants with different diameters in mandibular molars with severe jaw absorption, and to provide theoretical basis for the application of short implants in mandibular molar area.
Methods:
CBCT data of patient were imported into Mimics and 3-Matic, and the finite element model of mandibular second molar repaired with short implant with diameter of 5.5 mm or 6.5 mm and length of 7 mm was established. The data were imported into three-dimensional finite element analysis software Marc Mentat, and high or low density bone was set up. An axial or buccal load of 150 N was applied to simulate clinical situation. A total of 8 models were established. Cortical bone stress, cancellous bone strain and implant displacement were calculated and analyzed.
Results:
The cortical bone stress was concentrated in the neck of implant, and the cancellous bone strain was mainly distributed in the apical area of implant. The maximum values of cortical bone stress, cancellous bone strain and implant displacement were higher in buccal loading model than those in axial loading model, and they were higher in low density bone model than those in high density bone model under the same conditions. When the 5.5 mm diameter implant was loaded in buccal direction and the surrounding bone density was low, the maximum strain of cancellous bone was greater than the upper limit of physiological absorption of bone tissue 3 000 μstrain.
Conclusion
The application of short implants in mandibular molars with insufficient vertical bone mass is a feasible restoration scheme. But for patients with low bone mineral density, large diameter short implants can be appropriately selected, and the occlusal area and the cusp inclination can be appropriately reduced, so as to reduce the lateral force and obtain the stability and success of the implant in the short and long term.
9.Impact of different diagnostic criteria for assessing mild micro-hepatic encephalopathy in liver cirrhosis: an analysis based on a prospective, multicenter, real-world study
Xiaoyan LI ; Shanghao LIU ; Chuan LIU ; Hongmei ZU ; Xiaoqing GUO ; Huiling XIANG ; Yan HUANG ; Zhaolan YAN ; Yajing LI ; Jia SUN ; Ruixin SONG ; Junqing YAN ; Qing YE ; Fei LIU ; Lei HUANG ; Fanping MENG ; Xiaoning ZHANG ; Shaoqi YANG ; Shengjuan HU ; Jigang RUAN ; Yiling LI ; Ningning WANG ; Huipeng CUI ; Yanmeng WANG ; Chuang LEI ; Qinghai WANG ; Hongling TIAN ; Zhangshu QU ; Min YUAN ; Ruichun SHI ; Xiaoting YANG ; Dan JIN ; Dan SU ; Yijun LIU ; Ying CHEN ; Yuxiang XIA ; Yongzhong LI ; Qiaohua YANG ; Huai LI ; Xuelan ZHAO ; Zemin TIAN ; Hongji YU ; Xiaojuan ZHANG ; Chenxi WU ; Zhijian WU ; Shengqiang LI ; Qian SHEN ; Xuemei LIU ; Jianping HU ; Manqun WU ; Tong DANG ; Jing WANG ; Xianmei MENG ; Haiying WANG ; Zhenyu JIANG ; Yayuan LIU ; Ying LIU ; Suxuan QU ; Hong TAO ; Dongmei YAN ; Jun LIU ; Wei FU ; Jie YU ; Fusheng WANG ; Xiaolong QI ; Junliang FU
Chinese Journal of Hepatology 2023;31(9):961-968
Objective:To compare the differences in the prevalence of mild micro-hepatic encephalopathy (MHE) among patients with cirrhosis by using the psychometric hepatic encephalopathy score (PHES) and the Stroop smartphone application (Encephal App) test.Methods:This prospective, multi-center, real-world study was initiated by the National Clinical Medical Research Center for Infectious Diseases and the Portal Hypertension Alliance and registered with International ClinicalTrials.gov (NCT05140837). 354 cases of cirrhosis were enrolled in 19 hospitals across the country. PHES (including digital connection tests A and B, digital symbol tests, trajectory drawing tests, and serial management tests) and the Stroop test were conducted in all of them. PHES was differentiated using standard diagnostic criteria established by the two studies in China and South Korea. The Stroop test was evaluated based on the criteria of the research and development team. The impact of different diagnostic standards or methods on the incidence of MHE in patients with cirrhosis was analyzed. Data between groups were differentiated using the t-test, Mann-Whitney U test, and χ2 test. A kappa test was used to compare the consistency between groups. Results:After PHES, the prevalence of MHE among 354 cases of cirrhosis was 78.53% and 15.25%, respectively, based on Chinese research standards and Korean research normal value standards. However, the prevalence of MHE was 56.78% based on the Stroop test, and the differences in pairwise comparisons among the three groups were statistically significant (kappa = -0.064, P < 0.001). Stratified analysis revealed that the MHE prevalence in three groups of patients with Child-Pugh classes A, B, and C was 74.14%, 83.33%, and 88.24%, respectively, according to the normal value standards of Chinese researchers, while the MHE prevalence rates in three groups of patients with Child-Pugh classes A, B, and C were 8.29%, 23.53%, and 38.24%, respectively, according to the normal value standards of Korean researchers. Furthermore, the prevalence rates of MHE in the three groups of patients with Child-Pugh grades A, B, and C were 52.68%, 58.82%, and 73.53%, respectively, according to the Stroop test standard. However, among the results of each diagnostic standard, the prevalence of MHE showed an increasing trend with an increasing Child-Pugh grade. Further comparison demonstrated that the scores obtained by the number connection test A and the number symbol test were consistent according to the normal value standards of the two studies in China and South Korea ( Z = -0.982, -1.702; P = 0.326, 0.089), while the other three sub-tests had significant differences ( P < 0.001). Conclusion:The prevalence rate of MHE in the cirrhotic population is high, but the prevalence of MHE obtained by using different diagnostic criteria or methods varies greatly. Therefore, in line with the current changes in demographics and disease spectrum, it is necessary to enroll a larger sample size of a healthy population as a control. Moreover, the establishment of more reliable diagnostic scoring criteria will serve as a basis for obtaining accurate MHE incidence and formulating diagnosis and treatment strategies in cirrhotic populations.