1.Report on the Workshop "Health Literacy Primer: Enhancing Patients' Skills to Promote Their Good Health"
Jun MIYATA ; Naoto SAKAMOTO ; Mako NIKAWA ; Seina SHINNO ; Yasumichi SHINNO ; Hirohiko OHAMA ; Yusuke SUZUKI ; Osamu MUTO ; Naohiro KONOSHITA ; Kazuko KUSUKAWA
An Official Journal of the Japan Primary Care Association 2019;42(1):70-74
A workshop entitled "Health Literacy Primer: Enhancing Patients' Skills to Promote Their Good Health" was held during the 30th Family Medicine Summer Seminar for medical students and residents by the Japanese Primary Care Association. Participants carried out four group activities to learn about health literacy. First, participants watched a skit of a conversation between two women with low health literacy to recognize the importance of promoting health literacy among citizens. Second, they practiced evaluating the reliability of health information based on the Health on the Net (HON) Code and "How to read health news" published by the British National Health Service. Third, they conducted medical interviews with patients who had brought documents containing questionable health information. Fourth, they practiced interviewing citizens with a low literacy in healthcare matters using the "teach back" technique and "Ask Me 3" questions. Many participants stated that our workshop was satisfying and understandable. We think it is necessary to hold such workshops to establish the concept of health literacy in our country, especially in the field of healthcare. In this report, we summarize the content of our workshop, and discuss future objectives for spreading and developing health literacy in Japan.
2.Transoral Robotic-Assisted Neurosurgery for Skull Base and Upper Spine Lesions
Jun MUTO ; Ichiro TATEYA ; Hirofumi NAKATOMI ; Ichiro UYAMA ; Yuichi HIROSE
Neurospine 2024;21(1):106-115
Objective:
The application of the da Vinci Surgical System in neurosurgery is limited due to technical difficulties requiring precise maneuvers and small instruments. This study details the advantages and disadvantages of robotics in neurosurgery and the reachable range of the transoral approach to lesions of the skull base and upper cervical spine.
Methods:
In a cadaver study, the da Vinci Xi robot, lacking haptic feedback, was utilized for sagittal and coronal approaches on 5 heads, facilitating dura suturing in 3, with a 30°-angled drill for bone removal.
Results:
Perfect exposure of all the nasopharyngeal sites, clivus, sellar, and choana, including the bilateral eustachian tubes, was achieved without any external incisions using this palatal split approach of transoral robotic surgery. The time required to perform a single stitch, knot, and complete single suture in robotic suturing of deep-seated were significantly less compared to manual suturing via the endonasal approach.
Conclusion
This is the first report to show the feasibility of suturing the dural defect in deep-seated lesions transorally and revealed that the limit of reach in the coronal plane via a transoral approach with incision of the soft palate is the foramen ovale. This preclinical investigation also showed that the transoral robotic approach is feasible for lesions extending from the sellar to the C2 in the sagittal plane. Refinement of robotic instruments for specific anatomic sites and future neurosurgical studies are needed to further demonstrate the feasibility and effectiveness of this system in treating benign and malignant skull base lesions.
3.Transoral Robotic-Assisted Neurosurgery for Skull Base and Upper Spine Lesions
Jun MUTO ; Ichiro TATEYA ; Hirofumi NAKATOMI ; Ichiro UYAMA ; Yuichi HIROSE
Neurospine 2024;21(1):106-115
Objective:
The application of the da Vinci Surgical System in neurosurgery is limited due to technical difficulties requiring precise maneuvers and small instruments. This study details the advantages and disadvantages of robotics in neurosurgery and the reachable range of the transoral approach to lesions of the skull base and upper cervical spine.
Methods:
In a cadaver study, the da Vinci Xi robot, lacking haptic feedback, was utilized for sagittal and coronal approaches on 5 heads, facilitating dura suturing in 3, with a 30°-angled drill for bone removal.
Results:
Perfect exposure of all the nasopharyngeal sites, clivus, sellar, and choana, including the bilateral eustachian tubes, was achieved without any external incisions using this palatal split approach of transoral robotic surgery. The time required to perform a single stitch, knot, and complete single suture in robotic suturing of deep-seated were significantly less compared to manual suturing via the endonasal approach.
Conclusion
This is the first report to show the feasibility of suturing the dural defect in deep-seated lesions transorally and revealed that the limit of reach in the coronal plane via a transoral approach with incision of the soft palate is the foramen ovale. This preclinical investigation also showed that the transoral robotic approach is feasible for lesions extending from the sellar to the C2 in the sagittal plane. Refinement of robotic instruments for specific anatomic sites and future neurosurgical studies are needed to further demonstrate the feasibility and effectiveness of this system in treating benign and malignant skull base lesions.
4.Transoral Robotic-Assisted Neurosurgery for Skull Base and Upper Spine Lesions
Jun MUTO ; Ichiro TATEYA ; Hirofumi NAKATOMI ; Ichiro UYAMA ; Yuichi HIROSE
Neurospine 2024;21(1):106-115
Objective:
The application of the da Vinci Surgical System in neurosurgery is limited due to technical difficulties requiring precise maneuvers and small instruments. This study details the advantages and disadvantages of robotics in neurosurgery and the reachable range of the transoral approach to lesions of the skull base and upper cervical spine.
Methods:
In a cadaver study, the da Vinci Xi robot, lacking haptic feedback, was utilized for sagittal and coronal approaches on 5 heads, facilitating dura suturing in 3, with a 30°-angled drill for bone removal.
Results:
Perfect exposure of all the nasopharyngeal sites, clivus, sellar, and choana, including the bilateral eustachian tubes, was achieved without any external incisions using this palatal split approach of transoral robotic surgery. The time required to perform a single stitch, knot, and complete single suture in robotic suturing of deep-seated were significantly less compared to manual suturing via the endonasal approach.
Conclusion
This is the first report to show the feasibility of suturing the dural defect in deep-seated lesions transorally and revealed that the limit of reach in the coronal plane via a transoral approach with incision of the soft palate is the foramen ovale. This preclinical investigation also showed that the transoral robotic approach is feasible for lesions extending from the sellar to the C2 in the sagittal plane. Refinement of robotic instruments for specific anatomic sites and future neurosurgical studies are needed to further demonstrate the feasibility and effectiveness of this system in treating benign and malignant skull base lesions.
5.Transoral Robotic-Assisted Neurosurgery for Skull Base and Upper Spine Lesions
Jun MUTO ; Ichiro TATEYA ; Hirofumi NAKATOMI ; Ichiro UYAMA ; Yuichi HIROSE
Neurospine 2024;21(1):106-115
Objective:
The application of the da Vinci Surgical System in neurosurgery is limited due to technical difficulties requiring precise maneuvers and small instruments. This study details the advantages and disadvantages of robotics in neurosurgery and the reachable range of the transoral approach to lesions of the skull base and upper cervical spine.
Methods:
In a cadaver study, the da Vinci Xi robot, lacking haptic feedback, was utilized for sagittal and coronal approaches on 5 heads, facilitating dura suturing in 3, with a 30°-angled drill for bone removal.
Results:
Perfect exposure of all the nasopharyngeal sites, clivus, sellar, and choana, including the bilateral eustachian tubes, was achieved without any external incisions using this palatal split approach of transoral robotic surgery. The time required to perform a single stitch, knot, and complete single suture in robotic suturing of deep-seated were significantly less compared to manual suturing via the endonasal approach.
Conclusion
This is the first report to show the feasibility of suturing the dural defect in deep-seated lesions transorally and revealed that the limit of reach in the coronal plane via a transoral approach with incision of the soft palate is the foramen ovale. This preclinical investigation also showed that the transoral robotic approach is feasible for lesions extending from the sellar to the C2 in the sagittal plane. Refinement of robotic instruments for specific anatomic sites and future neurosurgical studies are needed to further demonstrate the feasibility and effectiveness of this system in treating benign and malignant skull base lesions.
6.Transoral Robotic-Assisted Neurosurgery for Skull Base and Upper Spine Lesions
Jun MUTO ; Ichiro TATEYA ; Hirofumi NAKATOMI ; Ichiro UYAMA ; Yuichi HIROSE
Neurospine 2024;21(1):106-115
Objective:
The application of the da Vinci Surgical System in neurosurgery is limited due to technical difficulties requiring precise maneuvers and small instruments. This study details the advantages and disadvantages of robotics in neurosurgery and the reachable range of the transoral approach to lesions of the skull base and upper cervical spine.
Methods:
In a cadaver study, the da Vinci Xi robot, lacking haptic feedback, was utilized for sagittal and coronal approaches on 5 heads, facilitating dura suturing in 3, with a 30°-angled drill for bone removal.
Results:
Perfect exposure of all the nasopharyngeal sites, clivus, sellar, and choana, including the bilateral eustachian tubes, was achieved without any external incisions using this palatal split approach of transoral robotic surgery. The time required to perform a single stitch, knot, and complete single suture in robotic suturing of deep-seated were significantly less compared to manual suturing via the endonasal approach.
Conclusion
This is the first report to show the feasibility of suturing the dural defect in deep-seated lesions transorally and revealed that the limit of reach in the coronal plane via a transoral approach with incision of the soft palate is the foramen ovale. This preclinical investigation also showed that the transoral robotic approach is feasible for lesions extending from the sellar to the C2 in the sagittal plane. Refinement of robotic instruments for specific anatomic sites and future neurosurgical studies are needed to further demonstrate the feasibility and effectiveness of this system in treating benign and malignant skull base lesions.
7.Introduction of Laparoscopic Partial Liver Resection:Analysis of the First 60 Consecutive Cases
Masaomi ICHINOKAWA ; Koichi ONO ; Katsuhiko MURAKAWA ; Hiroki NIWA ; Hiroyuki YAMAMOTO ; Hideyuki WADA ; Jun MUTO ; Kohei KATO ; Tatsuya YOSHIOKA ; Joe MATSUMOTO ; Setsuyuki OHTAKE
Journal of the Japanese Association of Rural Medicine 2017;66(2):103-108
Safe introduction of laparoscopic partial liver resection (LPLR) requires the selection of appropriate cases not exceeding the surgeon's skills as well as standardization of surgical procedures. After introduction at our institution, 60 LPLR procedures were performed between April 2010 and May 2016. To identify indices for case selection, short-term perioperative parameters were analyzed, including operative time, blood loss, postoperative complications, and postoperative hospital stay. Operative time was significantly shorter in the last 30 cases compared with the first 30 cases (182.5 min vs. 253 min; p=0.023) and in 16 cases involving the left lobe (S2-4) compared with 44 cases involving the right lobe (S1, S5-8; 148.5 min vs. 246 min; p=0.004). Blood loss was significantly less (0 mL vs. 50 mL; p=0.028) and operative time was significantly shorter (185 min vs. 250 min; p=0.048) in 27 cases with tumor diameter <2.5 cm compared with 33 cases with tumor diameter ≥ 2.5 cm. Operative time tended to be longer in 9 cases of multiple-site resection compared with 51 cases of single-site resection (207 min vs. 260 min; p=0.085). BMI, pathology, and hepatitis virus status showed no significant difference in perioperative short-term results. For the introduction of LPLR, it may be preferable to select cases located in the left lobe with a tumor diameter <2.5 cm and to accumulate a certain amount of experience in similar cases first.
8.Advancements and Challenges in Robot-Assisted Bone Processing in Neurosurgical Procedures
Yoshihiro KITAHAMA ; Hiroo SHIZUKA ; Yuto NAKANO ; Yukoh OHARA ; Jun MUTO ; Shuntaro TSUCHIDA ; Daisuke MOTOYAMA ; Hideaki MIYAKE ; Katsuhiko SAKAI
Neurospine 2024;21(1):97-103
Objective:
Practical applications of nerve decompression using neurosurgical robots remain unexplored. Our ongoing research and development initiatives, utilizing industrial robots, aim to establish a secure and efficient neurosurgical robotic system. The principal objective of this study was to automate bone grinding, which is a pivotal component of neurosurgical procedures.
Methods:
To achieve this goal, we integrated an endoscope system into a manipulator and conducted precision bone machining using a neurosurgical drill, recording the grinding resistance values across 3 axes. Our study encompassed 2 core tasks: linear grinding, such as laminectomy, and cylindrical grinding, such as foraminotomy, with each task yielding unique measurement data.
Results:
In linear grinding, we observed a proportional increase in grinding resistance values in the machining direction with acceleration. This observation suggests that 3-axis resistance measurements are a valuable tool for gauging and predicting deep cortical penetration. However, problems occurred in cylindrical grinding, and a significant error of 10% was detected. The analysis revealed that multiple factors, including the tool tip efficiency, machining speed, teaching methods, and deflection in the robot arm and jig joints, contributed to this error.
Conclusion
We successfully measured the resistance exerted on the tool tip during bone machining with a robotic arm across 3 axes. The resistance ranged from 3 to 8 Nm, with the measurement conducted at a processing speed approximately twice that of manual surgery performed by a surgeon. During the simulation of foraminotomy under endoscopic grinding conditions, we encountered a -10% error margin.
9.Advancements and Challenges in Robot-Assisted Bone Processing in Neurosurgical Procedures
Yoshihiro KITAHAMA ; Hiroo SHIZUKA ; Yuto NAKANO ; Yukoh OHARA ; Jun MUTO ; Shuntaro TSUCHIDA ; Daisuke MOTOYAMA ; Hideaki MIYAKE ; Katsuhiko SAKAI
Neurospine 2024;21(1):97-103
Objective:
Practical applications of nerve decompression using neurosurgical robots remain unexplored. Our ongoing research and development initiatives, utilizing industrial robots, aim to establish a secure and efficient neurosurgical robotic system. The principal objective of this study was to automate bone grinding, which is a pivotal component of neurosurgical procedures.
Methods:
To achieve this goal, we integrated an endoscope system into a manipulator and conducted precision bone machining using a neurosurgical drill, recording the grinding resistance values across 3 axes. Our study encompassed 2 core tasks: linear grinding, such as laminectomy, and cylindrical grinding, such as foraminotomy, with each task yielding unique measurement data.
Results:
In linear grinding, we observed a proportional increase in grinding resistance values in the machining direction with acceleration. This observation suggests that 3-axis resistance measurements are a valuable tool for gauging and predicting deep cortical penetration. However, problems occurred in cylindrical grinding, and a significant error of 10% was detected. The analysis revealed that multiple factors, including the tool tip efficiency, machining speed, teaching methods, and deflection in the robot arm and jig joints, contributed to this error.
Conclusion
We successfully measured the resistance exerted on the tool tip during bone machining with a robotic arm across 3 axes. The resistance ranged from 3 to 8 Nm, with the measurement conducted at a processing speed approximately twice that of manual surgery performed by a surgeon. During the simulation of foraminotomy under endoscopic grinding conditions, we encountered a -10% error margin.
10.Advancements and Challenges in Robot-Assisted Bone Processing in Neurosurgical Procedures
Yoshihiro KITAHAMA ; Hiroo SHIZUKA ; Yuto NAKANO ; Yukoh OHARA ; Jun MUTO ; Shuntaro TSUCHIDA ; Daisuke MOTOYAMA ; Hideaki MIYAKE ; Katsuhiko SAKAI
Neurospine 2024;21(1):97-103
Objective:
Practical applications of nerve decompression using neurosurgical robots remain unexplored. Our ongoing research and development initiatives, utilizing industrial robots, aim to establish a secure and efficient neurosurgical robotic system. The principal objective of this study was to automate bone grinding, which is a pivotal component of neurosurgical procedures.
Methods:
To achieve this goal, we integrated an endoscope system into a manipulator and conducted precision bone machining using a neurosurgical drill, recording the grinding resistance values across 3 axes. Our study encompassed 2 core tasks: linear grinding, such as laminectomy, and cylindrical grinding, such as foraminotomy, with each task yielding unique measurement data.
Results:
In linear grinding, we observed a proportional increase in grinding resistance values in the machining direction with acceleration. This observation suggests that 3-axis resistance measurements are a valuable tool for gauging and predicting deep cortical penetration. However, problems occurred in cylindrical grinding, and a significant error of 10% was detected. The analysis revealed that multiple factors, including the tool tip efficiency, machining speed, teaching methods, and deflection in the robot arm and jig joints, contributed to this error.
Conclusion
We successfully measured the resistance exerted on the tool tip during bone machining with a robotic arm across 3 axes. The resistance ranged from 3 to 8 Nm, with the measurement conducted at a processing speed approximately twice that of manual surgery performed by a surgeon. During the simulation of foraminotomy under endoscopic grinding conditions, we encountered a -10% error margin.