1.Studies on Furrow Flat Planting Cultivation Techniques of Mongolian Milkvetch (Astragalus mongholicus)
Xiaoling BAI ; Juming WANG ; Lin WEI
Chinese Traditional and Herbal Drugs 1994;0(03):-
By comparing three cultivation techniques of Astragalus mongholicus, i. e. direct seeding, furrow erectplanting and furrow flat planting, it was found that furrow flat planting is the optimum technique. Its yield onplain ground was 1. 26kg/m' and 0. 96kg/m_2 on mountainous area- Root of the plant was longer, thicker andheavier than that produced hy other cultivation techniqlles. Its input/output ratio was l s l2' 94 on plaingrounfl and l: 9. 95 on n1ollntainous area. Therefore,it can be considered as a scientifically justifiable,economically technique for the cultivation of A. mongholicus on both plain ground and mountainous regions.
2.Influence of Four Kinds of Material on the Results of Two Kinds of D-dimer Detection Reagent Assay
Yun ZHANG ; Min HUANG ; Xing GAO ; Min LIU ; Nuohan LIU ; Juming BAI ; Qiangyuan ZHAO
Journal of Modern Laboratory Medicine 2014;(5):164-166
Objective To observe the influence of triglyceride(TG),hemoglobin(HGB),total bilirubin(TBIL)and rheumatoid factor(RF)on the results of two kinds of D-dimer detection reagent assay.Methods Five samples were prepared into series with 2,4,6,8 and 10 mmol/L triglyceride by adding fat emulsion.Five samples were prepared into series with 1,2,3,4 and 5 g/L of hemolysis degree by adding hemoglobin solution.Five samples were prepared into series with 20,40,60,80 and 100μmol/L total bilirubin by adding bilirubin standard preparation.Ten samples were prepared into rheumatoid factor levels be-tween 0~150 IU/L by adding rheumatoid factor standard solution.Simultaneously with D-dimer detection reagent and D-di-mer HS detection reagent for testing,each sample was measured two times and the results averaged.Results When TG≤2 mmol/L,the D-dimer reagents without interference,and TG≥4 mmol/L,the D-dimer reagents due to “SD baseline data out of range”couldn’t be detected.TG≤10 mmol/L,for D-dimer HS reagents was without interference.When HGB≥1 g/L, the D-dimer reagents due to“SD baseline data out of range”couldn’t be detected.HGB≤4 g/L,for D-dimer HS reagents was without interference.When hemoglobin levels was equal to 5 g/L,the D-dimer HS reagents test results false increased about 30.4%.With total bilirubin concentration increases,D-dimer and D-dimer HS reagents test results were false increase, showed amplitude by a power law,and the two reagents increased consistency.Preparation a series of pooled plasma of rheu-matoid factor levels in 0~150 IU/L,D-dimer test results reagent falsely elevated levels of rheumatoid factor with a linear correlation (Y=59.31X+50.43,R2=0.998).When RF≤150 IU/L,the D-dimer HS reagents was without interference. Conclusion Triglyceride,hemoglobin,total bilirubin and rheumatoid factor may interfere D-dimer testing process,icterus and severe hemolysis will interfere D-dimer HS testing process.D-dimer HS reagents against interfere exceed D-dimer rea-gents.When D-dimer test results does not match with clinicians determine,the influence ofinterfering substances should be considered.