1.The Standards of Skeletal Maturity of Hand and Wrist for Chinese-China 05. III. The Secular Trend of Skeletal Development in Chinese Children
Shaoyan ZHANG ; Jiqing HUA ; Lijuan LIU
Chinese Journal of Sports Medicine 1982;0(02):-
Objective Due to the accelerated growth of Chinese children, the secular trend of accelerated skeletal development was observed in this study in order to provide the evidence for using the standards of skeletal maturity in reason.Methods The subjects were the children from two skeletal development surveys in 1980s and 2000s. The appearance age and fusion age of ossification centers in hand and wrist were calculated using the probit regression analysis, and the skeletal ages of children from the survey in 2000s were estimated by CHN method. The CHN skeletal ages were compared with calendar ages. Results Compared with the children in 1960s, the appearance ages and fusion ages of the ossification centers were all advanced in children in 1980s. Compared with the children in 1980s, the metacarpals and phalanges of children in 2000s were advanced by 0.5-1.0 year at age of appearance of ossification centers and 1.0 year in boys and 1.0-1.5 years in girls at the ages of fusion ossification centers. The ages of complete ossification of radius and ulna in children in 2000s were advanced by 0.4 year in boys and 0.3 year in girls. The differences between CHN skeletal age and chronological age of all age groups in 2000s were 0.3-1.1 year in boys and 0.2-1.0 year in girls. Conclusions In the last 40 years, the secular trend of accelerated skeletal development was presented in Chinese children. It should be cautious to estimate the contemporary Chinese children when using the skeletal norms of 1960s or 1980s.
2.Application of iodine contrast agent optimization protocol with fixed injection time in triple-rule-out CT examination of chest pain
Li HUA ; Jiqing ZHANG ; Shan ZHANG ; Caihui ZHANG ; Zhaoxia WANG ; Yueying ZHANG
Chinese Critical Care Medicine 2019;31(5):582-587
Objective To investigate the feasibility of using optimized protocol of iodine contrast agent with fixed injection time in triple-rule-out CT examination of acute chest pain patients. Methods A prospective study was conducted. The patients who underwent triple-rule-out CT examination of acute chest pain at the Second Hospital of Shanxi Medical University from September 2017 to June 2018 were enrolled. According to the patient's body mass index (BMI), they were divided into BMI ≤ 23 kg/m2 group and BMI > 23 kg/m2 group. The patients in each group were subdivided into two subgroups according to the random number table, and they were given two iodine contrast injection protocols with fixed injection time (14 s). Protocol 1 was performed with 55 mL of total iodinated contrast media: iodinated contrast media was first injected at 5.0 mL/s for 8 s, followed by the same contrast media injection at 2.5 mL/s for 6 s, finally followed by injection of 40 mL of saline at a rate of 2.5 mL/s. Protocol 2 with 60 mL of total iodinated contrast media: iodinated contrast media was first injected at 5.0 mL/s for 10 s, followed by the same contrast media injection at 2.5 mL/s for 4 s, finally followed by injection of 40 mL of saline at a rate of 2.5 mL/s. The primary and objective evaluation was conducted on the image quality of the patients' blood vessels in different segments. The primary score, CT value and contrast-to-noise ratio (CNR) of the pulmonary artery, coronary artery, aorta and total effective radiation dose for the examination were recorded. Results A total of 92 patients were enrolled in the analysis. There were 44 patients in BMI≤ 23 kg/m2 group, in which 22 patients received in protocol 1 and protocol 2, 48 patients in BMI > 23 kg/m2 group, in which 24 patients in protocol 1 and protocol 2, respectively. There was no significant difference in the effective radiation dose between the two subgroups receiving different injection protocols in different BMI groups (mSv: 6.7±1.1 vs. 6.5±0.8 between protocol 1 and protocol 2 in BMI ≤ 23 kg/m2 group; 7.8±1.0 vs. 8.0±1.1 between protocol 1 and protocol 2 in BMI > 23 kg/m2 group, both P > 0.05). In BMI ≤ 23 kg/m2 group, the CT value, CNR and primary scores of pulmonary artery images in patients receiving protocol 2 were significantly higher than those receiving protocol 1 [CT value (HU): 584±110 vs. 472±86 for main pulmonary artery, 561±93 vs. 467±78 for left pulmonary artery, 555±91 vs. 472±83 for right pulmonary artery; CNR: 24.2±7.5 vs. 18.7±4.6 for main pulmonary artery, 23.2±6.8 vs. 18.6±4.8 for left pulmonary artery, 22.9±6.7 vs. 18.8±4.7 for right pulmonary artery; primary score:4.0 (4.0, 4.0) vs. 3.5 (3.0, 4.0), all P < 0.05]; and there was no statistically significant difference in the primary or objective evaluation of coronary artery or aortic image quality between the two protocols. In BMI > 23 kg/m2 group, the CT value, CNR and primary scores of coronary artery and aortic images in patients receiving protocol 2 were significantly higher than those receiving protocol 1 [CT value (HU): 369±63 vs. 315±61 for proximal right coronary artery (RCA), 388±63 vs. 323±63 for proximal left coronary artery (LCA), 328±83 vs. 272±51 for ascending aorta, 348±82 vs. 272±49 for aortic arch; CNR: 15.0±4.6 vs. 12.3±4.7 for proximal RCA, 15.7±3.8 vs. 12.8±5.2 for proximal LCA, 13.2±5.3 vs. 10.4±4.1 for ascending aorta, 14.1±5.3 vs. 10.4±3.9 for aortic arch; primary score: 4.0 (3.0, 4.0) vs. 3.0 (3.0, 4.0) for coronary, 4.0 (3.0, 4.0) vs. 3.0 (2.0, 4.0) for aorta; all P < 0.05]; and there was no statistically significant difference in the primary or objective evaluation of pulmonary artery image quality between the two protocols. Conclusions The effective radiation dose of triple-rule-out CT examination of acute chest pain is relatively low. The low-dose iodine contrast agent application program with fixed injection time can meet the needs of clinical diagnosis of triple-rule-out CT examination of acute chest pain patients. For patients with BMI ≤ 23 kg/m2, both protocols 1 and 2 can obtain excellent image quality; in order to avoid the influence of superior vena cava artifacts, protocol 1 is recommended. For patients with BMI > 23 kg/m2, application protocol 2 can obtain stable, excellent image quality that is more suitable for clinical applications.
3.Establishment of goat limbal stem cell strain expressing Venus fluorescent protein and construction of limbal epithelial sheets.
Jiqing YIN ; Wenqiang LIU ; Chao LIU ; Guimin ZHAO ; Yihua ZHANG ; Weishuai LIU ; Jinlian HUA ; Zhongying DOU ; Anmin LEI
Chinese Journal of Biotechnology 2010;26(12):1636-1644
The integrity and transparency of cornea plays a key role in vision. Limbal Stem Cells (LSCs) are precursors of cornea, which are responsible for self-renewal and replenishing corneal epithelium. Though it is successful to cell replacement therapy for impairing ocular surface by Limbal Stem Cell Transplantation (LSCT), the mechanism of renew is unclear after LSCT. To real time follow-up the migration and differentiation of corneal transplanted epithelial cells after transplanting, we transfected venus (a fluorescent protein gene) into goat LSCs, selected with G418 and established a stable transfected cell line, named GLSC-V. These cells showed green fluorescence, and which could maintain for at least 3 months. GLSC-V also were positive for anti-P63 and anti-Integrinbeta1 antibody by immunofluorescent staining. We founded neither GLSC-V nor GLSCs expressed keratin3 (k3) and keratinl2 (k12). However, GLSC-V had higher levels in expression of p63, pcna and venus compared with GLSCs. Further, we cultivated the cells on denude amniotic membrane to construct tissue engineered fluorescent corneal epithelial sheets. Histology and HE staining showed that the constructed fluorescent corneal epithelial sheets consisted of 5-6 layers of epithelium. Only the lowest basal cells of fluorescent corneal epithelial sheets expressed P63 analyzed by immunofluorescence, but not superficial epithelial cells. These results showed that our constructed fluorescent corneal epithelial sheets were similar to the normal corneal epithelium in structure and morphology. This demonstrated that they could be transplanted for patents with corneal impair, also may provide a foundation for the study on the mechanisms of corneal epithelial cell regeneration after LSCT.
Animals
;
Cell Culture Techniques
;
methods
;
Cell Line
;
cytology
;
Epithelium, Corneal
;
cytology
;
metabolism
;
Fluorescent Antibody Technique, Indirect
;
Goats
;
Limbus Corneae
;
cytology
;
Stem Cell Transplantation
;
Stem Cells
;
cytology