1.STUDY ON THE EAP DISTRIBUTION AND PHENOTYPING OF EAP IN HUMAN BLOODSTAINS USING IEF
Chinese Journal of Forensic Medicine 1986;0(02):-
The 340 blood samples from Guangdone area were detected by ultra thin poly-acrylamide gel isoelectric focusing for EAP phenotypes.The phenotypes were20 EAP A,119 EAP BA,201 EAP B.The gene frequencies of EAP were as foll- ows p~(?)0. 2338,p~(?)0. 7662. The 110 bloodstain samples of the cloth kept at roomtemperature for 7 weeks could be phenotyped correctly,The 21 bloodstain samp-les on the porcelain plate kept at room temperature for 9 weeks could be phen-otyped correctly.When the blood volume of bloodstain was equal to or over5?l EAP could be phenotyped.6 out of 20 mouldy bloodstains,the EAP BAphenotype were changed to EAP B.In blind trial,20 bloodstain samples kept atroom temperature for 7 weeds could be phenotped correctly.
2.THE HLA ANTIGENS AND ITS APPLICATION IN FORENSIC MEDICINE
Jingyuan GUO ; Xinyao WU ; Huiling LU
Chinese Journal of Forensic Medicine 1986;0(02):-
Since the HLA system is one of the most complex human genetic polym- orphisms,its application in forensic medicine included disputed paternity and criminal identification,have been fairly recognized. The present paper reported the results of our study about the HLA typing in human blood stain,serum and saliva,it was concluded that:(1).The existed strong anti-complementary activity in human blood stain when the amount of complement used in microlym-phocytotoxicity inhibition test(MLIT) was incresed to 10?l,it was found that the results of HLA-All,-B 5 typing in bloodstains were all correct,and the detectable period was at least 90 days; (2).The soluble HLA-A antigens in human serum could reliable detected with MLIT;(3).The soluble HLA-A antigens were also present in the human siliva.
3.THE PHENOTYPE DISTRIBUTION OF THE RED CELL GLYOXALASE I IN GUANGZHOU AREA AND PHENOTYPING OF GLYOXALASE I IN BLOODSTAINS
Jianjin LI ; Xinyao WU ; Jingyuan GUO
Chinese Journal of Forensic Medicine 1986;0(01):-
The phenotype distribution of human red cell glyoxalase I of a Han population in Guangzhou area was studied using mixed starch/agarose gel electrophoresis. The phenotype frequencies were: GLOI 1-1 2.57%; GLOI 2-1 29.17%; and GLOI 2-2 68.26%. The gene frequencies were: GLOI~1 0.1716; GLOI~2 0,8284. The phenotyping of GLOI was carried out satisfactorily in 35 bloodstains kept in room temperature for 20 days in 7 bloodstains stored in 4℃ for 105 days exposed in sunshine for 8 hours, as well as kept outdoor overnight, and in 10 putrefactive bloodstains kept in room temperature for 9 days.The GLOI were destroyed in 6 of 7 bloodstains washed by runing water for 2 hours.
4.PREPARATION AND PRACTICAL APPLICATION OF MONOCLONAL ANTI-A ANTIDODIES
Yawei ZOU ; Jingyuan GUO ; Yuelong CHEN ;
Chinese Journal of Forensic Medicine 1986;0(02):-
Balb/c mice were immunized by intraperitoneal iniection of group A erythrocytes. Immunized spleen cells were fused with Sp2/0 murine myeloma cells from the solid tumour. After 10~15 days of incubation at 37℃ CO_2, the supernatants were screened for the agglutinabal antibodies. Three hybridoma cell lines secreting high titer and specific monoclonal anti-A antibodies were established.These hybridoma cells have the ability of constant seceting antibodies which belong to the IgM class. The specificity monocloal anti-A sera was the same as the human anti-A sera.
5.Suspension culture of protocorm in Dendrobium candidum
Jingyuan SONG ; Shunxing GUO ; Peigen XIAO ;
Chinese Traditional and Herbal Drugs 1994;0(09):-
Object To study the feasibility of suspension culture of protocorm in Dendrobium candidum Wall ex Lindl and effect of inoculum and medium volume on the growth of protocorm Methods Effect of four basic media MS, 1/2 MS, 67 V, and B 5, inoculum and medium volume on the growth of protocorm were studied by completely random experimental design and orthogonal test design Results The growth of D candidum protocorms in liquid medium was markedly better than that in solid medium (P0 05), B 5 was much better than 1/2 MS (P
6.Determination of the Enantiomer in Safinamide Mesilate by HPLC
Qi ZHANG ; Qianru ZHANG ; Jingyuan LIU ; Wenmin GUO
China Pharmacist 2016;19(3):582-584
Objective: To establish a determination method for the enantiomer in safinamide mesilate. Methods: A Chiralpak ASH (250 mm ×4. 6 mm, 5 μm) column was used with the mobile phase of n-hexane-ethanol-diethylamine (75 ∶ 25 ∶ 0. 1). The flow rate was 1. 0 ml·min-1 . The wavelength was set at 225 nm. The column temperature was 35℃. Results: The resolution of safinamide mesilate and the enantiomer was above 2. 0. The linear range of them was 1. 007-2 517. 500 μg·ml-1 and 0. 909-2273. 200 μg·ml-1 ,respectively(r = 0. 999 0). The average recovery of the enantionmer was 104. 9% with RSD of 2. 3% (n = 9). Conclusion: The method is accurate and rapid, and suitable for the determination of the enantiomer in safinamide mesilate.
7.Construction of the coexpression vector containing key element GLCYP450 involved in Ganoderma triterpene biosynthesis and its reductase gene GLNADPH.
Xu GUO ; Chao SUN ; Jingyuan SONG ; Hongmei LUO ; Shilin CHEN
Acta Pharmaceutica Sinica 2013;48(2):206-10
Cytochrome P450 (CYP450) is a key element in the Ganoderma triterpenoid biosynthetic pathway. The catalytic reaction process for CYP450 requires NADPH / NADH for electron transfer. After searching the genome dataset of Ganoderma lucidum, the unique sequence encoding CYP450 and NADPH were discovered, separately. The open reading frames of GLCYP450 and GLNADPH were cloned separately using RT-PCR strategy from G lucidum. The appropriate restriction enzyme cutting sites were introduced at the 5' and 3' ends of gene sequence. The genes of GLCYP450 and GLNADPH were recombined into the yeast expression vector pESC-URA, leading to the formation of the yeast expression plasmid pESC-GLNADPH-GLCYP450. This study provides a foundation for researching Ganoderma triterpene biosynthesis using the approach of synthetic biology.
8.Simultaneous Determination of 3 Optical Isomers in Carfilzomib by HPLC
Haixia LI ; Na LIU ; Peifeng BAI ; Jingyuan LIU ; Wenmin GUO
China Pharmacist 2016;19(6):1094-1095,1101
Objective:To establish an HPLC method for the determination of optical isomers in carfilzomib .Methods:The sample was separated on a Chiralpak OX-H column.The mobile phase consisted of n-hexane∶isopropanol∶alcohol (89 ∶5 ∶6, v/v/v) with a flow rat of 1.0 ml· min-1 .The detection wavelength was 220 nm.Results:The linear rang of enantiomer , diastereomer Ⅰand di-astereomer Ⅱwas 0.54-2.14 μg· ml -1,0.11-1.80 μg· ml-1 and 0.11-1.81 μg· ml-1(r≥0.998), respectively.The lower limit of quantification was 0.07-0.27 μg· ml-1 .The recoveries of optical isomers were within the range of 99.6%-100.9% with RSD of 1.13%-1.59%(n=9).Conclusion:The method is sensitive, simple, fast, accurate and specific, and suitable for the study of opti-cal isomers in carfilzomib .
9.THE RAPID DETERMINATION OF ABO BLOOD GROUP IN BODY FLUIDS (OR STAINS)BY DOT-ELISA USING ENZYME-LABELLED MONOCLONAL ANTIBODY
Bin ZHOU ; Jingyuan GUO ; Chuanxi WANG ; Jian CHEN ;
Chinese Journal of Forensic Medicine 1987;0(03):-
One step dot-ELISA method for the rapid determination of ABO blood groups in humam body fluids(or stains)was established using enzyme-labelled anti-A,--B and anti--H monoclonal antibody (McAb).The sample was applied on the nitrocellulose membrance as a dot. After washing, the appropriate McAb wasadded on top of the dot, and then followed by adding 3, 3'-diaminobenzidine(DAB). The brown color indi-cated the positive reaction. The ABO blood typing of 521 saliva samples including both secretor and non-se-cretor were carried out. All the results were correct. The advantages of this method are accurate, sensitive,rapid, easy to perform, as well as not time consuming. It is more sensitive than the conventional hemaggluti-naton inhibition test.
10.Intraocular Pressure Sensor Based on a Contact Lens.
Xuhong GUO ; Weihua PET ; Zhaolin YAO ; Yuanfang CHEN ; Xiaohui HU ; Hongda CHEN ; Jingyuan ZHU ; Huijuan WU
Journal of Biomedical Engineering 2016;33(1):18-22
Intraocular pressure detection has a great significance for understanding the status of eye health, prevention and treatment of diseases such as glaucoma. Traditional intraocular pressure detection needs to be held in the hospital. It is not only time-consuming to doctors and patients, but also difficult to achieve 24 hour-continuous detection. Microminiaturization of the intraocular pressure sensor and wearing it as a contact lens, which is convenient, comfortable and noninvasive, can solve this problem because the soft contact lens with an embedded micro fabricated strain gauge allows the measurement of changes in corneal curvature to correlate to variations of intraocular pressure. We fabricated a strain gauge using micro-electron mechanical systems, and integrated with the contact lens made of polydimethylsiloxane (PDMS) using injection molding. The experimental results showed that the sensitivity was 100. 7 µV/µm. When attached to the corneal surface, the average sensitivity of sensor response of intraocular pressure can be 125.8 µV/mm Hg under the ideal condition.
Contact Lenses, Hydrophilic
;
Dimethylpolysiloxanes
;
Glaucoma
;
Humans
;
Intraocular Pressure
;
Tonometry, Ocular
;
instrumentation