1.Cleaning and Disinfection for Digestive Endoscope:A Discussion about Continuing Improvement of Surveillance Management
Jimei YIN ; Bingrong LIU ; Wei LIU
Chinese Journal of Nosocomiology 2006;0(08):-
OBJECTIVE To approach the method for continuing improvement of quality control in cleaning and disinfection.METHODS Looked for the problems in the process of cleaning and disinfection of endoscope,and the reasons wereanalyzed.The specific measures for continuing improvement of quality control in cleaning and disinfection of endoscope were formulated and fulfilled.The examining norms of nursing quality were modified,and the surveillance management of the quality control and the cleaning and disinfection of endoscope were enhanced.RESULTS For continuing improvement of quality control in cleaning and disinfection of endoscope,the total quality of nursing service must be enhanced.CONCLUSIONS For one year practice,we found that continuing improvement of quality control in cleaning and disinfection fo endoscope could enhance total quality of nursing care,and ensure medical treatment safety while decreasing onset of hospital infection.
2.Reasonable Application of Multi-enzyme Abluent in Process of Flexible Endoscope Cleaning and Disinfecting
Ruihua NING ; Jimei YIN ; Hongying YU
Chinese Journal of Nosocomiology 2006;0(12):-
OBJECTIVE To discuss the reasonable application of multi-enzyme abluent in the process of endoscopic cleaning and disinfecting.METHODS The multi-enzyme abluent was reasonably used to clean the endoscope in the pre-cleaning and disinfection process at thebedside,to enable it to achieve the best cleaning effect.RESULTS The reasonable application of multi-enzyme abluent could enhance the effect of endoscope cleaning to ensure the success of endoscopic disinfection.CONCLUSIONS Multi-enzyme abluent can protect the successful endoscopic disinfection and prevent the iatrogenic infection.
3.Uterine artery embolization for treatment of leiomyoma: long term results and effects on outcomes
Xinqiang JI ; Zixiang LI ; Jimei YIN ; Yanji ZHAO ; Yuying DUAN
Journal of Chinese Physician 2009;11(12):1620-1623
Objective To evaluate the effects and safety of uterine artery embolization for uterine leiomyoma. Methods Total of 185 patients with uterine leiomyoma were treated by UAE. They were followed for one to 6 years to observe the changes of leiomyoma size and improvement in clinical symptoms. Ovarian function was evaluated in 44 cases. Results Bilateral embolization of uterine arteries was performed in 185 patients. Follow-up of 1 ~6 years for 292 leiomyoma indicated that one to 9 months after embolization, shrinkage of leiomyoma size was the most significant factor. One year after embolization, leiomyoma sizes decreased a little. Shrinkage of submucous leiomyoma was more significant than that of intratumoral one, and the latter was more significant than subserous one. Shrinkage of leiomyoma with large size ( volume ≥ 150cm~3) was less than that of small one. Menorrhagia, anemia and pressure symptoms were all resolved. There was no significant difference between pre- and post embolization ovarian hormone level. Conclusions The significant reduction in leiomyoma volume and resolution of clinical symptoms confirmed that the treatment validity of symptomatic leiomyomas by UAE. UAE is an effective therapeutic procedure which has no adverse effect on the ovarian function.
4.The safety of endoscopic ligation of gastric and colic full-thickness wall with detachable nylon loops
Jitao SONG ; Jibin YIN ; Bingrong LIU ; Jimei YIN ; Dan LIU ; Yawen YANG ; Hui LI
Chinese Journal of Digestive Endoscopy 2011;28(7):383-385
Objective To evaluate the safety of endoscopic ligation of gastric and colic full-thickness wall with nylon loops.Methods Endoscopic ligation of full gastric and colic wall with detachable nylon loops, assisted by laparotomy, were performed in 4 dogs.Ligation healing was assessed on 3, 7, 10and 17 days after the procedure.Results All animals recovered after the procedure, without any clinical signs of infection or hemorrhage.Postoperative examination did not reveal gastric or colonic perforation, or local abscess.Loop ligature showed ulcer-like lesion.Histopathology revealed muscularis propria disruption, granulation tissue bridging the site of ligation and formation of scar tissue.Regenerative mucosa coyered the surface of the ligature completely 17 days after the operation.Conclusion Endoscopic ligation of gastric and colic full-thickness wall with detachable nylon loops is safe.Its application can be extended to other fields.
5.Can lung ultrasound replace the chest X-ray? A prospective multicenter study
Yangming QU ; Shuyu SI ; Huiqing SUN ; Pingyang CHEN ; Qianshen ZHANG ; Li MA ; Zhaoqing YIN ; Min XIAO ; Jimei WANG ; Xirong GAO ; Ling LIU ; Jinxing FENG ; Yanping ZHU ; Di JIN ; Jing ZHANG ; K. Shoo LEE ; Hui WU
Chinese Pediatric Emergency Medicine 2023;30(11):834-839
Objective:To analyze the accuracy of lung ultrasound and chest X-ray in the diagnosis of neonatal pulmonary disease.Methods:We prospectively collected newborns that needed chest X-ray examination to diagnose pulmonary disease from twelve neonatal intensive care units across the country between June 2019 and April 2020.Each newborn was examined by lung ultrasound within two hours after chest X-ray examination.All chest X-ray and lung ultrasound images were independently read by a radiologist and a sonographer.When there was a disagreement, a panel of two experienced physicians made a final diagnosis based on the clinical history, chest X-ray and lung ultrasound images.Results:A total of 1 100 newborns were enrolled in our study.The diagnostic agreement between chest X-ray and lung ultrasound(Cohen′s kappa coefficient=0.347) was fair.Lung ultrasound(area under the curve=0.778; 95% CI 0.753-0.803) performed significantly better than chest X-ray(area under the curve=0.513; 95% CI 0.483-0.543) in the diagnosis of transient tachypnea of the newborn( P<0.001). The accuracy of lung ultrasound in diagnosing neonatal respiratory distress syndrome, meconium aspiration syndrome, pneumonia and neonatal pulmonary atelectasis was similar to that of chest X-ray. Conclusion:Lung ultrasound, as a low-cost, simple and radiation-free auxiliary examination method, has a diagnostic accuracy close to or even better than that of chest X-ray, which may replace chest X-ray in the diagnosis of some neonatal lung diseases.It should be noted that both chest X-ray and lung ultrasound can only be used as auxiliary means for the diagnosis of lung diseases, and it is necessary to combine imaging with the clinical history and presentation.
6.Chinese neonatal birth weight curve for different gestational age.
Li ZHU ; Rong ZHANG ; Shulian ZHANG ; Wenjing SHI ; Weili YAN ; Xiaoli WANG ; Qin LYU ; Ling LIU ; Qin ZHOU ; Quanfang QIU ; Xiaoying LI ; Haiying HE ; Jimei WANG ; Ruichun LI ; Jiarong LU ; Zhaoqing YIN ; Ping SU ; Xinzhu LIN ; Fang GUO ; Hui ZHANG ; Shujun LI ; Hua XIN ; Yanqing HAN ; Hongyun WANG ; Dongmei CHEN ; Zhankui LI ; Huiqin WANG ; Yinping QIU ; Huayan LIU ; Jie YANG ; Xiaoli YANG ; Mingxia LI ; Wenjing LI ; Shuping HAN ; Bei CAO ; Bin YI ; Yihui ZHANG ; Chao CHEN ; null
Chinese Journal of Pediatrics 2015;53(2):97-103
OBJECTIVESince 1986, the reference of birth weight for gestational age has not been updated. The aim of this study was to set up Chinese neonatal network to investigate the current situation of birth weight in China, especially preterm birth weight, to develop the new reference for birth weight for gestational age and birth weight curve.
METHODA nationwide neonatology network was established in China. This survey was carried out in 63 hospitals of 23 provinces, municipalities and autonomous regions. We continuously collected the information of live births in participating hospitals during the study period of 2011-2014. Data describing birth weight and gestational age were collected prospectively. Newborn's birth weight was measured by electronic scale within 2 hours after birth when baby was undressed. The evaluation of gestational age was based on the combination of mother's last menstrual period, ultrasound in first trimester and gestational age estimation by gestational age scoring system.
STATISTICAL ANALYSISthe growth curve was drawn by using LMSP method, which was conducted in GAMLSS 1.9-4 software package in R software 2.11.1.
RESULTA total of 159 334 newborn infants were enrolled in this study. There were 84 447 male and 74 907 female. The mean birth weight was (3 232 ± 555) g, the mean birth weight of male newborn was (3 271 ± 576) g, the mean weight of female newborn was (3 188 ± 528) g. The test of the variables' distribution suggested that the distribution of gestational age and birth weight did not fit the normal distribution, the optimal distribution for them was BCT distribution. The Q-Q plot test and worm plot test suggested that this curve fitted the distribution optimally. The male and female neonatal birth weight curve was developed using the same method.
CONCLUSIONUsing GAMLSS method to establish nationwide neonatal birth weight curve, and the first time to update the birth weight reference in recent 28 years.
Birth Weight ; China ; Female ; Gestational Age ; Humans ; Infant, Low Birth Weight ; Infant, Newborn ; Male