1.Verification of dose parameters under reference and non-reference conditions for radiotherapy in Liaoning province
Yong CUI ; Baochen LIU ; Zhongxing CHEN ; Junqiao GUO ; Suming LUO ; Zhijian HE ; Jilong YUAN
Chinese Journal of Radiological Medicine and Protection 2014;34(6):456-460
Objective To verify the reliability of dose parameters of radiotherapy under reference and non-reference conditions by using TLD.Methods Dose parameters were verified by using TLDs under reference and non-reference conditions,including the maximum dose in axel of 5 electron beams with energy of 9 MeV and the variations of dose by depth,source-skin distance,exposure field and 45° wedge for 10 photon beams with energy of 6 MV in 5 hospitals.Results The average relative deviation of 6 MV photon beam measured between TLDs and finger ionization chambers were 4.45%,within ± 7% as required by IAEA.The average relative deviation of 9 MeV electron beam measured between TLDs and plane parallel chambers were 2.45%,within ± 5% was required by IAEA.Conclusions Measuring dosimetric parameters by using TLDs under reference and non-reference conditions was reliable and feasible.
2.Rehabilitation of Hemicorporectomy Amputee:A Case Report
Ping YANG ; Xuejun CAO ; Gang TIAN ; Jilong CUI ; Tingjun ZHANG ; Jiehui LI ; Anqing WANG
Chinese Journal of Rehabilitation Theory and Practice 2008;14(5):480-483
Objective To investigate the rehabilitation of pelvis disarticulation amputees.Methods A case report.Results and Conclusion Rehabilitation engineering,assisted with physical therapy,can rebuild hemicorporectomy amputees' standing and walking ability,make them look as normal as possible,help them return to the society.
3.Computer Aided Design and Manufacture of Transfemoral Prosthesis
Qing LAI ; Xuejun CAO ; Jianlong ZHUANG ; Lin WANG ; Zheng TIAN ; Jilong CUI
Chinese Journal of Rehabilitation Theory and Practice 2010;16(3):290-293
ObjectiveTo study a fast and feasible system in clinical application of computer aided socket design and manufacture. MethodsThe biomechanical index were compared of traditional hand-made prosthetic sockets and of computer aided design and manufacture ones based on 3D scanning and reverse engineering. ResultsThe index from 3 cases wearing the computer aided design and manufacture socket prostheses appeared similar or better in static mechanical parameters, walking kinetic parameters and stump-socket interface pressure than they wearing traditional hand-made ones. ConclusionThis computer aided socket design and manufacture system can meet patients' needs in using their prostheses.
4.Comprehensive rehabilitation of child with bilateral hip joint disarticulation and amputation: a case report
Xuejun CAO ; Anqing WANG ; Ning JIN ; Zhuoying QIU ; Shuqing MA ; Yong LUO ; Jiehui LI ; Yawei CHEN ; Jilong CUI
Chinese Journal of Rehabilitation Theory and Practice 2006;12(11):1002-1004
目的探讨截肢后残疾人综合康复策略。方法个案分析。9岁女童,因车祸骨盆以下截肢。各学科专家和社会工作者组成康复团队,进行综合康复。结果4个月后,女童装上假肢,恢复清纯女孩的外观形象,学会使用假肢、轮椅或特制的小滑板代步,日常生活能力(ADL)提高,正常上学,成绩优秀;将来准备向残疾运动员方向发展。结论综合康复可以实现残疾人回归社会。