1.The effect of cementation materials on the fracture resistance of Artglass crown
Journal of Practical Stomatology 2001;0(03):-
Objective: To study the effect of cementation materials on the fracture resistance of metal free premolar Artglass crown. Methods: Thirty extracted human maxillary premolars were regularly prepared for cementation. Artglass crowns were cemented onto the teeth with zinc phosphate cement (ZnP), glass ionomer cement(GIC)or a resinous cement in combination with a dentinal bonding agent. Each of the cementation material was applied in 10 premolars. Artificial crowns were vertically loaded until the Artglass crowns compressed to failure. Significant differences of fracture loads between experimental groups were assessed by paired t test. Results: The fracture load(N) of ZnP, GIC and resinous cement were 1 743.1 ?383.4, 1 682.4?613.7 and 2 226.9?270.1 respectively( P
2.Effects of acid etching time on nanoleakage and microtensile bond strength of the adhesive-dentin bond
Journal of Practical Stomatology 2001;0(01):-
Objective: To observe the effects of acid etching times on nano-leakage and microtensile bond strength(?TBS) of the 4 total-etching adhesives-dentin bond.Methods: Superficial occlusal dentin surfaces of 80 molars were prepared with 600-grit SiC paper under running water.4 adhesives were applied to dentin surfaces under different etching time.The bonded teeth were sectioned occluso-gingivally into 1.0 mm?1.0 mm?4.0 mm serial slabs which were prepared for TEM and ?TBS tests.Results: Under 15 s etching time for 4 adhesives,the highest ?TBS(OB(25.36?4.18) MPa,SB(24.25?3.97) MPa,OS(28.65?4.93) MPa,PB(27.12?4.13) MPa) were achieved,and the amount of nanoleakage was positively correlated with the length of etching time.Conclusion: Etching for a reasonable time demineralizes the dentin surface to a moderate depth,resulting in higher ?TBS and lower nanoleakage.
3.Shear bond strength between brackets and porcelain veneers prepared with different methods
Qilin CHEN ; Hong HE ; Jihua CHEN
Journal of Practical Stomatology 1996;0(02):-
Objective:To test the effects of different preparation methods on the shear bond strength between porcelain veneers and the brackets.Methods:48 metal-porcelain veneers were randomly and evenly divided into two groups. The veneers in group 1 were grinded with stone, while others were intact. The veneers were bonded by acid etching,silicone coupler and acid etching combined with silicone coupler respectively.After bonding and 500 thermo cycle treatment, all veneers were submitted to shear bond strength test and the incidence of porcelain fracture was recorded.Results:The shear bond strength of the grinded samples was higher than that of the intact(P
4.Effects of thickness and opaque resin on the light transmittance of Artglass
Qinglei ZANHG ; Jihua CHEN ; Jianlin ZHAO
Journal of Practical Stomatology 2001;17(3):236-238
Objectives: To evaluate the effect of thickness and opaque resin on the light transmittance of Artglass. Methods: Samples of Artglass prepared in the thickness(mm) of 0.50,0.75,1.00,1.25,1.50,1.75 and 2.00 with or without opaque resin respectively.The light transmittance of the specimens was measured. The color values of the specimens on the CIE L*a*b* color system were determined by a digital chroma meter. Results: The light transmittance of Artglass decreased logarithmically with the increase of the thickness (R2=0.9834 in the group of samples without opaque and R2=0.9390 in those with opaque). The light transmittance of Artglass with opaque resin was lower than that without opaque resin. Conclusion: Thickness and opaque resin have significant effect on the light transmittance of Artglass.
5.Contents change and clinical significance of serum heme oxygenase-1 and unconjugated bilirubin in patient with acute cerebral infarction
Haipeng LI ; Bo XIAO ; Jihua CHEN
Journal of Clinical Neurology 1992;0(01):-
Objective To speculate the contents changes and clinical significance of heme oxygenase-1(HO-1) and unconjugated bilirubin (UCB) in the patients with acute cerebral infarction.Methods HO-1 and UCB in blood serum were measured in these patients with acute cerebral infarction(ACI) and control group at one day, third day,and sixth day after the onset by ELISA and oxidation of vanadate. Results The content of HO-1 and UCB in serum decreased step by step at the first day, third day, and sixth day after the onset. The level of HO-1 displayed a positive correlation with the UCB in serum in the first day after the onset (r=0.645, P
6.Fracture resistances of pulpless teeth restored with two kinds of cast metal post-core or glass-fiber post with a composite core
Wenyun ZHANG ; Changxi SHI ; Jihua CHEN
Journal of Practical Stomatology 2000;0(05):-
Objective: To compare the fracture resistance of pulpless teeth restored with three types of post core.Methods: A total of 21 recently extracted sound upper incisors were randomly distributed into 3 groups. In group A the teeth were restored with prefabricated glass fiber post and composite core; in group B with custom cast titanium alloy post and core; and in group C with Ni Cr alloy dowel core. The size and shape of posts were identical in the 3 groups. All teeth were fully covered with Ni Cr alloy cast crown. Fracture resistance was measured by applying a point force at 130 degrees to the long axis of the teeth. Results: Mean fracture threshold was (276.6?15.1)N in group A, (394.7?29.1)N in group B and (373.4? 53.8 )N in group C. In group B and C, however, fracture always affected the tooth itself,whereas in group A,the core always failed first. Conclusion: Fiber reinforced composite(FRC) post may meet the clinical need, FRC post combined with composite core may prevent tooth root from fracture.
7.Evaluation of 4 dentin adhesives in vivo
Sanjun ZHAO ; Jihua CHEN ; Hui WANG
Journal of Practical Stomatology 2000;0(06):-
Objetives: To evaluate the microtensile bond strengths o f four dentin adhesives (Single Bond, Bond-1, Prime&Bond NT and One-Step) i n vivo.Methods: Before extraction the superficial occlu sal dentin of 19 molars (because of severe periodontitis) in 17 volunteers was exposed by diamond bur of a high-speed hand-piece copious air-water spray under local anesthesia, the crown was bonded with one of the above adhesives a ccording to the manufacturers' instructions. The teeth were then extracted and kept in normal saline for 24 h under 37 ℃,sectioned to obtain two or three bar -shaped specimens, which were then shaped to an hour-glass form. The specimens were stressed until rupture of the bond. The mean bond strength of the adhesive s was measured and compared using student test. Rusults: M ean microtensile bond strength (MPa) of Single Bond,Bond-1,One-Step and Prime & Bond NT to the tooth surface was 26.18?3.67,30.08?3.15,29.91?3.51,29.70?3 .03 respectively (P
8.Emergency surgical treatment of hemoptysis
Changhua DUAN ; Jihua CHEN ; Jiaguang ZHU
Chinese Journal of Primary Medicine and Pharmacy 2008;15(11):1797-1798
Objective To explore discussion medical treatment in massive hemoptysis emergency surgical treatment.Methods Hemorrhage parts,timing of surgery,pneumonectomy scope in 24 cases of massive hemoptysis were analyzed.Results 24 cases of massive hemoptysis emergency surgical treatment were successful,no death and complication rate was 8.3% (2/24).Conclusion For medical treatment ineffective massive hemoptysis determine the location of the bleeding,actively carry out preoperative preparation, choosing the best opportunity emergency resection of lung disease,can be effective in reducing mortality.
9.Mechanical properties of dental base resins prepared with the fast automatic dental base resin hydraulic pressure cooker
Tangmin ZHAO ; Changxi SHI ; Jihua CHEN
Journal of Practical Stomatology 2001;0(01):-
0.05), the FADRHPC could save a great amount of time and worked automatically. Conclusion: The FADRHPC can simplify manipulation processes and make satisfied dentures.
10.The effect of thickness on the fracture resistance of hot pressable ceramic crowns
Hui WANG ; Jihua CHEN ; Changxi SHI
Journal of Practical Stomatology 2001;0(03):-
0.05) than those with that of 1.0 mm (P