1.Advance on pharmacokinetics study of traditional Chinese medicine injections in recent ten years.
Yuan-Rong LIU ; Shu-Yu ZHAN ; Bo-Hong ZHENG ; Meng-Ting FANG ; Yi-Han FENG ; Jie ZHANG ; Ming-Juan LI ; Bao-Yue DING
China Journal of Chinese Materia Medica 2021;46(7):1752-1762
Traditional Chinese medicine(TCM) injections boast a definite efficacy and have been widely used in clinic. However, the problems in medication safety have been attracted increasing attention. Pharmacokinetics is of significance to guiding TCM injection administration regimen design and improving safety and effectiveness in clinical use. In recent years, with the improvement of ideas, technology and methods of TCM studies, the pharmacokinetic studies of TCM injections have been broadly performed, with a notable progress. This paper reviewed the advance in pharmacokinetics studies of TCM injections in recent ten years, which mainly focused on pre-clinical concentration-time course, distribution, metabolism and excretion in vivo based on analysis techniques, pharmacokinetic interactions of constitutes, impact of pathological state, pharmacokinetic interactions between TCM injection and chemical drugs, and clinical pharmacokinetics studies of TCM injections, in the expectation of providing reference for studies on quality control, product development and rational clinical use of TCM injections.
Drugs, Chinese Herbal
;
Injections
;
Medicine, Chinese Traditional
;
Quality Control
2.Profile of irregular antibodies among voluntary blood donors: 2018 to 2020 in Jiaxing
Zhen LUO ; Xiuwen NI ; Jiayan TU ; Jinhui WU ; Jiayi SUN ; Xiaoyuan LI
Chinese Journal of Blood Transfusion 2021;34(11):1245-1247
【Objective】 To study and analyze the profile of irregular antibodies among voluntary blood donors in Jiaxing area. 【Methods】 The ABO and RhD blood groups of all voluntary blood donors from November 2018 to November 2020 were detected by DIAGAST QWALYS 3 automatic blood group analyzer. According to routine serological screening program of irregular antibody, the samples reactive to O blood cell were sent to the reference laboratory for further identification of the antibody specificity, and the specificity and distribution characteristics of irregular antibodies were analyzed statistically. 【Results】 A total of 79 samples presenting irregular antibodies were yielded out of 90 854 blood samples, with a positive rate of 0.087%. More female samples (n=44) than male (n=35) (P<0.05). 29 donors aged 18 to 31, 33 aged 32 to 45, and 17 aged over 45 years old (P<0.05). 73 samples were RhD positive and 6 were RhD negative (P< 0.05). 40 only donated once, and 39 donated more than twice (P>0.05). 【Conclusion】 Female, RhD negative and more than 45 years old blood donors are more likely to present irregular antibodies, regardless of the number of blood donations.
3.Evaluation of CLIA plus NAT for detecting HBsAg single-ELISA-reactive samples of blood donors
Jiayi SUN ; Xiuwen NI ; Zhen LUO ; Chengkuan HUANG ; Jiayan TU ; Xiaoyuan LI ; Wen GAO ; Rui XU
Chinese Journal of Blood Transfusion 2022;35(10):1017-1019
【Objective】 To study the detection performance of HBsAg single-ELISA-reactive samples of blood donors. 【Methods】 Two kinds of ELISA reagents from different manufacturers (named as reagents A and B) were used for HBsAg screening. A total of 276 samples, from January 2017 to May 2021, with HBsAg single-ELISA-reactive results were collected for further nucleic acid detection technology (NAT) and chemiluminescence immunoassay (CLIA) testing, to undergo HBV-DNA and five hepatitis B tests, respectively. The relationship between HBsAg single-ELISA-reactivity, NAT and CLIA was statistically analyzed. 【Results】 Among the 276 HBsAg single-ELISA-reactive samples, 14 were NAT reactive, with the positive rate of 5.07% (14/276). Fisher′s exact test was used to compare the compliance of reagents A and B with NAT reactivity, and the difference was not statistically significant (P<0.05). Among 14 HBsAg+ /NAT+ samples retested by CLIA, 2 were HBsAg reactive(14.29%, 2/14), 13 were anti-HBc reactive (92.86%, 13/14), 9 had the quantitative value of anti-HBs <10 mIU/mL, 5 had the quantitative value of anti-HBs between 10 to 100mIU/ mL. A total of 5 serological patterns were detected, and anti-HBe+ /anti-HBc+ pattern was the dominant. There were 262 cases of HBsAg+ /NAT- samples, but only 1 (0.38%, , 1/262) case was HBsAg reactive by CLIA, 100 were anti-HBc reactive (38.17%, 100/262), 144 (54.96%, 144/262) were anti-HBs reactive, and 1 was HBeAg reactive. A total of 8 serological patterns were detected. 【Conclusion】 Most of HBsAg single-ELISA-reactive results are false, and NAT could effectively reduce the residual risk of transfusion transmitted diseases.
4.Quantitative determination and optimun extraction technique of nine compounds of .
Yihan FENG ; Lei YIN ; Yuanrong LIU ; Lujing CAO ; Ning ZHENG ; Mingjuan LI ; Shuyu ZHAN
Journal of Zhejiang University. Medical sciences 2020;49(3):356-363
OBJECTIVE:
To establish the optimum extraction technique and high performance liquid chromatographic (HPLC) method to simultaneously quantify nine compounds of gallic acid, hydroxy-paeoniflorin, catechin, albiflorin, paeoniflorin, pentagalloylglucose, benzoic acid, benzoylpaeoniflorin and paeonol in .
METHODS:
Linear gradient elution was applied using water containing 0.1%phosphoric acid and acetonitrile as the mobile phase with a flow rate of 0.8 mL/min, column temperature of 30℃ and wavelength of 230 nm. The method of ultrasound extraction was used. Methanol and ethanol were used as extraction solvents, and three factors and three levels of orthogonal experiments was designed using L (3 ) table to investigate the effects of solvent concentration, ratio of liquid to material and extraction time on the total content of nine components of .
RESULTS:
HPLC method was verified to have high specificity, sensitivity and accuracy through methodological validation, and it could be used for simultaneous quantitative analysis of nine components of . The results showed that the optimum extraction technology of nine components of was using 70%ethanol as extraction solvent, ratio of liquid to material was 200 mL/g and ultrasound extraction time was 30 min.
CONCLUSIONS
HPLC method for the simultaneous determination of nine components of is established, and the optimum extraction technology is confirmed.
Chromatography, High Pressure Liquid
;
Drugs, Chinese Herbal
;
Paeonia
5.Colorectal anastomosis using nickel titanium compression anastomosis ring: a prospective study
Liangqing LI ; Juntao SHEN ; Jiaxing WANG
Chinese Journal of Digestive Surgery 2012;11(2):173-176
Objective To investigate the feasibility and safety of colorectal anastomosis using nickel titanium compression anastomosis ring (CAR).MethodsThe clinical data of 83 patients who received colorectal anastomosis at the First Affiliated Hospital of Fujian Medical University from May to December,2010 were prospectively analyzed.All patients were divided into CAR group (41 patients) and stapler group (42 patients) according to the random number table.The operation time,time to postoperative flatus and bowel movement,duration of hospital stay and the incidence of anastomosis-related complications of the 2 groups were observed.The time of extrusion of the rings and anastomotic healing of the CAR group were recorded.All data were analyzed by the t test or chi-square test.ResultsThe mean operation time of the CAR group and the stapler group were ( 122 ± 25) minutes and (128 ±30)minutes,respectively.The incidences of postoperative anastomotic fistula of the CAR group and the stapler group were 5% (2/41) and 7% (3/42),and the anastomotic fistula was cured by operation or conservative treatment.There were no significant differences in the mean operation time,time to postoperative flatus and bowel movement,duration of hospital stay and incidence of anastomotic fistula between the 2 groups (t =1.299,0.756,1.636,0.974,x2 =0.165,P > 0.05 ).The rings were expelled within 9-14 days.The incidences of anastomotic stenosis of the CAR group and stapler group were 0 (0/41) and 2% (1/42),with no significant difference between the 2 groups (x2 =0.988,P > 0.05).The anastomotic stoma was smooth and well bealed in the CAR group,while nail residues and inflammatory polyp (1 patient) were found at the anastomosis stoma in the stapler group.ConclusionNickel titanium CAR is safe and effective in colorectal anastomosis.
6.The effect of the improved maxillary biteplate on the width of mandibular arch
Li LIN ; Jiaxing LIANG ; Quanluan ZHENG
Journal of Practical Stomatology 2000;0(05):-
0.05) respectively. The width of mandibular arch in the treated subjects increased more than that in the controls(P
7.The effects of personality and self-consciousness on the orthodontic compliance of adolescents
Yong CHEN ; Jiaxing LIANG ; Li LIN
Journal of Practical Stomatology 2001;0(01):-
Objective: To study the effects of psychological variables on orthodontic compliance of adolescents.Methods:Prior to orthodontic treatment,60 adolescent patients received two questionnaires for the analysis of their personality(EPQ) and self-consciousness.The compliance of the patients was evaluated at each visit and 6 months after the beginning of treatment by orthodontists.Results:The outgoing personality and the high self-consciousness significantly predicted good orthodontic compliance of the adolescent patients in the treatment(P
8.Role of Toll-like receptor 2/4-nuclear factor-κB signaling pathway in invasion of Mycobacterium tuberculosis to mouse dendritic cells.
Qian XU ; Meng-mei JIN ; Wen-wen ZHENG ; Li ZHU ; Shui-ling XU
Journal of Zhejiang University. Medical sciences 2014;43(2):200-206
OBJECTIVETo investigate the mechanism of Mycobacterium tuberculosis invasion to mouse dendritic cells (DC).
METHODSMycobacterium tuberculosis strain H37Rv was co-cultured with mouse DC2.4 cells.The mRNA expression of Toll-like receptor 2/4(TLR2/4) in DC2.4 cells was detected by fluorescent quantitative real-time PCR and the protein expression of nuclear factor κB(NF-κB) was assessed by Western blotting.The extracellular concentration of tumor necrosis factor α(TNF-α) was measured by ELISA methods during Mycobacterium Tuberculosis invasion.Indirect immunofluorescent staining and flow cytometry assay were used to detect the expression of CD80 and CD86 on DC2.4 cells before and after invasion.
RESULTSThe invasion of Mycobacterium tuberculosis in DC2.4 cells was observed after 2 h of co-incubation.The rates of invasion were (37.9±5.6)%,(51.2±7.6)%,(57.2±8.9)% and(63.9±6.8)% at 6,8,10 and 12 h after co-incubation,respectively.The mRNA expression level of TLR2 /4 was significantly increased at 6 h but decreased at 10 h after co-incubation.The expressions of NF-κB p65 and TNF-α were higher in DC2.4 cells after being invaded by 6,8,and 10 h and then gradually decreased.CD80 and CD86 expression were increased on DC2.4 at 6 h after co-incubation.
CONCLUSIONInvasion of Mycobacterium tuberculosis strain H37Rv to DC might enhance its antigen-presenting function through activation of TLR2/4-NF-kB signaling pathway.
Animals ; B7-1 Antigen ; metabolism ; B7-2 Antigen ; metabolism ; Cells, Cultured ; Dendritic Cells ; immunology ; metabolism ; Mice ; Mycobacterium tuberculosis ; NF-kappa B ; metabolism ; Signal Transduction ; Toll-Like Receptor 2 ; metabolism ; Toll-Like Receptor 4 ; metabolism ; Tumor Necrosis Factor-alpha ; metabolism
9.Establishment of Automation System for Detection of Alcohol in Blood.
Lin Lin TIAN ; Lei SHEN ; Jin Feng XUE ; Ming Ming LIU ; Li Jun LIANG
Journal of Forensic Medicine 2017;33(1):25-27
OBJECTIVES:
To establish an automation system for detection of alcohol content in blood.
METHODS:
The determination was performed by automated workstation of extraction-headspace gas chromatography (HS-GC). The blood collection with negative pressure, sealing time of headspace bottle and sample needle were checked and optimized in the abstraction of automation system. The automatic sampling was compared with the manual sampling.
RESULTS:
The quantitative data obtained by the automated workstation of extraction-HS-GC for alcohol was stable. The relative differences of two parallel samples were less than 5%. The automated extraction was superior to the manual extraction. A good linear relationship was obtained at the alcohol concentration range of 0.1-3.0 mg/mL (r≥0.999) with good repeatability.
CONCLUSIONS
The method is simple and quick, with more standard experiment process and accurate experimental data. It eliminates the error from the experimenter and has good repeatability, which can be applied to the qualitative and quantitative detections of alcohol in blood.
Automation
;
Chromatography, Gas/methods*
;
Ethanol/blood*
;
Gas Chromatography-Mass Spectrometry/methods*
10.Effectiveness of rhomboid intercostal and sub-serratus plane block in improving early recovery quality after thoracoscopic radical surgery for lung cancer
Qian HAO ; Hongyu DAI ; Chunyan LI ; Hongmei ZHOU ; Zhipeng ZHU
China Modern Doctor 2024;62(8):25-29
Objective Verify the improvement effect of rhomboid intercostal and sub-serratus plane block on the quality of early postoperative recovery in patients undergoing thoracoscopic radical resection of lung cancer;Comparison of the differences in the effect of regional block at different timing on improving the quality of early postoperative recovery.Methods A total of 75 patients,aged 18 to 75 years,with ASA gradeⅠ-Ⅱ,who were scheduled to undergo thoracoscopic radical resection of lung cancer from January 2022 to January 2023 were selected.Randomly divided into three groups:blank control group(Group C),preoperative block group(PR group),and postoperative block group(PO group).The PR group and the PO group received ultrasound guided rhomboid intercostal and sub-serratus plane block in the preoperative anesthesia preparation room and postoperative anesthesia recovery room,respectively,with a dosage of 0.375%ropivacaine 30ml.Evaluate the postoperative recovery quality of patients at 24 and 48 hours using the postoperative recovery quality rating scale(QoR-40)scoring scale.Record numeric rating scale(NRS)pain scores in resting and active states at 0.5h,1h,2h,4h,8h,12h,24h,and 48h after surgery.Record the consumption of opioid drugs during and after surgery,the effective number of postoperative patient-controlled intravenous analgesia(PCIA)compressions,and the incidence of nausea and vomiting.Results Compared with Group C,the consumption of opioids during surgery in the PR group was significantly reduced.The QoR-40 score at 24 hours after surgery was significantly higher in the PR and PO groups.Significant reduction in NRS scores between 1-8 hours of rest and 1-12 hours of activity after surgery,and the effective times of PCIA compressions and opioid consumption were significantly reduced(P<0.05).Compared with the PR group,the PO group consumed more opioids during surgery and had a higher NRS score at 0.5 hours after surgery(P<0.05).There was no significant difference in postoperative QoR-40 scores,PCIA effective compressions,and opioid consumption;There was no statistically significant difference in the incidence of postoperative nausea and vomiting among the three groups.Conclusion Rhomboid intercostal and sub-serratus plane block can improve the early recovery quality of patients undergoing thoracoscopic radical resection of lung cancer,reduce the postoperative pain level of patients,and reduce the amount of opioids used in perioperative period,and its effectiveness has nothing to do with the blocking time.