1.The working principle of the dialysate heating and mixture ratio system and the effect of dialysate temperature on renal fibrosis in dialysis patients with end-stage renal
China Medical Equipment 2016;13(3):18-21
Objective:To explore the significance of blood dialysis device for real-time monitoring of dialysate temperature.Methods: Nikkiso DBB-27-type hemodialysis device was selected as a subject for discussion, analyzed and discussed the working principle, main structure and functional characteristics of the mixture ratio of dialysate and temperature monitor and combined with one case of temperature troubleshooting case.Results: Temperature monitoring was essential to ensure the stable running of dialysate mixture ratio and the temperature of the dialysate.Conclusion: The dialysate temperature has an important effect on renal fibrosis in end-stage hemodialysis patients, it is necessary to monitor the dialysate temperature and mixture ratio. Dialysis device heating degas proportioning system through surveillance system linked to the dialysis unit normal, stable operation, provide safe and reliable dialysis treatment for patients.
2.The explore of the protective effect of the far-infrared radiation therapy for hemodialysis patients arteriovenous fistula function
Yanping GU ; Lei JIN ; Jiawei YAN
China Medical Equipment 2015;(8):47-50
Objective:By analyzing the principle and mechanism of far-infrared radiation therapy, explore the far infrared radiation therapy for arteriovenous fistula function protection significance. Methods: Summarized and analyzed in hemodialysis patients arteriovenous fistula dysfunction causes and hazards, combined with clinical results, analyzed the intervention and protective effect of far-infrared radiation therapy for arteriovenous fistula.Results: Long-term treatment of far-infrared radiation play a very effective role in the intervention and protection for arteriovenous fistula function maintenance.Conclusion: By analyzing the principle and mechanism of far infrared radiation therapy, summed arteriovenous fistula dysfunction reasons. Clarified the far-infrared radiation therapy has a positive clinical significance in hemodialysis patients arteriovenous fistula function of protection.
3.Effects of growth stages and pH value on the expression of autolytic enzyme atIS gene of Streptococcus gordonii.
Min LIU ; Jiawei YAN ; Yaling LIU ; Yuqing HAO
West China Journal of Stomatology 2015;33(1):80-83
OBJECTIVEThis study aimed to detect the difference in the expression levels of autolysin atIS gene of Streptococcus gordonii (S. gordonii) at different growth stages and pH values, as well as to analyze the factors regulating atlS gene expression in S. gordonii.
METHODSS. gordonii wild strains (ATCC 35105) were collected at different growth stages (early exponential phase, mid-exponential phase, late exponential stage, and platform stage) and pH values (pH 7 and pH 5.5), and total RNA was extracted by using a conventional method. Fluorescence quantitative polymerase chain reaction (FQ-PCR) was used to measure the relative mRNA expression of atlS gene, with bacterial 16S rRNA as internal reference, for a comparison of the mRNA levels of atlS gene expression in S.gordonii at different growth stages and pH values.
RESULTSFQ-PCR results showed that atlS gene expression increased with gradually increasing growth stage under neutral conditions and was higher than that under acidic conditions (P < 0.05).
CONCLUSIONThe atlS gene expression in S. gordonii is influenced by growth stage and pH value factors.
Bacterial Proteins ; Gene Expression ; Humans ; Hydrogen-Ion Concentration ; RNA, Ribosomal, 16S ; Streptococcus gordonii
4.Evaluation of right ventricular diastolic function in patients with essential hypertension by quantitative tissue velocity imaging
Jiawei TIAN ; Yumei YAN ; Litao SUN ; Ying LIU
Chinese Journal of Ultrasonography 2008;17(10):840-842
Objective To analyze right ventrieular diastolic dysfunction in essential hypertension by quantitative tissue velocity imaging(QTVI). Methods Twenty normotensives and forty-five hypertensives underwent standard Doppler echocardiography and QTVI of right ventricular lateral tricuspid annulus. By QTVI,diastolic measurements were obtained. According to WHO standard, the patients with hypertension were classified into three groups, grade Ⅰ (group Ⅰ) 15 cases, grade Ⅱ(group Ⅱ) 15 cases, grade Ⅲ (group Ⅲ) 15 cases. Results Pulsed Doppler eehocardiography showed impaired Doppler diastolic indexes in hypertensives, without changes among the eases groups. In all hypertension groups, QTVI showed reduction of right ventricular Ea, increase of Aa and Ea/Aa<1 comparison with controls. IVRT of Ⅱ, Ⅲgroups was longer than normal. Conclusions Right ventricular diastolic function with essential hypertension decreased according to the degree of staging. QTVI has a greater predictive value than conventional imaging, and is useful for evaluating right ventricular function in patients with essential hypertension.
5.The relationship between posttraumatic stress disorder and ethical decision- making in nurses suf-fered workplace violence
Xiaofang RUAN ; Yan HU ; Yayun SU ; Jiawei WU
Chinese Journal of Practical Nursing 2016;32(12):893-896
Objective To investigate the posttraumatic stress disorder(PTSD) and ethical decision-making in nurses suffered workplace violence, and analyze the relmionship between them. Methods Totally 340 nurses suffered workplace violence were questionnaired by the PTSD Scale and the Ethical Decision- making Scale. Results The incidence rate of PTSD was 17.06%(58/340), the total score of PTSD was (38.77± 13.57).The scores of ideal ethical practice, actual ethical practice and ethical decision- making in the PTSD group were 121.36±8.33, 105.56±7.76, 226.92±15.52, and were significantly lower than that in the non-PTSD group (140.60±9.01, 117.65±8.41, 258.27±16.73) (t=-14.996, -10.015, -13.153, P < 0.01). The score of PTSD was negtively correlated with the scores of ideal ethical practice, actual ethical practice and ethical decision- making (r=-0.415, -0.431,-0.420, P < 0.05). Conclusions The PTSD probably occurred after workplace violence, nursing administrators should pay close attention to the PTSD and therefore improve nurses′ethical decision-making.
6.Application of echocardiography in transcatheter closure of ventricular septal defect with Amplatzer occluder
Jiawei TIAN ; Yan QIN ; Bo YU ; Al ET
Chinese Journal of Ultrasonography 1993;0(01):-
Objective To probe the value of using echocardiography in transcatheter closure of ventricular septal defect (VSD).Methods Under transthoracic echocardiography and digital subtraction angiocardiography monitoring and guidance in the operation,the Amplatzer excentric umbrella occluder was used to occlude the perimembranous defects in 15 cases of patients.Results All of the patients were treated successfully,though mitral regurgitations or residual shunts occurred in 6 cases,and disappeared at once after the position and direction of occluder were regulated in 3 and these complications disappeared gradually one month postoperation in other 3 patients.The umbrella separated from VSD in 1 and occluded successfully when manipulated once again.Complete heart block occurred in 2 and disappeared after 3 days.The positions of umbrella were normal and stable and no other complications were discovered when these patients were followed about 10 months the longest.Conclusions Echocardiography plays an important role in transcatheter closure of VSD with the Amplatzer occluder before,during and after operation and in the period of follow up.
7.Effect of Arsenic Trioxide on Human Hepatoma Cell Proliferation and Its uPAR Expression
Yan ZHOU ; Jiawei YU ; Hongxia WU ; Zhijian YU
China Pharmacy 2007;0(28):-
OBJECTIVE:To investigate the effect of arsenic trioxide(As2O3)on human hepatoma cells SMMC-7721 viability and the expression of urokinase plasminogen activator receptor(uPAR).METHODS:SMMC-7721 cells were cultured and treated with As2O3 at different concentrations for different time with untreated SMMC-7721 cells(without As2O3 treatment)served as control.The proliferation rate of the SMMC-7721 cells was measured by MTT assay;the change of cell cycle was detected by flow cytometry analysis;the effect of As2O3 on uPAR mRNA levels was analyzed by real-time fluorescent quantitative polymerase chain reaction.RESULTS:As2O3 had significant inhibitory effect on SMMC-7721 proliferation in time-dependent and concentration-dependent manner.As compared with control group,As2O3 significantly decreased the proportion of cells in G0/G1 phase but increased the cell proportion in G2/M phase,and it markedly down-regulated the level of uPAR mRNA expression(P
8.Surgical treatment of failure interventional cases in congenial heart disease
Xuan LI ; Wei GAO ; Jiawei QIU ; Jun YAN ; Rui JIANG ; Peng YAN ; Dianyuan LI
Chinese Journal of Thoracic and Cardiovascular Surgery 2015;31(7):391-393
Objective To summarize the cases of surgical treatment of patients with patent ductus arteriosus (PDA),atrial septal defect(ASD),or ventricular septal defect(VSD) after failure of congenital cardiac catheterization(CCC).Methods From January 2000 to December 2013 in our hospital 26 patients were retrospectively studied,follow-up results recorded for each patient by telephone and outpatient follow-up review.Results There were no deaths.The average age of the patients was (18.8 ± 17.9) (3.0-67.0) years old.The median time of the intervals between interventions and surgeries were 14 days(2 hours to 5 years),the median length of hospital stay were 10 days(7-21 days),median cardiopulmonary bypass time was 67minutes (0-206 minutes),the median blocking time 40 minutes (0-90 minutes),the median time of mechanical ventilation 8.5 hours (2.0-88.0 hours),median ICU stay one day (1-6 days).The average follow-up were (93.0 ± 49.3) months (7.0-182.4 months).Surgical results were satisfactory.Conclusion Interventional treatment of congenital heart disease (CHD) is safe after all,but should strictly the indications controlled,the operations completed by skilled doctors.If there are complex complications,surgical intervention should be concerned,and the results are satisfactory.Patients after CCC should be followed up regularly.
9.Evaluation of pulmonary arterial hypertension with simple congenital heart disease using tissue Doppler imaging
Pei DU ; Guoqing DU ; Hairu LI ; Shuang CHEN ; Yan WU ; Jiawei TIAN
Chinese Journal of Ultrasonography 2014;23(8):645-650
Objective To evaluate the value of tissue Doppler imaging (TDI) in diagnosing pulmonary arterial hypertension(PAH) with common simple congenital heart disease(CHD).Methods 104 patients of CHD approved by operation or intervention were retrospectively analyzed.Both TDI and right cardiac catheterization were performed in all patients,whose were divided into PAH and non-PAH groups according to mean pulmonary arterial pressure (mPAP) on diagnostic right cardiac catheterization:60 PAH patients[mPAP ≥25 mmHg(1 mmHg =0.133 kPa) and pulmonary arterial capillary wedge pressure ≤15 mmHg],44 non-PAH patients (mPAP <25 mmHg).The PAH group was divided into mild (25 mmHg≤ mPAP≤35 mmHg),moderate (36 mmHg≤mPAP≤50 mmHg) and severe (mPAP>50 mmHg) subgroups.The tricuspid annular systolic peak velocity (TS'),early diastolic peak velocity (TE'),late diastolic peak velocity (TA') were measured by TDI and TE'/TA' and Tei index were calculated.The correlation between TDI parameters and the cardiac catheterization findings (sPAP,mPAP and dPAP) were assessed.Results ①TS' and TE' in PAH group were significantly lower than those in non-PAH(P < 0.05),but Tei in PAH group were significantly higher than that in non-PAH (P <0.001),however,there were no significant difference in TA' and TE'/TA' between two groups (P > 0.05).②Tei correlated positively with pulmonary arterial pressure (P <0.001),TS' was found to be negatively correlated with pulmonary arterial pressure(P <0.05),but no correlation between TE',TA',TE'/TA' and pulmonary arterial pressure(P >0.05).③ROC analysis showed the area under curves for Tei index and TS' diagnosis for PAH was 0.893 and 0.699,respectively.At the cutoff of Tei>0.49 and TS'<16 cm/s for indicating PAH,the sensitivity were 86.67 % and 80.00%,respectively and the specificity were 79.55 % and 45.45 %,respectively.④Tei in the moderate and severe PAH were significantly higher than that in mild PAH (P < 0.05),TS' and TE' in severe PAH were significantly lower than those in mild and moderate PAH (P < 0.05),At the cutoff of Tei>0.55 for indicating moderate or severe PAH,the sensitivity and specificity were 95.24% and 72.22%.Conclusions Tei index and TS' have high application value in assessing PAH and classification of PAH.Tei>0.49 indicates PAH,while Tei>0.55 suggests moderate or severe PAH.
10.Automatic evaluation of left ventricular systolic function in rats with myocardial infarction by myocardial contrast echocardiography based on mathematical morphology algorithm
Shuang CHEN ; Guoqing DU ; Jingyi XUE ; Pei DU ; Yan WU ; Hairu LI ; Jiawei TIAN
Chinese Journal of Ultrasonography 2014;23(10):897-901
Objective To evaluate the feasibility and value of quantitatively assessing left ventricular systolic function in rats with myocardial infarction (MI) by myocardial contrast echocardiography (MCE) based on mathematical morphology algorithm.Methods SD rats model of MI were mede,then MCE were performed before MI and at 1,3 weeks after MI.In vitro study:based on the principle of binary morphology,segmentation of endocardium was acquired using dilation,erosion,closed operations and connected domain object tag-based.The automatic segmentation of endocardial contour was compared with the manual segmentation boundary.In vivo study:the left ventricular area was calculated using the software,and the area variation fraction (AVF),a new index of left ventricular systolic function,were acquired.The correlation between AVF and left ventricular ejection fraction (LVEF) was analyzed.The value of AVF for diagnosis for left ventricular dysfunction was evaluated by ROC curve.Results ① The cross-correlation coefficient (CCC) and percent error (PE) between automatic contours and manual boundary were more than 0.90 and less than 9%,respectively.② AVF correlated positively with LVEF (r =0.934,P < 0.001).③ ROC analyses showed the area under curves for AVF diagnosing left ventricular dysfunction was 0.834.The best cutoff value was 27.5 % for diagnosing left ventricular dysfunction with the sensitivity of 85 % and specificity of 60 %.Conclusions Left ventricular endocardium can be identificated automatically and rapidly by MCE based on mathematical morphology algorithm.AVF can assessed quantitatively left ventricular systolic function in rats with myocardial infarction.