1.Study on Fuzzy Mathematical Algorithm Used in Traditional Chinese Medicine Pulse Diagnosis
Wei JIN ; Yan ZHANG ; Jiasheng NI
Chinese Journal of Information on Traditional Chinese Medicine 2016;23(6):1-4
Targeting characteristic information processing of TCM pulse diagnosis, this article studied the application of fuzzy mathematics in objectifying pulse diagnosis. By analyzing limitations of traditional analytic methods, this article offered the scientific evidence of using mathematical algorithm in pulse diagnosis. At the same time, combined with actual clinical data, it also verified the correctness of introduction mathematical algorithm in TCM pulse diagnosis.
2.Comparison of percutaneous vertebroplasty and kyphoplasty in the treatment of osteoporotic vertebral compression fractures
Wei CHEN ; Caifang NI ; Xuan WANG ; Jiasheng HUANG ; Jianbang ZHU ; Jin ZHAO ; Suying CHEN ; Ying ZHONG
Chinese Journal of Radiology 2011;45(9):858-862
ObjectiveTo investigate and compare the efficacy, safety, and cost effectiveness in the treatment of painful osteoporotic vertebral compression fractures ( OVCFs ) with percutaneous vertebroplasty (PVP) and kyphoplasty(PKP). MethodsSeventy-two patients (96 vertebrae) with painful OVCFs were treated by PVP (n =34) or PKP (n =38) under radiological monitoring. After bone biopsy needle into the compressed vertebra, bone cement (polymethylmethacrylate) was injected in PVP group, and that was inserted followed by the inflation of vertebra to create cavities in PKP group. The fluoroscopy time, total amount of bone cement injected, and cost were recollected respectively. The score of visual analogue scale point( VAS, 10-point scale)was determined at before the procedures, and 24 hours, one week, and one month after the procedures.Pain relief and complications were observed.The Cobb angle and vertebral heights of the anterior, middle, and posterior border were measured pre-and post-operative. ResultsThe two procedures were technically successful in all patients. The follow-up ranged from 1. 0 to 34. 0 months [mean time, (8. 9 ±3.2) months]. The Mean fluoroscopy time of treating per vertebra in PVP group was ( 11. 1 ± 10. 6 ) min, which was significant shorter than that ( 23.5 ± 13. 0) min in PKP group( P <0. 05 ).The mean total cost per patient was (5127. 2 ± 502.3 ) yuan in PVP group, which were strikingly lower than that(32 301.4 ±3204. 6) yuan in PKP group (P <0. 05).(3)There was no significant difference( P >0. 05 ) in average cement volumes in PVP group [ (4. 9 ± 1.1 ) ml]and PKP group [ (5.4 ± 1.7 ) ml]. Pain relief of was observed in 94. 1% (32/34) of PVP group and in 92. 1% (35/38) of PKP group. The score of VAS at pre-operation was (8. 3 ±0. 4 vs 7.9 ±0. 8) ,and at post-operative 24 h (2. 9 ±0. 9 vs 2. 8 ± 1. 2),1 week (2.6 ± 0. 9 vs 2.6 ± 1. 1 ), and 1 month (2.6 ± 0. 9 vs 2. 5 ± 1.3 ) were no difference at PKP and PVP group(P <0.05). There was significant difference between pre- and post-operative time point in each group. The Cobb angle, anterior and middle height of vertebra was corrected in both PVP and PKP group. In PVP group, the preoperative Cobb angle, anterior and middle height of vertebra was (24. 2 ± 3.8 )°,( 19. 1 ± 1.4) mm, (25. 2 ± 1.0) mm, which was significant different ( P < 0. 05 ) from that of ( 19.4 ±3.9)°, (21.0 ± 1.5) mm, (27.0 ± 1.2) mm at pre-operation.In PKP group,there was significant difference (P < 0. 05 ) in the preoperative Cobb angle, anterior and middle height of vertebra [(25. 1 ±5.0)°vs(10.7 ±2.8)°, (19.5 ± 1.5) mm vs (24.3 ± 1.9) mm, (25.4 ± 1.1) mm vs (29.7 ±1.3) mm, respectively]. As to the above index, the overall correcting effect in PKP was much better than that in PVP( P <0. 05 ). Cement leakage occurred in 9 cases in PVP group and 3 cases in PKP group ( P <0. 05 ) but no symptoms. There were no major complications during operation in the two groups. Conclusion PVP and PKP are effective and safe in the treatment of painful OVCFs but PVP is more cost effective than PKP.
3.Clinical research of fast track program in anorectal surgery perioperative period
Yujiang LI ; Zhenfei SUN ; Ni LU ; Guanyu QIAO ; Xiaolei QU ; Guixin LI ; Xiaoli ZHANG ; Jiasheng SUN
Chinese Journal of Postgraduates of Medicine 2011;34(8):14-16
Objective To study the safety and efficacy of fast track program in anorectal surgery perioperative period. Methods One hundred and sixty-nine cases of rectal cancer were divided into the study group of 86 patients with fast track program, and the control group of 83 patients with traditional programs by random digits table. Both groups were compared from the time out of bed, the first intestinal discharge time,intravenous fluids stopping time,length of hospital stay,total cost of treatment and the incidence of postoperative complications. Results The study group compared with the control group: the first intestinal discharge time [(33.6 ± 12.9) h vs. (81.7 ± 20.1) h], intravenous fluids stopping time [(4.5 ±1.3) d vs.(7.4 ± 1.6) d],and length of hospital stay [(5.6 ± 1.2) d vs.(8.9 ±2.7) d],the total cost of treatment [(15 000 ± 3000) yuan vs. (16 000 ± 4000) yuan], the differences were statistically significant (P < 0.01 or < 0.05),and had less incidence of postoperative complications in study group than that in control group [5.8% (5/86) vs. 16.9% (14/83)], the difference was statistically significant (P < 0.05).Conclusions Fast track program in anorectal surgery perioperative period is safe and effective, beneficial,conducive to rehabilitation of patients.
4.No.12 lymphadenectomy for distal gastric cancer patients undergoing D2 radical gastrectomy
Zhongkai NI ; Kai YAO ; Chuanbing CHENG ; Shuren LI ; Daoming WANG ; Qi KONG ; Jiasheng ZHU
Chinese Journal of General Surgery 2014;29(6):416-420
Objective To study the significance of No12 lymphadenectomy in patients of advanced distal gastric cancer undergoing D2 distal or total gastrectomy.Methods Clinical and pathological data of 193 distal gastric cancer cases undergoing D2 gastrectomy and No12 lymphadenectomy during Jan 2012 and Jan 2013 were analyzed retrospectively.Results In Borrmann Ⅲ,Ⅳ No.12a LN metastasis was significantly higher than that in Borrmann Ⅰ,Ⅱ (x2 =4.841,P =0.028).In cases of multiple cancer 12a LN metastasis was significantly higher than that in gastric angle,gastric antrum (11.1% 、9.7% 、30.4%).High-differentiated cancer was lower in LN metastasis than that of low differentiated both in No.12a group (x2 =4.292,P =0.038),and in No.12b group (x2 =4.079,P =0.043).In cases with serosal invasion LN metastasis was higher than that without infiltration both in No.12a group (x2 =8.107,P =0.004),and in 12b group (x2 =3.836,P =0.050).In cases of N 0 ~ 1 the LN metastasis was lower than that in N 2 ~ 3 in 12a group (x2 =10.960,P=0.001),12b group (x2 =4.989,P =0.026),and in 12p group (x2 =4.433,P =0.035 respectively).In cases of tumor diameter <3 cm,3 ~5 cm and >5 cm,the 12a lymph node metastasis rate was 4.2%,10.0%,and 29.2%,respectively.Tumor size > 5 cm has higher metastasis rate in No.12a group (x2 =6.464,P =0.011).Conclusions No.12 lymphadenectomy should be included routinely in D2 gastrectomy in patients of distal gastric carcinoma.
5.Feasibility study of guiding catheter passing through spasmodic vess els during percutaneous coronary intervention via radial artery access by the aid of PCI guiding wire and balloon
Zhuhua NI ; Lefeng WANG ; Xinchun YANG ; Hongshi WANG ; Li XU ; Weiming LI ; Kun XIA ; Yu LIU ; Jifang HE ; Yonghui CHI ; Dapeng ZHANG ; Junping DENG ; Yimin WANG ; Guangjun LIU ; Xiaoliang ZHANG ; Jianhong ZHAO ; Jiqiang ZHANG ; Jiasheng LIU ; Shuying QI
Chinese Journal of Interventional Cardiology 2016;24(6):320-325
Objective To explore the safety and feasibility of guiding catheter passing through spasmodic vessels in patients undergoing percutaneous coronary intervention (PCI) via radial artery access by the aid of PCI guiding wire and balloon .Methods The clinical data of 33 coronary artery disease (CAD) patients undergoing PCI via radial artery access with radial artery or (and) brachial artery spasm ( group A ) were retrospectively analyzed .Among all these patients , guiding catheters were delivered through the spasmodic vessels successfully by the aid of PCI guiding wires and balloons .The clinical data of other 38 CAD patients having PCI during the same period performed by other operators via radial artery or ( and ) brachial artery approach and experienced vessel spasm were anlysed as the control ( group B ) .All patients in group B received conventional anti-spasm management during PCI .All vessel spasm was identified by angiography.For patients in group A , a diameter of 0.014 inch guiding wire was chosen to pass through the spasmodic vessel segment carefully and gently .The diameter of balloon should be chosen according to the diameter of guiding catheter .A balloon diameter of 2.0 mm and 2.5 mm was corresponded to 6F and 7F guiding catheter respectively .The balloon was advanced to the tip of guiding catheter , keeping a half in catheter and a half in vessel followed by inflating the balloon with a pressure of 8 atm.The balloon was kept inflated the guiding catheter was pushed in vitro carefully and slowly until the catheter passed through the spasmodic vessel segment .Then the balloon was deflated and pulled out together with PCI guiding wire . Exchanged a diameter of 0.035 inch wire and completed the positioning of guiding catheter .After finishing the PCI, radial or ( and) brachial angiography was performed again to observe if spasm disappeared and to determine if there any contrast medium exudation .For patients in group B , routine approach was applied including administration of nitroglycerine , diltiazem or nitroprusside etc . to relieve vessel spasm. Results The location of vessel spasm was similar in group A and group B ( P=0.150 ) , and the incidence rate of spasm in brachial artery was higher than that in radial artery in both groups .The chance of guiding catheter crossing the spasmodic vessel segment was significantly higher in group A than in group B ( 100%vs.39.5%, P=0.00).In patients whose guiding catheter could pass through the spasmodic vessel segment successfully , time spent in group A was shorter than in group B ( P=0.000 ) .The patient number which time spent was less than five minutes , five to 15 minutes and more than 15 minutes was 30 and 2 ( 90.1%vs.13.3%) , 3 and 7 ( 9.9% vs.46.7%) and 0 and 6 ( 0% vs.40.0%) in group A and in group B respectively.The incidence of forearm hematoma was lower in group A than in group B without statistical difference [6.1%(2/33) vs.18.4%(7/38), P =0.113].Conclusions It is safe and feasible for passing guiding catheter through spasmodic vessels during PCI via radial artery access by the aid of PCI guiding wire and balloon .
6.Management System of Implantable Medical Device in Accordance with JCI Standard Based on HRP System.
Jiasheng NI ; Qilin TAO ; Hongmin ZHU ; Jing GENG
Chinese Journal of Medical Instrumentation 2019;43(4):310-312
JCI standard is the most professional and authoritative certification standard of medical quality and safety system in the world. HRP information system is a systematic hospital resource management platform which integrates the existing hospital information resources and establishes a set of unified, efficient, interconnected and information sharing operation and management of the hospital. In order to meet the requirements of closed-loop management of implantable medical devices in the JCI standard, our hospital has established a set of standards which based on the HRP system platform, including access permission, purchase application, entering and leaving the warehouse, bookkeeping charge, cost accounting and postoperative traceability of implanted medical device management system. HRP system improves the management level of implantable medical devices, and realizes the closed-loop management of the whole process of implantable medical devices.
Hospitals
;
Humans
;
Information Dissemination
;
methods
;
Management Information Systems
;
standards
;
Prostheses and Implants