1.Continuous Detection Method for Ractopamine with Surface Plasmon Resonance Biosensor
Hui LI ; Haoyuan CAI ; Xing CHEN ; Jianhai SUN ; Lulu ZHANG ; Dafu CUI
Chinese Journal of Analytical Chemistry 2010;38(3):381-384
The interaction between the anti-Ractopamine (Rac) monoclonal antibody and the Rac derivation immobilized on the sensor chip surface was studied with surface plasmon resonance (SPR) biosensor. A continuous detection method based on the linear response during the association phase was developed. The sensor chip surface was regenerated after several tests performed continuously, thus the detection step was simplified and the life span of the chip was prospected to be prolonged. The detection was performed as an inhibitive immunoassay. The mixture of anti-Rac monoclonal antibody and the sample flowed over the surface with Rac derivation was immobilized. The relative response was in inversely proportion to the concentration of Rac. The detection limit was less than 4 μg/L with a detection time of 15 min.
2.Micro-Electro-Mechanical Systems-based Gas Chromatography Columns with High Performance
Jianhai SUN ; Dafu CUI ; Haiyuan CAI ; Hui LI ; Zhanwu NING ; Xing CHEN ; Lulu ZHANG ; Yanfei REN
Chinese Journal of Analytical Chemistry 2010;38(2):293-295
The fabrication and experimental test results were presented for a micro-electro-mechanical systems (MEMS)-based gas chromatography column. Compared with conventional column, this micro-gas chromatography column is suitable for on-line analysis and monitoring because of the small size, rapid analysis and other characteristics. These 0.5, 1 and 3 m GC columns were fabricated using a deep reactive-ion etching (DRIE) and were coated the stationary phase via a dynamic coating procedure. These GC columns perfectly separated the mixture of benzene, toluene and o-xylene in less than 200 s, where, the 3.0 m of the GC column achieved) a high resolution of 14.3 between toluene and o-xylene and yielded approximately 6160 plates. Moreover, the effect of separation performance for different column length were examined and compared. These GC columns are suitable for the application of a variety of disciplines, including environmental analysis, methane gas probes and homeland security.
3.Construction and implementation of training base for anesthesia specialized nurses based on IFNA evaluation criteria
Lin GUO ; Qiyue HE ; Yulan FANG ; Jianhai YU ; Yunwen TAN ; Jiali ZHAO ; Guizhi SUN
Chinese Journal of Medical Education Research 2021;20(4):475-478
Based on the International Federation of Nursing Anesthetists (IFNA) education and training base, our hospital has built a training base for anesthesia specialized nurses in Nanjing from the following aspects: the application for training base of anesthesia specialized nurses, the qualification and examination of students' and teachers' qualification, the settings of training curriculum, the examination contents and methods, and the evaluation of post-training effect. This article summarizes the construction experience of this base, therefore, providing support and standard for the training of anesthesia specialized nurses.
4.Hybrid procedure with cardiopulmonary bypass for muscular ventricular septal defects in children
Xuming MO ; Haitao GU ; Weisong ZUO ; Jiang SUN ; Wei PENG ; Jirong QI ; Li SHEN ; Jun DING ; Kaihong WU ; Jianhai XIA ; Zhenxi WANG ; Longbao QIAN
Chinese Journal of Thoracic and Cardiovascular Surgery 2011;27(5):264-266,270
Objective To summarize the technique and clinical experience of hybrid procedure under cardiopulmonary bypass (CPB) in children with muscular ventricular septal defect (mVSD). Methods From January 2006 to June 2010, 45 cases of mVSD underwent hybrid procedure with CPB. mVSDs were closed with devices under direct vision in 45 cases. Of them, there were 20 males and 25 females. They ranged from 52 days to 12 years [mean (2.05 ±2.48) year] in age and from 3 to 30 kg [(11.93 ±7.70)kg] in body weight. Preoperatively, most of children were highly susceptible to respiratory tract infections. The hybrid approach was used in all patients with CPB under the guidance of transesophageal echocardiography (TEE). The diameter of mVSDs ranged from 2 to 7 mm under TEE. Of 45 cases, 40 patients had increased rates of pulmonary blood flow. 29 patients had left axis deviation and 12 cases had sinus arrhythmia on electrocardiography (ECG). 19 had other congenital heart lesions, including transposition of great arteries in 1 case, tetralogy of Fallot in 2, pulmonary artery stenosis in 3, patent ductus arteriosus in 6, atrial septal defects in 6) and aorta coactation in 1. The quantity of VSDs were from 1 to 7 (single, in 7; two, in 24 case; three, in 8 case; four, in 5 case and seven, in lease. 37 patients were combined with pulmonary hypertension in our cohort. 38 patients with another large VSD and 19 with other congenital heart lesions were required surgical repair at sometime. Results The hybrid procedures were undertaken in all 45 cases of this cohort. All cases were successful and no deaths occurred during operation. A total of 48 devices were implanted in 45 patients, including single devices in 42 cases (device size ranged from 4 to 10 mm) and two devices in 3 cases (device size ranged from 4 -7 mm). The average time on CPB was (58.28 ±20.70) min , while aortic crossclamp time was(34. 94 ± 14.75) min. In addition, the time on mechanical ventilation postoperatively ranged from 2 hours to 6 days. Compared to the older children, 20 infante aged less than 8 monhad a significant difference in cardiac function in the early postoperative period. One infant was given up treatment because of serious infection. Anather cases recovered with the use of supportive treatment, such as using vasoactive agents, digoxin, inhaling nitric oxide, diuresis, and so on. The enteric-coated aspirin was given at dose of 5 mg ? kg -1. day -1 for a period of 3 to 6 months as usual postoperatively. All patients attended follow-up at 1 week, 1 month, 3 months, 6 months, 1 year and 2 years post-procedure. No major complications were encountered during this period. All cases were no instance of migration of any of the devices, residual shunt, aortic regurgitation, atrioventricular valve dysfunction, Ⅲo atrial-ventricular conduction block, new arrhythmia, and so on. There are no death in long-term follow-up. Conclusion Hybrid procedure is safe and effective for the closure of congenital heart defects in children.