1.Influence of Sodium Nitroprusside on Cell Motility of Outer Hair Cells of Guinea Pigs
Journal of Audiology and Speech Pathology 1998;0(03):-
Objective To study the changes of cell motility of outer hair cells in the cochlear of guinea pigs under treatment of sodium nitroprusside(SNP). Methods By using the whole cell patch clamp recording technique in normal external and internal cell solution, the cell motility of outer hair cells under stimulation of voltage was observed in different concentration of SNP. Results Sodium nitroprusside apparently inhibited outer hair cells' motility when SNP concentration was higher than 100 ?Mol/L ( P
2.EFFECT OF SESAMIN ON GLUCOSE METABOLISM IN HYPERLIPIDEMIA RATS
Jianbo AN ; Ruijuan ZHANG ; Ling ZHOU
Acta Nutrimenta Sinica 1956;0(02):-
Objective To study the effect of sesamin on glucose metabolism in hyperlipidemia rats. Method The hyperlipidemia SD rats were established by high lipid diet. These rats were intervened by sesamin for 7 w,and then their serum lipids were determined. Fasting blood glucose (FBS),glycosylated hemoglobin (HbA1c),insulin,and the pathological changes of pancreas were observed. Results Sesamin could reduce serum TC,TG,LDL-C,apoB and insulin levels,appropriately increase HDL-C and apoA contents (P
3.Changes in intensity of postoperative pain under ketamine anesthesia in children: a Meta-analysis
Zhaoduan LI ; Fen ZHOU ; Jianbo YU
Chinese Journal of Anesthesiology 2012;32(4):444-446
Objective To systematically review the changes in the intensity of postoperative pain under ketamine anesthesia in children.Methods We searched the Cochrane Library,PubMed,OVID,EMBASE,and Chinese Biomedical Database for prospective randomized controlled trials involving the changes in the intensity of postoperative pain under ketamine anesthesia in children.The quality of the studies was evaluated by the method recommended by Cochrane Collaboration.Evaluation indexes included pain score and analgesic consumption during 6 h after operation,pain score and analgesic consumption during 6-24 h after operation,duration of sensory block (caudal block),side effects during 24 h after operation (postoperative nausea and vomiting and psycho-mimetic manifestations).Meta-analysis was conducted using the Cochrane Collaboration's RevMan 5.0 software.Results Fifteen prospective randomized controlled trials involving 955 patients were included in our Meta-analysis.The patients were divided into 2 groups:control group ( n =455) and ketamine group ( n =500).The pain score and analgesic consumption during 6 h after operation were significantly decreased after general anesthesia with ketamine.The pain score during 6-24 h after operation and analgesic consumption during 6 h after operation were significantly decreased after local anesthesia with ketamine.The duration of sensory block was prolonged and the analgesic consumption during 6 h after operation was significantly reduced after caudal block with ketamine.There was no significant difference in the incidence of postoperative nausea and vomiting and psycho-mimetic manifestations between the two groups.Conclusion The intensity of pain and analgesic requirement during 6 h after operation are significantly reduced under ketamine anesthesia in children.
4.Relativity Experimental Study between the Anoxic Blood Vessel Constriction and Endothelium Dependent NO Deficiency.
Yongbo SUN ; Aoli SUN ; Jianbo ZHOU
Journal of Medical Research 2006;0(09):-
Objective To observe effect of large blood vessel hypoxia on the Wister rat′s NO activity. Methods Thoracic aorta rings model with full endothelium and removed endothelium of Wistar rat were prepared , hypoxia stimulated aorta rings and noted changes of constriction extent. Results Endothelium full , removed endothelium aorta rings by hypoxia contract extent difference was 598?42mg and 208?38mg, both had significance discrepancy (P0.05), and NTG made blood vessel contract to reduce range, reach 57.21% (P
5.The prevalence rate of three species of integrons in multi-drug resistant Pseudomonas aeruginosa and investigation of class Ⅰ integron structure in Jiangyin area
Feng LIU ; Zhongming LU ; Jianbo ZHOU
International Journal of Laboratory Medicine 2008;29(4):305-306,310
Objective To investigate the resistance rate of Pseudomonas aeruginosa to several commonly used antibiotics,as well as the prevalence status of three species of integrons in multi-drug resistant Pseudomonas aeruginosa from 2005 to 2006 in our hospital,and to identify the genetic structure of class Ⅰ integron in in our hospital.Methods Drug resistance slip method was applied to detecting the resistant rates of 100 isolates of Pseudomonas aeruginosa to ciprofloxacin,cefotaxime,gentamicin and imipenem.Boiling method was adopted to abstract DNA template of 100 isolates of Pseudomonas aeruginosa,and PCR assay adopted to identify the prevalence rate of three species of integrons and class Ⅰ integron structure.Results The resistant rates of 100 isolates of Pseudomonas aeruginosa to ciprofloxacin,cefotaxime,gentamicin,cefoxitin,tobramycin and imipenem were 32%,45%,82%,37%,39% and 43% respectively.The prevalence rates of three species of integrons was as follows:class Ⅰ 53%,Ⅱ 21% and Ⅲ 5%.Sequence analysis displayed there existed box gene dfrA17 and aadA2 in variable region of class Ⅰ integron.Conclusion The resistant rates of Pseudomonas aeruginosa to four drugs are elevated,especially to gentamycin.Multi-drug resistance may be partly due to prevalence of class Ⅰ integron.
6.Extraction of Volatile Oil from Marchantia Convoluta by CO_2 Supercritical Fluid Extraction and Analysis by GC-MS
Jianbo XIAO ; Chunshan ZHOU ; Hui CAO ;
Traditional Chinese Drug Research & Clinical Pharmacology 1993;0(03):-
Objective To optimize the experimental condition for CO 2 supercritical fluid extraction(SFE)of volatile oil from Marchantia convoluta andto analyse the extract.Methods Orthogonaltestwas applied.SFEtechnology was usedto optimize the extractionconditionfor volatile oilfrom Marchantia convoluta and the solventextractionwas useda s the control.The extract was analyzed by GC-MS and HPLC.Results The optimal extraction conditions f or the volatile oil were:pressure at15MPa,heatingtemperatureat50℃,addingt hemodifier ofalcohol30mLtoextractfor2h,flowingratebeing10L /hand theabsorbefa-cient solution being alcohol .Twent y -three peaks were isolated and 19components were identified,accounting 82.61%.Conclusion SFEmethodhas theadvantages of shorterextractiontimeandhighextractionefficiencyas comparedwiththet radi-tionalsolventextraction.
7.Diagnostic value of spectrum CT volume helical shuttle technology in detection of pulmonary arteriovenous malformations
Yue ZHOU ; Jianbo GAO ; Zhigang ZHOU ; Yonggao ZHANG ; Junqiang DONG
Journal of Practical Radiology 2015;(5):832-836
Objective To access the diagnostic value of volume helical shuttle (VHS)technology of spectrum CT in detection of the pulmonary arteriovenous malformations (PAVM).Methods Thirteen patients with PAVM confirmed by surgery and clinical data underwent CT pulmonary artery angiography with VHS technology,which were regarded as group A.The consecutive images at four different phases were gotten Meanwhile,other thirty patients underwent conventional CT pulmonary artery angiography using bolus tracking scan,regarded as Group B.The enhancement degrees of the pulmonary trunk were measured,and the image quality was also subjectively assessed by two radiologists separately,which were compared between two groups.Results In group A,the proportion of optimal phase in each of the four phases was 15.38% (2/13),46.15% (6/13),30.77% (4/13)and 7.7% (1/13),respectively.The mean CT value in pulmonary trunk was (329.21±41.63)HU in group A and (281.74±49.83)HU in group B,exhibiting no difference (P =0.989). The percentage of enhancement degree of pulmonary trunk more than 300 HU in group A was more than that in group B (P=0.000).However, the image quality of the main pulmonary artery,lobar pulmonary artery or segmental pulmonary artery was not significantly different between two groups (P >0.05).There were no statistically differences in mean DLP between group A of (715.54±195.37)mGy/cm and group B of (558.36±186.81)mGy/cm (t=3.737,P=0.068).Conclusion Spectrum CT VHS with higher image quality and enhancement degree is superior to conventional CT scan,which can be used to reduce the influence of individual circulation difference on image quality.
8.Comparison of efficacy of two surgical methods for Chiari anomalies with syringomyelia
Jianbo ZHOU ; Hongyu DIAO ; Boyang LI ; Siqi LIU ; Xinxing LI
Chinese Journal of Postgraduates of Medicine 2014;37(35):34-37
Objective To investigate the efficacy of foramen magnum decompression alone and foramen magnum decompression + Syrinx-shunt in the treatment of Chiari anomalies with syringomyelia.Methods Forty-nine Chiari anomalies with syringomyelia patients were selected,28 patients performed foramen magnum decompression alone (surgical method Ⅰ group),21 patients performed foramen magnum decompression + Syrinx-shunt (surgical method Ⅱ group).The treatment efficacy was evaluated by postoperative clinical effect and MRI review.Results In surgical method Ⅰ group,effective in 18 cases,invalid in 10 cases,the effective rate was 64.3% (18/28).In surgical method Ⅱ group,effective in 19 cases,invalid in 2 cases,the effective rate was 90.5%(19/21).There was statistical difference (x2 =4.45,P =0.034).Conclusion Foramen magnum decompression + Syrinx-shunt is effective in the treatment of Chiari anomalies with syringomyelia,which is applicable for these patients and has a more precise consequence than foramen magnum decompression alone.
9.Application of dual volume reconstruction translucent imaging in performing stent implantation for intracranial aneurysms
Xianghai ZHANG ; Jinhua CHEN ; Jianbo XIANG ; Hongye YAN ; Lin ZHOU
Journal of Interventional Radiology 2014;(6):466-469
Objective To investigate the application of dual volume reconstruction translucent imaging in performing stent- assisted coil embolization for intracranial aneurysm embolization treatment. Methods During the period from Nov. 2011 to Sep. 2012, a total of 30 patients with intracranial aneurysm were admitted to authors’ hospital. Stent-assisted coil embolization was carried out in all patients. The number of all the stent point-marks visualized on routine 2D-DSA, on rotational angiography (3D-RA) and on dual volume reconstruction translucent images were determined, and the results were compared between each other of the three imaging methods. Results A total of 34 stents (206 stent point-marks in total) were implanted in the 30 patients. Of the 206 stent point-marks, 2D-DSA, 3D-RA and dual volume reconstruction translucent image could clearly display 146 (70.8%), 123 (59.7%) and 190 (92.2%), respectively. Statistically significant difference in the displaying rate of the stent point-marks existed between each other among the three imaging methods (P < 0.05). Conclusion Dual volume reconstruction translucent imaging can distinctly display the location of the stent marks, which is of great value in guiding the performance of intracranial stent implantation surgery.
10.Value of advanced virtual monoenergetic technique in improving imaging quality of lliofemoral arteries
Hui SHI ; Zhigang ZHOU ; Yan WU ; Jianbo GAO
Journal of Practical Radiology 2017;33(8):1281-1284
Objective To investigate the value of advanced virtual monoenergetic technique(mono-plus) of dual-energy CT (DECT) in improving imaging quality of the lliofemoral arteries.Methods Forty consecutive patients underwent DECT scan.Mono-plus images (40 keV),optimal monoenergy images and mixed energy images were obtained by using Siemens Syngo.via VB10A workstation.CT values,signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and subjective image quality were calculated in the abdominal aorta,iliac artery,external iliac artery,femoral artery,profound femoral artery, lateral circumflex femoral artery,transversal branch of lateral circumflex femoral artery,medial circumflex femoral artery and profound branch of medial circumflex femoral artery and compared among the three groups.Results Compared with the optimal monoenergy and mixed energy groups,CT value and CNR of the 9 arteries were significantly higher in the mono-plus group (P<0.003).SNR of the transversal branch of lateral circumflex femoral artery and the profound branch of medial circumflex femoral artery showed no significant difference (P>0.05) among the threegroups,whereas SNR of the arties bigger than the 6th grade branch were significantly lower in the mono-plus group (P<0.05).The subjective image quality in the mono-plus group was significant better than the other two groups(P<0.001).Conclusion 40 keV mono-plus technique in DECT can improve the display of lliofemoral arteries especially the small and distal branches.