1.Clinical Features of Cerebral Infarction with or without Diabetes Mellitus
Ming ZHANG ; Jinsheng ZHANG ; Jiajing BI ; Zhengzheng HAN ; Yongxi HUANG
Chinese Journal of Rehabilitation Theory and Practice 2011;17(9):861-862
Objective To investigate the clinical features of cerebral infarction complicated with diabetes mellitus (DCI) compared withthose without diabetes mellitus (NCI). Methods 80 DCI and 86 NCI hospitalized patients were reviewed with their serumal glucose, lipid,uric acid, hemorheology and carotid ultrasound. Results The total cholesterol, low density lipoprotein and uric acid were significantly higherin DCI group than in NCI group (P<0.05), while high density lipoprotein was significantly lower (P<0.05). There were significant differencesbetween these two groups in Hemorheological indicators except hematokrit (P<0.01). The carotid intima media thickness (IMT) wassignificantly higher in the DCI group than in the NCI group (P<0.05). Conclusion DCI patients suffered in more serious lipid, uric acid,hemorheological disorder, and IMT compared with NCI.
2.Effects of Cervical Fusion Surgery by Different Methods on Stability in Upper Cervical Spine with Jefferson Fracture
Houhai BI ; Gaiping ZHAO ; Haifei XU ; Ziqiang DONG ; Jiajing YANG ; Hongjie WANG
Journal of Medical Biomechanics 2021;36(2):E231-E237
Objective To establish the finite element model of upper cervical vertebrae C0-3 with Jefferson fracture, and to analyze the influence of posterior atlantoaxial fusion (PSF) and occipitocervical fusion (OCF) on biomechanical properties of the vertebral body and mechanical conduction of the screw-rod system. Methods Based on CT images, the C0-3 segment Jefferson fracture model of human upper cervical spine was established. PSF, OCF1 and OCF2 internal fixation were performed according to surgical plan in clinic, and 50 N concentrated force and 1.5 N·m torque were applied to bottom of the occipital bone. The stress distribution and range of motion (ROM) of the cervical vertebral body, the maximum stress of the screw-rod system and the stress distribution of the intervertebral disc for C0-3 segment during flexion, extension, bending and rotation of the upper cervical spine were studied. Results Compared with PSF, the ROM of OCF1 and OCF2 vertebral bodies increased, and the stress of the nail rod decreased. OCF had a better fixation effect. Conclusions PSF, OCF1 and OCF2 fixation method can reduce the upper cervical ROM and restore stability of the upper cervical spine, which make stress distributions of the vertebral body and intervertebral disc tend to be at normal level. The research result can provide a theoretical basis for clinical surgery plan.