1.A low-cost intraocular lens snare
Dy Widmark A ; Chuanico Rudolfo U ; Eusebio Jr Jesus B
Philippine Journal of Ophthalmology 2001;26(2):-
Posterior dislocation of an intraocular lens into the vitreous cavity is uncommon but is a difficult problem to manage. Various techniques have been described but most of them entail the use of specially manufactured expensive instruments. The aim of this study, therefore, is to develop a low-cost surgical snare in retrieving a dislocated posterior chamber intraocular lens (PCIOL). The snare consists of a 6.0 polypropylene suture threaded into a 21-gauge flute cannula. The loop of suture formed is used to secure the haptics of the lens. This is used after a pars plana vitrectomy to retrieve the dislocated PCIOL. The snare is easy to make with inexpensive disposable surgical materials. (Author)
Human
;
Male
;
Middle Aged
;
SURGERY
;
CANNULA
2.Macular pigment optical density in healthy eyes of Filipino adults
Jacqueline Mupas ; Jesus Eusebio Jr. ; Reynaldo Javate ; Ernesto Pablo Jr.
Philippine Journal of Ophthalmology 2015;40(2):93-96
Objective:
To determine the range of macular pigment optical density (MPOD) levels in healthy Filipino adults
using both the MPS II and the macuscope and to investigate whether age and sex were related to inter-subject
variations in MPOD.
Methods:
This was a prospective, cross sectional study of 168 healthy Filipino patients who underwent heterochromic
filter photometry to measure macular pigment levels using the MPS II and the macuscope. The MPOD levels were
averaged per age group and analyzed as to variations among age and gender.
Results:
One hundred thirty (130) and thirty-eight (38) patients underwent MPS II and macuscope testing
respectively. The mean MPOD level for MPS II was 0.39(±0.16) and for macuscope 0.27(±0.07). MPOD values
were similar across all age groups and gender, but they were lower when measured with the macuscope.
Conclusions
MPOD levels measured among healthy Filipino adults were lower with the macuscope compared
to the MPS II. These differences should take into consideration the differences in apparatus and techniques of
measurement.
Macular Degeneration
;
Zeaxanthins