1.Stress analysis on the alveolar bone of cantilever bridges replacing maxillary lateral incisor.
The Journal of Korean Academy of Prosthodontics 1993;31(3):303-316
No abstract available.
Incisor*
2.The position of the incisors in correlation to anb angle, procumbency and inclination in korean normal occlusion.
Korean Journal of Orthodontics 1971;2(1):7-14
No abstract available.
Incisor*
3.Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor.
Xiaowei LI ; Chaochao REN ; Zheyao WANG ; Pai ZHAO ; Hongmei WANG ; Yuxing BAI
The Korean Journal of Orthodontics 2016;46(2):65-72
OBJECTIVE: The purposes of this study were to measure the orthodontic forces generated by thermoplastic aligners and investigate the possible influences of different activations for lingual bodily movements on orthodontic forces, and their attenuation. METHODS: Thermoplastic material of 1.0-mm in thickness was used to manufacture aligners for 0.2, 0.3, 0.4, 0.5, and 0.6 mm activations for lingual bodily movements of the maxillary central incisor. The orthodontic force in the lingual direction delivered by the thermoplastic aligners was measured using a micro-stress sensor system for the invisible orthodontic technique, and was monitored for 2 weeks. RESULTS: Orthodontic force increased with the amount of activation of the aligner in the initial measurements. The attenuation speed in the 0.6 mm group was faster than that of the other groups (p < 0.05). All aligners demonstrated rapid relaxation in the first 8 hours, which then decreased slowly and plateaued on day 4 or 5. CONCLUSIONS: The amount of activation had a substantial influence on the orthodontic force imparted by the aligners. The results suggest that the activation of lingual bodily movement of the maxillary central incisor should not exceed 0.5 mm. The initial 4 or 5 days is important with respect to orthodontic treatment incorporating an aligner.
Incisor*
;
Relaxation
4.Comparative study in fracture strength of zirconia cores fabricated with three different CAD/CAM systems.
Eon Sick SHIN ; Young Soo LEE ; Won Hee PARK
The Journal of Korean Academy of Prosthodontics 2008;46(1):22-30
PURPOSE: The purpose of this study is to compare three different CAD/CAM systems through the fracture strength of zirconia core and to evaluate the clinical availability of each system. MATERIAL AND METHODS: The following three groups of 30 maxillary mesial incisor core for all-ceramics(each group 10) were fabricated as follows: group 1. Adens(R) CAD/CAM system, group 2. Cerasys(R) CAD/CAM system, group 3. 3M LAVA(R)CAD/CAM system. All specimens were manufactured consistently thickness 0.5mm and relief 40 micrometer. Specimens were subjected to compressive loading on the lingual area by Z250/SN5S(R). Each group's mean and standard deviation were calculated and Kruskal Waillis test, Wilcoxon Rank Sum test were utilized to find out the relationship among the groups. RESULTS: The results were as follows: 1. The mean fracture strength of Adens(R) system was 615.89+/-156.1N, the Cerasys(R) system was 863.98+/-151.5N, and the 3M LAVA(R) system was 1143.1+/-286.6N. 2. The fracture strength of the systems showed the significant statistical differences in order of 3M LAVA(R) system, Cerasys(R) system, Adens(R) system. CONCLUSION: In this study, in spite of the differences among the groups, every group showed clinically useful results. It is necessary to study further clinical experiments on a long term basis.
Incisor
;
Zirconium
5.A study on the marginal fit of CAD/CAM 3-unit bridges.
Ki Hong LEE ; In Sung YEO ; Sung Hun KIM ; Jung Suk HAN ; Jai Bong LEE ; Jae Ho YANG
The Journal of Korean Academy of Prosthodontics 2011;49(2):101-105
PURPOSE: The purpose of this study was to assess the marginal fit of three-unit bridges produced using LAVA CAD/CAM (computer-aided design/computer-aided manufacturing) system and conventional PFG in vitro. MATERIALS AND METHODS: #11, 13 resin teeth were prepared on dentiform, then duplicated. Twenty resin models were fabricated, ten for PFG 3-unit bridges and ten for LAVA 3-unit bridges. Each bridge was cemented on the resin model. Marginal discrepancy was measured with stereoscopic microscope (Nikon DS-Fi 1, Nikon, Japan) at a magnification of x75. Independent t-test was done for the statistical analysis. RESULTS: The mean marginal discrepancy values and standard deviations of the PFG bridges was 97.1 +/- 18.7 microm for incisors, 76.6 +/- 21.8 microm for canines; that of the LAVA bridges was 90.4 +/- 26.7 microm for incisor, 110.2 +/- 30.2 microm for canines. The mean marginal discrepancy between PFG and LAVA for incisor did not show significant difference (P>.05). But for canine, the mean marginal discrepancy of PFG bridges was smaller than that of LAVA bridges (P<.05). CONCLUSION: The LAVA CAD/CAM 3-unit bridges and the PFG 3-unit bridges showed clinically acceptable marginal discrepancy.
Incisor
;
Tooth
6.Incisor inclination indicator for anterior torque control during retraction in lingual orthodontic treatment.
Ryoon Ki HONG ; Tae Gun KIM ; Tae Woo KIM
Korean Journal of Orthodontics 2004;34(6):544-554
A device called incisor inclination indicator to control the axial inclinations of the incisors in the diagnostic setup is introduced. It is used to control the retraction of the maxillary and mandibular incisors. In this article, we describe the use of the incisor inclination indicator to prescribe adequate torque into the anterior lingual brackets and evaluate the results of treatment in a bimaxillary dentoalveolar protrusion case that underwent orthodontic treatment with the pretorqued anterior lingual brackets. Retraction of the maxillary and mandibular incisors was achieved with careful control of the axial inclination. It is indicated that the use of the incisor inclination indicator is an effective adjunctive laboratory procedure for anterior torque control during retraction in lingual orthodontic treatment.
Incisor*
;
Torque*
7.Shear bond strength and failure patterns according to the material of resin base in indirect racket bonding.
Man Bae JEON ; Hyeon Shik HWANG ; Jong Chul KIM
Korean Journal of Orthodontics 1998;28(2):277-284
The purpose of this study was to evaluate the propriety of making use of the light-cured resin base in indirect bracket bonding technique by study of shear bond strength and failure patterns according to the material of resin base. Metal brackets were bonded to the stone models of specimens involving bovine lower incisor with chemical-cured(Excel), light-cured(Light-Bond) and thermal-cured(Therma-Cure) resin. They were transferred to the specimens and bonded using sealant. The shear bond strength was tested on Instron. After bracket removal, the bracket base was examined and assessed with the adhesive remnant index(ARI). The results were as follows: 1. No significant differences in shear bond strength were found among the three groups (P>0.05). 2. No significant differences in Alts score were found among the three groups (P>0.05). The above results suggest that light-cured resin base in addition to chemical-cured and thermal-cured resin bases is useful in the indirect bonding technique.
Adhesives
;
Incisor
8.Use of autonomous maximal smile to evaluate dental and gingival exposure.
Shuai WANG ; Hengzhe LIN ; Yan YANG ; Xin ZHAO ; Li MEI ; Wei ZHENG ; Yu LI ; Zhihe ZHAO
The Korean Journal of Orthodontics 2018;48(3):182-188
OBJECTIVE: This study was performed to validate the autonomous maximal smile (AMS) as a new reference for evaluating dental and gingival exposure. METHODS: Digital video clips of 100 volunteers showing posed smiles and AMS at different verbal directives were recorded for evaluation a total of three times at 1-week intervals. Lip-teeth relationship width (LTRW) and buccal corridor width (BCW) were measured. LTRW represented the vertical distance between the inferior border of the upper vermilion and the edge of the maxillary central incisors. Intraclass correlation coefficients (ICCs) for reproducibility, and the m-value (minimum number of repeated measurements required for an ICC level over 0.75), were calculated. RESULTS: LTRW and BCW of the AMS were 1.41 and 2.04 mm, respectively, greater than those of the posed smile (p < 0.05), indicating significantly larger dental and gingival exposure in the AMS. The reproducibility of the AMS (0.74 to 0.77) was excellent, and higher than that of the posed smile (0.62 to 0.65), which had fair-to-good reproducibility. Moreover, the m-value of the AMS (0.88 to 1.05) was lower than that of the posed smile (1.59 to 1.85). CONCLUSIONS: Compared to the posed smile, the AMS shows significantly larger LTRW and BCW, with significantly higher reproducibility. The AMS might serve as an adjunctive reference, in addition to the posed smile, in orthodontic and other dentomaxillofacial treatments.
Incisor
;
Volunteers
9.Orthodontic treatment in the rehabilitation of congenitally Maxillary Lateral Incisors Agenesis with multiple maxillary anterior diastema
Bunga Fatimah ; Ida Bagus Narmada
Acta Medica Philippina 2019;53(6):539-546
The maxillary lateral incisor is the second most common congenitally absent tooth. This is a case of a 25-year-old with maxillary lateral incisors agenesis, multiple maxillary anterior diastema. Pre-adjusted technique was used, gingivectomy and frenectomy to release tooth movement. Patient’s profile was straight, interdental relationship was class I, enlarged space of maxillary lateral incisors, space was replaced by prostheses. The treatment of maxillary lateral incisors agenesis responsible for orthodontic, periodontic and prosthodontic achieved a pleasant aesthetic and function.
Diastema
;
Incisor
10.Marginal fit of the auro galvano crown system made using the electroforming technique.
Jae Ho YANG ; Tae Jin SONG ; Jung Suk HAN ; Jae Bong LEE ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 2004;42(6):679-683
STATEMENT OF PROBLEM: There have been few studies about the marginal fit of Auro Galvano Crowns. PURPOSE: The purpose of this study was to compare the marginal fit of the anterior single restorations. MATERIAL AND METHODS: The in vitro marginal discrepancies of metal-ceramic, Auro Galvano Crown and coping were evaluated and compared. The Auro Gavano Crowns were made from one extracted maxillary central incisor prepared by milling machine. 30crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. RESULTS: Mean marginal gap dimensions and standard deviations at the marginal opening for the anterior single crowns were 74+/-21micrometer for the control (metal-ceramic restoration), 45+/-11 micrometer for Auro Galvano Crown coping, and 51+/-9 micrometer for the Auro Galvano Crown. CONCLUSIONS: Auro Galvano Crown showed significantly smaller (P< .05) marginal gap than the control. Ceramic application did not significantly affected the marginal fit of Auro Galvano Crown. (P> .05)
Ceramics
;
Crowns*
;
Incisor