1.A COMPARATIVE STUDY OF THE TERATOGENIC ACTIVITY OF FOUR THIADIAZOLE COMPOUNDS IN PREGNANT RATS
Fangyuan WANG ; Huiyi YONG ; Yuxin YOU ; Ying ZHONG
Acta Anatomica Sinica 1954;0(02):-
Bis-A-S-TDA;This may be due to the presence of different active groups in the four compounds.
2.Diagnostic value of ultra-high b-value diffusion-weighted imaging in prostate cancer
Kun ZHANG ; Ruiping ZHANG ; Yong GUO ; Xiaojing ZHANG ; Yanguang SHEN ; Yan ZHONG ; Haiyi WANG ; Huiyi YE
Cancer Research and Clinic 2018;30(5):298-302
Objective To explore the value of ultra-high b-value diffusion-weighted imaging(DWI) in diagnosis of prostate cancer. Methods According to inclusion and exclusion criteria, 73 consecutive examinees in Chinese PLA General Hospital from June 2014 to May 2015 were screened. Written informed consent was obtained from all patients. T2WI, conventional DWI with b-value of 1 000 s/mm2and ultra-high b-value DWI with 2 000 s/mm2and 3 000 s/mm2were performed in each examinee. Images were interpreted and were corresponding to histological results conducted by ultrasound guided prostate systematic biopsy. Reference biopsy as the gold standard,the sensitivity,specificity, positive predictive value(PPV) and negative predictive value (NPV) were calculated for each image. Sensitivity and specificity differences between ultra-high b-value DWI and conventional DWI were analyzed. The areas under the curves (AUCs) between ultra-high b-value DWI and other modalities were compared. Results The sensitivity and specificity for ultra-high b-value DWI were 92.5 % and 68.8 % with b-value of 3 000 s/mm2, and they were 88.1 % and 53.1 % for 2 000 s/mm2in peripheral zone. The sensitivity and specificity for ultra-high b-value DWI were 88.0 % and 88.2 % with a b-value of 3 000 s/mm2, and they were 80.0 % and 52.9 % for 2 000 s/mm2in transition zone. The values of sensitivity for ultra-high b-value DWI were significantly higher than those for conventional DWI both in peripheral zone and transition zone (all P <0.000 1). The detection of lesions was comparable with ultra-high b-value DWI at 2 000 s/mm2and 3 000 s/mm2in peripheral zone (P >0.05), whereas the value of specificity for 3 000 s/mm2were significantly higher than that for 2 000 s/mm2in transition zone (P<0.000 1). PPV and NPV for 3 000 s/mm2were significantly higher than those for the other three modalities both in peripheral zone(86.1 % and 81.5 %) and transition zone (91.7 % and 83.3 %). In peripheral zone, the AUCs were 0.591, 0.553, 0.698 and 0.806 in T2WI, conventional DWI and ultra-high b-value DWI at 2 000 s/mm2 and 3 000 s/mm2respectively, for the diagnosis of transition zone cancer were 0.693, 0.506, 0.665 and 0.881 respectively, and the AUCs for the ultra-high b-value with 3 000 s/mm2were the largest. Conclusion Ultra-high b-value DWI is an accurate and reliable method in the diagnosis of prostate cancer.
3.Application of Linear Accelerator on Boarding Kilovolt Fan Beam CT and Megavolt Cone Beam CT System on Set-up Errors During Radiation Treatment
Yong ZHOU ; Zeying JIANG ; Baofeng SU ; Jianfeng ZHOU ; Qian WANG ; Anting WANG ; Jingxian LIU ; Yan XUE ; Huiyi FENG ; Xiaoliang WU ; Mingxing XIAO ; Wenyong TAN
Cancer Research on Prevention and Treatment 2023;50(11):1097-1102
Objective To quantify the setup errors for the different anatomical sites of patients who received intensity-modulated radiotherapy (IMRT) with linear accelerator on-board kilovolt fan beam CT(kV-FBCT) as non-isocenter IGRT and megavolt cone beam CT (MV-CBCT) as isocenter IGRT. Methods A retrospective analysis was performedon 70 patients who underwent radiotherapy, kV-FBCT, and/or MV-CBCT scans after each routine setup prior to IMRT. The average displacement (M), systematic error (Σ), and random error (б) at different treatment sites in the left-right, anterior-posterior, and cranial-caudal directions were calculated according to the individual displacements. The formula 2.5Σ+0.7б was used to estimate the PTV margin in respective direction. For each single patient, the root mean square in three directions was used as 3D displacement. Results A total of 1130 displacements were recorded in the 70 patients. The PTV margin was estimated to be 1.9-3.1 mm in head and neck cancer, 2.8-5.1 mm in thoracic cancer, 4.6-5.1 mm in breast cancer, 3.0-5.5 mm in upper abdominal cancer, and 3.5-6.8 mm in pelvic tumor. For the 3D mean displacements, the head and neck, thoracic, breast, upper abdominal, and pelvic cancer were 2.4±1.0, 4.0±1.6, 4.1±2.0, 4.6±2.1, and 4.6±2.1 mm, respectively. The average 3D displacement obtained by kV-FBCT and MV-CBCT were 4.1 and 3.4 mm, respectively (
4.Uniaxial endoscopic intervertebral fusion combined with pedicle screw fixation in treatment of lumbar degenerative diseases
Long TANG ; Jiazhuang ZHENG ; Fandong WANG ; Yuanbin LIU ; Zhaojun SONG ; Zhi ZHANG ; Miao WANG ; Yong ZHOU ; Huiyi LIU ; Yu CHEN
Chinese Journal of Tissue Engineering Research 2024;28(24):3873-3878
BACKGROUND:With the rapid development of minimally invasive spinal surgery and enhanced recovery after surgery,endoscopic intervertebral fusion techniques have gradually emerged and been widely used in clinical practice in recent years. OBJECTIVE:To analyze the early clinical efficacy of uniaxial spinal endoscopic intervertebral fusion combined with posterior percutaneous pedicle screw fixation in the treatment of lumbar degenerative diseases. METHODS:135 patients with lumbar degenerative diseases treated by uniaxial spinal endoscopic intervertebral fusion combined with posterior percutaneous pedicle screw fixation in the Suining Central Hospital from October 2020 to December 2021 were enrolled in this study.There were 59 males and 76 females,aged 47-79 years.The lower limb and lumbar pain was evaluated by visual analog scale and lumbar function was assessed by Oswestry disability index before the operation,1 week,1,and 6 months after the operation,and at the end of follow-up.The overall pain recovery of patients was evaluated by the scoring criteria for low back pain surgery of Spine Group of Chinese Orthopedic Association and the lumbar physiological curvature and intervertebral fusion were evaluated on lumbar lateral X-ray preoperatively and at the end of follow-up. RESULTS AND CONCLUSION:(1)The 135 patients were followed up for(17.8±3.0)months after surgery.There was 1 case of endplate injury,1 case of cerebrospinal fluid leakage,1 case of nerve root injury,1 case of intervertebral cage subsidence and displacement,1 case of chronic infection,and 1 case of pedicle screw rupture.The complication rate was 5.2%.(2)The lumbar visual analog scale score and Oswestry disability index significantly decreased in the waist and lower limbs at various time points postoperatively compared with those preoperatively in 135 patients(P<0.05).The scoring criteria for low back pain surgery of the Spine Group of the Chinese Orthopedic Association were significantly better at the last follow-up than that preoperatively in 135 patients(P<0.05).(3)At the last follow-up,there was no significant difference in physiological curvature of lumbar vertebra as compared with that preoperatively in 135 patients(P>0.05),with a fusion rate of 95.8%.(4)It is concluded that uniaxial spinal endoscopic intervertebral fusion combined with posterior percutaneous pedicle screw fixation in the treatment of lumbar degenerative diseases has shown satisfactory early clinical results and is a highly safe minimally invasive spinal surgery mode.