1.Effect of intravenous fluid infusion combined with water throuth gastrointestinal tract on treatment of patients with hyperosmolar hyperglycemic state
Kai-Ning CHEN ; Yong-Yi GAO ; Tuan-Yu FANG ; Dao-Xiong CHEN ; Hui-Biao QUAN ; Hai-Wei LIU ;
Chinese Journal of Primary Medicine and Pharmacy 2006;0(09):-
Objective To investigate the effect of intravenous fluid infusion combined with water throuth gastrointestinal tract in treating the patients with hyperosmolar hyperglycemic state(HHS).Methods 30 HHS pa- tients were recruited.All the patients were given water throuth gastrointestinal infusion while they were administrat- ed continuously intravenous infusion.Laboratory parameters such as serum natrium,serum potasium,serum glucose and serum osmolarity ect were monitored at the admission and after treatment.Results Serum glucose and serum osmolarity of HHS patients were decreased smoothly at the speed of less than 3 mmol?L~(-1).h~(-1)during the first 12 hours after treatment.After 48 hour-treatment,serum natrium,serum potassium and serum osmolarity recovered to normal levels except 2 deaths,serum glucose decreased to(10.8?5.2)mmol/L.Conclusion Intravenous fluid infu- sion combined with water throuth gastrointestinal tract for the patients could lower smoothly serum glucose and serum osmolarity and decrease the mortality of the HHS patients.
2.Observation on the effect of population-based immunization of influenza A (H1N1)2009 split-virus vaccine.
Xin-hong XU ; En-jie LU ; Yan-hui LIU ; Yue-hong WEI ; Ji-bin WU ; Gui-hua HUANG ; Qing CAO ; Hui QUAN ; Jian-xiong XU ; Yan-shan CAI ; Tie-gang LI ; Biao DI ; Ming WANG
Chinese Journal of Epidemiology 2010;31(5):587-588
3.Frequency Characteristics of AEPs in Normal Young Adults and Comparison of Their Response Threshold and Pure Tone Audiometry Threshold.
Long Long CHENG ; Fang Liang LUO ; Yan He XIONG ; Fu Quan JIA ; Peng TANG ; Wei LIU ; Biao ZHANG ; Ji Hui LIU ; Hai Xia WANG
Journal of Forensic Medicine 2020;36(3):305-310
Objective The tests of three types of auditory evoked potentials (AEPs) were performed on normal young adults, to understand the frequency characteristics of different testing methods and the relationship between response threshold and pure tone audiometry threshold of different methods, and to discuss the forensic value of 3 types of AEPs to evaluate hearing function. Methods Twenty normal young adults were selected, their standard pure tone audiometry threshold, short-term pure tone audiometry threshold and the response threshold of 3 types of AEPs (tone burst-auditory brainstem response, 40 Hz auditory event-related potential and slow vertex response) at 0.5 kHz, 1.0 kHz, 2.0 kHz and 4.0 kHz were recorded. The relationship between the response threshold and standard pure tone audiometry threshold, short-term pure tone audiometry threshold of 3 types of AEPs at different frequencies as well as the differences between different types of AEPs were analyzed. Results The short-term pure tone audiometry threshold was higher than the standard pure tone audiometry threshold at each frequency. The response threshold and standard pure tone audiometry threshold of the 3 types of AEPs all had a certain correlation, and the response threshold of the 3 types of AEPs was higher than short-term pure tone audiometry threshold and standard pure tone audiometry threshold at each frequency. The differences in the differences between the response threshold and standard pure tone audiometry threshold of the 3 types of AEPs at different frequencies had statistical significance. Linear regression mathematical models were established to infer the standard pure tone audiometry threshold (hearing level) from response threshold (sound pressure level) of 3 types of AEPs of normal young adults. Conclusion When using response threshold of different types of AEPs to estimate pure tone audiometry threshold, conversion and correction are needed. Combined use of different types of AEPs could improve the accuracy of hearing function evaluation.
Audiometry, Evoked Response
;
Audiometry, Pure-Tone
;
Auditory Threshold
;
Evoked Potentials, Auditory
;
Evoked Potentials, Auditory, Brain Stem
;
Hearing
;
Humans
;
Young Adult
4.Consensus by Chinese Expert Panel on-Resistant and-Persistent Infection.
Man-Li QI ; Yuan-Li GUO ; Qian-Qiu WANG ; Xiang-Sheng CHEN ; Jian-De HAN ; Xiao-Hong SU ; Wen-Hui LUN ; Hao CHENG ; Jin-Hua XU ; Hong-Qing TIAN ; Li CHEN ; Zhi-Yuan YAO ; Wen-Li FENG ; Juan JIANG ; Ping-Yu ZHOU ; Xian-Biao ZOU ; Hong-Hui XU ; Wei-Min SHI ; Jun LIU ; Lin ZHU ; Quan-Zhong LIU
Chinese Medical Journal 2017;130(23):2852-2856
5.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve