1.Aspheric topographical features of the anterior surface of the human crystalline lens
Guang-Yu, YANG ; Huai-Jin, GUAN
International Eye Science 2008;8(10):1968-1971
AIM: To investigate the topography of the anterior surface of the human crystalline lens. ·METHODS: A Non-contact three-coodinate measuring system was utilized to scan the anterior surfaces of 8 human eye lenses in vitro. Acquired data were processed and computer models of the anterior lens surfaces were made using the program (Surfacer v 10.0). The to-pography of the anterior lens surfaces were established. Radii of curvature were measured at preset spots over the lens surfaces and two way analysis of variance was performed. The data were analysed to determine whether the radius of curvature varied systematically with the position on the lens surface from which the measurement was made. Lens surface asymmetric index (LSAI) was defined and calculated. The vertical and horizontal meridians of the modeled lens were calculated, and the best curve fit to any conic section was determined. ·RESULTS: The topography of the anterior lens surface indicated that the central zone (the central radius of curvature is (9.09±0.80)mm was steeper than that of the peripheral zone(17.05±2.20)mm. Two way analysis of variance of the radii of curvature at preset spots over the lens surfaces showed that the differences were statistically significant (P < 0.05). Curve regression of radii of curvature at preset spots and their distances to the surface center revealed that the correlation of them was the third power function. LSAI increased steadily from the lens surface center(0.013±0.005) to the periphery(0.184± 0.065). The dots on the horizontal and vertical meridians were fit to four kinds of curves, and the determinate coefficient of hyperbola fit were the largest (0.9989-0.9999). ·CONCLUSION: The anterior lens surface is imperfectly rotational symmetric. Moreover, the nearer to the center, the more rotational symmetric it is. Radii of curvature increase nonlinearly from the surface center to the periphery. Anterior lens surface is typically hyperbolic.
2.Experimental study on surface modification of intraocular lens by cyclosporine A-loaded chitosan nanoparticle
Jian-feng, YU ; Huai-jin, GUAN
Chinese Journal of Experimental Ophthalmology 2013;31(10):935-939
Background Posterior capsular opacification (PCO) following cataract extracapsular extraction is a major cause of the reduction of visual acuity.Topical administration of eye drops is a research hotspot for the prevention of PCO.Objective This study was to evaluate the release of cyclosporine A-loaded chitosan nanoparticles (CyA-CS-NP) by ionic gelation in vitro and its feasibility of modification of the surface of polymethylmethacrylate intraocular lens (PMMA IOL) with CyA-CS-NP.Methods The CS-NP and CyA-CS-NP were prepared by ionic gelation of CS with sodium tripolyphosphate.The characteristics of CS-NP,such as the appearance and mean size,and drug entrapment efficient (EE),loading capacity (LC),and the drug release were studied ; the CyA content on the IOL surface was detected by high performance liquid chromatography (HPLC).The IOL surface modified with CyA-CS-NP was observed by scanning electron microscope and X-ray photoelectron spectroscopy technique (XPS),the changes of elements and chemical bond types between simple plasma processed IOL and CyA-CS-NP modified IOL were analyzed.The transmittance at the wavelength of 360-490 nm and refraction of IOL were detected using back focal length method and spectrophotometer,and the effective resolution of IOL was evaluated according to the instruction of ISO/CD 11979-2.Loops anti fatigue test of IOL referred to the criteria of ISO/CD 11979-3.Results The CS-NP and CyA-CS-NP showed monodisperse,uniform appearance similar to spherical shape with a mean size of (158±18) nm and (219±29) nm,respectively.The CyA-CS-NP had high CyA association efficiency and loading capacity (64.2% and 7.6%).In vitro release study revealed a fast release on the first day followed by a increased drug release during an 11-day following up.The sustained release was approximately 46.6% at day 1 and 77.7% at day 12,respectively.The surface of IOLs with cling film was smooth without CS-NP;while the edge of IOLs appeared a layer of CyA-CS-NP after modification.XPS analysis displayed some elements such as phosphonium,CNH2 and O =CN that appeared on the modified surface,indicating that CyA-CS-NP existed on the surface of IOLs edge.The mean quality of CyA on three IOLs surface after modification was 171.88 μg.The diopter,distinguishing ability and transmittance of modified IOL were (16.64±0.23) D,(90.28 ± 0.25) % and (73.57 ±0.62) %,and those of unmodified IOL were (16.62±0.29) D,(90.28±0.21) %,(73.61±0.60)%,without significant differences between them (t =0.381,0.078,2.291,all at P > 0.05).The antifatigue ability of loops complied with the criteria of ISO/CD 11979-3.Conclusions The optical property and antifatigue ability of loops of the edge-modified IOLs by CyA-CS-NP reach the normal standard and meet the requirement of clinic application.The edge-modified IOLs by CyA-CS-NP can be a delivery system for intraocular drug release.
3.Abdominal acupuncture as main for vertigo.
Chinese Acupuncture & Moxibustion 2011;31(9):810-810
Abdomen
;
Acupuncture Therapy
;
methods
;
Adult
;
Aged
;
Aged, 80 and over
;
Female
;
Humans
;
Male
;
Medicine, Chinese Traditional
;
Middle Aged
;
Vertigo
;
therapy
4.Study on drying technology of Tiaogan Granules
Di WANG ; Fuxia JIA ; Huai GUAN ; Jiang LI
Chinese Traditional Patent Medicine 1992;0(08):-
Objective: To seek the optimum technology of drying and to solve the problem of powder sticking clump. Methods : On the basis of major drying condition, such as duration of drying, temperature of drying, evaluating different drying technology; On the basis of the quantity of the powder sticking on the wall and the hygroscopicity of one, investigating different excipients how to affect the spray drying. Seeking the optimum kinds and quantity of excipients. Results : The best properties of the granules are from the spray drying process. ?-cyclodextrin and lactose have the effects on solving the powder sticking on the wall. Conclusion : The spray drying process is the optimum one. Adding 3~5 percent of ?-cyclodextrin has an effect on improving the phenomenon of powder sticking on the wall in process of the spray drying.
5.Factorial Validity And Reliability Of The Simplified-Chinese Version Of Snaith-Hamilton Pleasure Scale : A Study Among Depressed Patients At An Out-Patient Clinic In Malaysia
Anne Yee ; Huai Seng Loh ; Chong Guan Ng
ASEAN Journal of Psychiatry 2014;15(1):66-71
The Snaith-Hamilton Pleasure Scale (SHAPS) is a self-assessment scale designed to evaluate anhedonia in various psychiatric disorders. To facilitate its use in Malaysian settings, our current study aimed to examine the
validity of the Simplified-Chinese translated version of the SHAPS (SHAPS-SC) in a group of subjects at a university out-patient clinic. Method: A total of 40
depressed patients were recruited in this cross sectional study. They were given both the Simplified Chinese and Malay versions of SHAPS, General Health Questionnaire 12 (GHQ-12) and Beck Depression Inventory (BDI) to assess their hedonic state, general mental health condition and level of depression. Results: Our study showed that SHAPS-SC had impressive internal consistency (Cronbach’s alpha 0.84) and concurrent validity, and fair parallel-forms
reliability (Pearson’s correlation 0.39). Conclusion: SHAPS-SC demonstrate good psychometric properties in the evaluation of hedonic state among a group of Chinese speaking depressed patients in an out-patient setting. It is easy to administer and suitable as a valid and reliable questionnaire in assessing anhedonia among depressed patients in Malaysia.
Patients
;
Depression
;
Outpatient Clinics, Hospital
6.The survey of cataract surgery quality on blindness prevention in Jiangyan County
Ji-Bo ZHOU ; Huai-Jin GUAN ; Hai-Yan GU ;
Ophthalmology in China 1993;0(03):-
Objective To explore the cataract surgery quality on blindness prevention and postoperative problems in village in short period. Design Population-based survey. Participants 251 cases(254 eyes) received operation and 131 cases(134 eyes)were surveyed 6-month postoperatively. Methods Patients were examined 6-month after the small incision extracapsular cataract extraction and intra ocular lens(IOL) implantation. Examinations were conducted by a special oculist including far vision, near vision, external in- spection, anterior segment, posterior segment, intraocular pressure. Main Outcome Measures Visual acuity, intraocular pressure, diopter, eye complications of surgery. Results Naked far vision of the operated eye more than or equal to 0.3 was 41.8%, naked far vi- sion of the eye more than or equal to 0.05 was 82.8%; corrected far vision more than or equal to 0.3 was 64.2%, corrected far vision more than or equal to 0.05 was 92.3%. Naked near vision more than or equal to 0.1 was 79.9%, corrected near vision more than or e- qual to 0.1 was 85.8%. The main postoperative complications were ametropia, posterior capsule opacification(PCO), deformed pupil, pupil displacement, pigments of IOL, eccentric IOL and intraocular hypertension. The chief reasons of eyes that could not be recovered were vitreous, retina or optic nerve diseases, the key factors that caused living vision less than 0.3 were ametropia, PCO, the disease of vitreous, retina and optic nerve. Conclusions The serious complications affecting the surgery result are limited in a low range. The most important factors of the eye corrected far vision less than 0.05 are the vitreous, retina and optic nerve diseases. In order to improve the visual sight, we should add equipment to calculate the IOL diopter accurately.
7.Analysis of Myocilin gene regulatory network using a genetic genomics approach
Hong, LU ; Lu, LU ; Huai-jin, GUAN ; Hui, CHEN ; Jun-fang, ZHANG ; Nan, HU ; Jie, SHUAI
Chinese Journal of Experimental Ophthalmology 2013;31(9):851-854
Background The pathogenesis of primary open angle glaucoma(POAG) and high myopia are very complex.To construct the regulatory network of virulence genes and relevant genes that involved in pathogenicity are helpful for reveal of the pathogenesis.Objective The aim of this study was to investigate myocilin(Myoc),a gene that contributes to POAG and high myopia in eyes of BXD Recombinant Inbred(BXD RI)mice and construct the regulatory network of Myoc.Methods The affymetrix microarray system was used to detect the differential expression of Myoc in the eyes of C57BL/6J(B6),DBA/2J(D2) and BXD RI mice.Expression quantitative trait loci (eQTL) mapping was performed to construct the regulatory network of Myoc gene.Results The average expression level of the Myoc gene in the BXD strains was 10.83,and the gene exhibited expression levels ranging from 8.39 in BXD55 mice tol 1.43 in B6 mice.The eQTL mapping for the Myoc gene showed a significant likelihood ratio statistic (LRS) of 21.78.The QTL was mapped in chromosome 2,and Myoc was located on chromosome 1,indicating that the Myoc gene was a trans-acting QTL.Olfml2a was identified to be a candidate upstream gene of Myoc by analysis of bioinformatics.Genetic regulatory network analysis demonstrated that a series of genes associated with Myoc probably played roles in the pathogenesis and development of POAG and high myopia.Conclusions The genetical genomics approach provides a powerful tool for constructing pathways that contribute to complex traits,such as POAG and high myopia.
8.Association of the single nucleotide polymorphisms in the calcitonin receptor-like receptor gene with primary angle closure in a Han Chinese population
Bai, QIN ; Hai-Hong, SHI ; Rong-Rong, ZHU ; Jun-Fang, ZHANG ; Mei, YANG ; Huai-Jin, GUAN
International Eye Science 2016;16(8):1570-1572
?AIM: To study the association of the single nucleotide polymorphism ( SNP) rs1157699 in the calcitonin receptor-like receptor ( CRLR ) gene with primary angle closure ( PAC) in a Han Chinese population.?METHODS: All samples, involved 232 PAC cases and 306 controls, were obtained from an epidemiologic survey conducted in Funing, Jiangsu Province, China. Genotyping were carried out by TaqMan-MGB probe using the real time quantitative polymerase chain reaction system to study the relationship between SNP of rs1157699 in CRLR gene and PAC.?RESULTS: The prevalence of CRLRrs1157699 genotype was 67.4%, 30.0%, 2.6% for CC, CT, TT in cases, and 71.3%, 27.0%, 1.7% in controls respectively.There was no difference between the two groups in the distribution of genotype and allele frequencies of rs1157699 (P>0.05).?CONCLUSION:Our results do not support a significant role for rs1157699 in CRLR with PAC.
9.Imaging findings of primary synodal sarcoma of the lung
Yubao GUAN ; Yingying GU ; Ling CHEN ; Qingsi ZENG ; Xiaotao ZHENG ; Huai CHEN ; Chaoliang ZHANG ; Renli CEN
Chinese Journal of Radiology 2009;43(8):813-816
r diagnosing the disease to combine pathology, immunohistochemistry and SYT-SSX gene detection.
10.Parameters of quantitative multi-slice CT imaging technology in pulmonary
Huai CHEN ; Qingsi ZENG ; Yubao GUAN ; Yi GAO ; Jinping ZHENG ; Xinran HOU
Chinese Journal of Medical Imaging Technology 2010;26(2):351-354
Objective To evaluate the relevance of MSCT pulmonary function parameters and pulmonary function test (PFT) parameters, and to define the reference value of MSCT pulmonary function parameters. Methods Thirty male volunteers received clinical PFT and MSCT scan. MSCT scan was perfomed at the end of the maximum inspiratory and maximum expiratory. All data were analyzed with the lung analysis software of computer-aided inspection system correlatedly with pulmonary function parameters. Results The lung volume at full inspiratory volume (Vin) and full expiratory volume (Vex) in MSCT scan had good correlation with total lung capacity (TLC) and residual volume (RV) (r=0.90, P<0.01; r=0.74, P<0.01). Vex/Vin was correlated with RV/TLC (r=0.74, P<0.01), and Vin-Vex was correlated with MVC (r=0.85, P<0.01). In inspiration, the average lung density was (-879.51±32.82) HU, the density per unit volume was (0.12±0.03) g/cm3, while in expiratory they were (-688.14±62.38) HU and (0.31±0.06) g/cm3. Conclusion MSCT pulmonary function tests with the analysis software of computer-aided inspection system have good correlation with PFT.