1.Clinical study on triglyceride and severity of coronary arteriosclerosis stenosis in young patients
Chinese Journal of Postgraduates of Medicine 2009;32(19):13-15
Objective To evaluate the impact of triglyceride(TG) on the severity and the extent of coronary artery stenosis.Methods Ninety-three cases of young patients(below 45 years old, with or without hypertriglyeeridemia)underwent pereutaneous coronary intervention(PCI)were retrospectively analyzed.The patients were divided into three groups according to TG levels:I group(TG<1.70 mmol/L,36 cases),II group(1.70 mmol/L≤TG≤2.25 mmol/L,19 cases),III group(TG>2.25 mmol/L,38 cases).The severity of coronary artery stenosis and the extent Was compared among the three groups.Results In all patients, the male and the smoker occupied the overwhelming majority[94.62%(88/93),83.87%(78/93)].Total cholesterol(TC),non-high density lipoprotein cholesterol(HDL-C)in III group were higher than those in I group with statistical significance(P=0.006,0.003).There were no significant difference among the three groups in low density lipopmtein cholesterol(LDL-C),HDL-C,fasting blood glncose(P=0.648,0.795,0.247).There were no significant difference among the three groups in extent of coronary artery and severity of coronary artery stenosis(P=0.241,0.879).Conclusions There is no significant difference among the three groups in severity of coronary artery stenosis and extent of coronary artery.Hypertriglyeeridemia ian't the determiner on severity of coronary heart disease.
2.Nursing Care of 810 Patients Undergoing Dual-Source CT Coronary Angiography
Ying WANG ; Jian LI ; Hongliang ZHAO
Chinese Medical Equipment Journal 2003;0(10):-
Images of 812 patients undergoing dual-source CT coronary angiography were analyzed retrospectively. Effectively nursing can be improved to guarantee the quality of coronary angiography and diagnosis of diseases.
3.Validity and reliability of chinese version quality of life questionnaire for teenagers epilepsy patients
Hongliang DENG ; Xiaodong YUAN ; Jian SHEN
Chinese Journal of Behavioral Medicine and Brain Science 2012;21(2):181-183
ObjectiveTo evaluate validity,reliability and sensitivity of Chinese version quality of life in epilepsy inventory for adolescents (QOLIE-AD-48).Methods 143 cases of young epilepsy patients were tested with QOLIE-AD-48 and analyze validity,reliability and sensitivity of the scale.ResultsPolymerization/discriminant validity showed that there was correlation above 0.4 about each question within the subscale and its component table.Structural validity showed that all of the component list was significantly associated with total score (P < 0.01 ).The cronbach's α coefficient of the scale was 0.92,and 0.62 ~ 0.90 of the subscale,and ICC was 0.81.Good sensitivity was the total score decline with the increase of seriousness.ConclusionChinese version QOLIEAD-48 has good validity and reliability and sensitivity.
4.PET/CT findings of Langerhans cell histiocytosis in children
Jian ZHANG ; Suyun CHEN ; Hongliang FU ; Chao MA ; Hui WANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2016;36(4):300-303
Objective To summarize the 18F-FDG PET/CT findings of LCH in children,and explore its value in the diagnosis of LCH.Methods PET/CT imaging and clinical data of 13 patients (6 males,7 females;average age (3.0±2.3) years) with LCH confirmed by histology before treatment from August 2011 to December 2015 in Xin Hua Hospital were retrospectively analyzed.Results All 13 patients have different degrees of bone destruction with increased metabolism,the common lesion sites were craniofacial bone,spine,limb long bones,ribs/chest/shoulder blade and pelvic bone.Lymph node lesions which manifested lymph node enlargement with increased metabolism were found in 10 cases,and the SUVmax was 4.0±1.3.Diffuse FDG uptake in spleen was found in 10 cases.There were 4 cases with liver lesions,3 with lung lesions,1 with high metabolic nodules in muscle,1 with orbital lesions and 1 with intraspinal high metabolic nodules.Conclusion 18F-FDG PET/CT could display the distribution and activity of LCH,and plays an important role in the diagnosis and systemic evaluation of LCH.
5.Clinical analysis of 29 cases of cervical necrotizing fasciitis.
Yaming ZHAO ; Hongliang YI ; Jian GUAN ; Yujun ZHANG ; Shankai YIN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2014;28(7):490-492
OBJECTIVE:
To study the experience of clinical features and treatment of deep cervical necrotizing fasciitis.
METHOD:
All 29 cases of cervical necrotizing fasciitis patients were diagnosed by CT, 12 cases underwent tracheostomies, lateral neck incisions and drainage operations, the other 17 patients underwent lateral neck incisions and drainage operations. Sequently washing, dressing changes and anti infection treatments were taken.
RESULT:
Twenty-eight cases were cured, 1 cases died. During a follow-up of half a year,no relapse.
CONCLUSION
When patient was sufferd the cervical necrotizing fasciitis, surgical operation for exploration should be taken as soon as possible,and incision and drainage in the treatment of cervical abscess would obtain a satisfactory curative effect, which would prevent serious complications.
Adult
;
Aged
;
Fasciitis, Necrotizing
;
diagnosis
;
surgery
;
Female
;
Humans
;
Male
;
Middle Aged
;
Neck
6.The clinical application of low-dose dual-source whole-body angiography CT in Takayasu’s arteritis
Yanmeng DENG ; Jian LI ; Hongliang ZHAO ; Minwen ZHENG
Journal of Practical Radiology 2016;32(3):406-410
Objective To evaluate the low-dose dual-source whole-body CT angiography in assessing the arteries of Takayasu’s arteritis (TA).Methods Low-dose whole-body CT angiography(CTA)was performed in 57 consecutive patients with suspected TA. The scanning parameters were performed with tube voltage 80 kV and attenuation-based tube current modulation with a referenced tube current at 300 mAs.The volume CT dose index (CTDIvol)and dose-length product (DLP)were obtained for all scans.Subjec-tive and objective image quality of different arteries were assessed in seven anatomic territories,including intracranial,cervical,tho-racic,abdominal,upper extremity,thigh and shank.In addition,CT findings of whole-body arteries were recorded.Results Forty out of fifty-seven patients with definite diagnosis of TA enrolled in this study.Mean CTDIvol and DLP for all patients were (2.5± 0.9)mGy and (403.7±91.4)mGy·cm,respectively.The scoring order of subjective and objective iamge quality was neck,chest, abdomen,thigh,upper extremity,head and shank.5.9% of intracranial arteries,3.3% of lower extremity arteries and 0.5% of upper extremity arteries were extra detected.Conclusion The extra CT findings of intracranial,lower extremity and upper extremity arter-ies provides a more comprehensive evaluation of whole-body arteries involvement.
7.Channel radiofrequency volumetric reduction of tongue base a vitro porcine three-dimensional reconstruction experiment for the treatment of obstructive sleep apnea hypopnea syndrome
Jian GUAN ; Hongliang YI ; Dongzhen YU ; Yanyan HUANG ; Shankai YIN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2009;(15):700-702,705
Objective:To investigate lesion size caused by channel radiofrequency volumetric reduction of por-cine tongue base in vitro using the technique of three-dimensional reconstruction. And to evaluate safety about channel radiofrequency volumetric reduction of tongue base. Method: Eighteen fresh porcine tongues were randomly separated into six groups,and each group had three ones. The tongue bases were designed six points according to description of Powell. Tongues base were acted on 10 s and 6 level by Coblation radiofrequency system and were cut into serial freezing histological sections. These segments were sectioned at 20 μm on the injury lesion and stained with H & E. Collected 2D digital imagine of order histological sections, drawn and cut apart part of the le-sion of these sections. Images were procesed IPS and were taken three-dimensional reconstruction and statistics an-alyzes with SPSS10. 0. Result: The mean value of tongue base lesion volumes among points was (359. 5± 5. 6)mm~3 ,(364. 3±7. 0)mm~3 ,(363. 7±7. 2)mm~3, (354. 1±11. 8)mm~3, (349. 4±17. 2)mm~3 ,(353. 5±7. 9)mm~3 separately. Statistic analysis by one-way ANOVA showed that there was a insignificant difference between the groups(P>0. 05). Conclusion:These results demonstrated no significant effect lesion size in channel radiofrequency volumetric reduction in the different points of the tongue base. These data also indicated that coblation radiofre-quency system is a safe method for obstructive sleep apnea hypopnea syndrome.
8.Preoperational application of dual-source CT in assessment of three branches aortic arch covered stent graft implantation(preoperational evaluation for DeBakey type Ⅰ aortic dissection)
Hongliang ZHAO ; Yi HUAN ; Minwen ZHENG ; Jian LI
Journal of Practical Radiology 2015;(6):982-984,993
Objective To estimate the application value of dual-source CT on preoperational evaluating new type of three branches aortic arch covered stent graft implantation on DeBakey type I aortic dissection.Methods 20 cases with DeBakey type I aortic dissec-tion prepared to performe three branches aortic arch covered stent graft implantation were reviewed,and their CT findings were ana-lyzed in order to evaluate the guiding value for operation.Results The location and size of entries were determined and the diameter of aortic arch and three branchesas well as the intervals of three branches were also measured by dual-source CT.Furthermore, blood-supply for main vessel and complications related with covered stent were further analyzed prior to operation.The surgical pro-tocols were designed according to preoperational CT findings.Among all cases,13 cases were fit for new type of three branches aor-tic arch covered stent graft implantation.While the rest cases (N=7)were adopted other operations due to non-fitted indications. Conclusion Dual-source CT is of significance for preoperational evaluating new type of three branches aortic arch covered stent graft implantation on DeBakey type I aortic dissection.
9.Composition Changes of Aurantii Fructus before and after Fermentation Processing and Its Technology Op-timization
Dongjian ZHANG ; Wei LI ; Zhitao LIANG ; Hongliang JIAN ; Chuanqi HUANG ; Junheng HE
China Pharmacy 2017;28(7):971-974
OBJECTIVE:To compare the composition changes of Aurantii fructus before and after fermentation processing and optimize its fermentation processing technology. METHODS:UPLC was conducted to compare the raw and fermentation processed products of same batch of Aurantii fructus,and ensure the chromatographic peaks after fermentation processing. Using peak areas of 4 chromatographic peaks and mildew characteristics of samples as index,fermentation temperature,humidity and time as factor, L9(34)orthogonal test was designed to optimize the fermentation processing technology,and verified it. RESULTS:After fermenta-tion processing,Aurantii fructus obviously showed 2 new monosaccharide glycosides components;the optimized fermentation tech-nology was as follows as fermentation temperature of 30 ℃,humidity of 70% and time of 7 d;verification test results showed RSD of each indicator of decoction pieces prepared by optimized fermentation technology in 3 tests were lower than 2.0%(n=3). CONCLUSIONS:Fermentation processing may lead obvious chemical composition changes in Aurantii fructus;the optimized fer-mentation processing technology can increase the contents of characteristic peaks.
10.Dual-Source Computed Tomographic Coronary Angiography:Image Quality and Stenosis Diagnosis of Patients with High Heart Rates
Minwen ZHENG ; Xiaoying WANG ; Mingguo SHI ; Hongliang ZHAO ; Jian LI ; Yi HUAN
Chinese Medical Equipment Journal 1989;0(01):-
Objective To prospectively evaluate the effects of heart rate and heart-rate variability on dual-source computed tomographic coronary image quality in patients with high heart rates,and to determine retrospectively the accuracy of dualsource computed tomographic diagnosis of coronary artery stenosis in the same patients.Methods The image quality and diagnostic accuracy were compared between the normal group of 40 patients whose heart rates exceeded 70 beats/min and the control group of 40 patients whose heart rates were 70 beats/min or slower.Results No statistically significant differences between the groups were found in diagnostic-image quality scores of total segments or of any coronary artery,nor were any significant differences found between the groups in the accurate diagnosis of angiographically significant stenosis.Calcification was the chief factor that affected diagnostic accuracy.In high -heart -rate patients,heart -rate variability was significantly related to the diagnostic image quality of all segments(P=0.001) and of the left circumflex coronary artery(P=0.016).Heart-rate variability more than 5 beats/min most strongly contributed to an inability to evaluate segments in both groups.When heart rates rose,the optimal reconstruction window shifted from diastole to systole.Conclusion The image quality of dual -source computed tomographic coronary angiography at high heart rates enables sufficient diagnosis of stenosis,although variability of heart rates significantly deteriorates image quality.