1.Effects of P2X4 receptor in spinal microglia on rrTNF-induced pathologi-cal pain
Qingjuan GONG ; Honghua WANG ; Ying LIANG ; Zhenhe LU ; Jinsheng CHEN ; Qiaodong HUANG ; Yu YUE
Chinese Journal of Pathophysiology 2015;(5):834-838
AIM:To investigate the effects of P2X4 receptor on peri-sciatic administration of recombinant rat TNF-α(rrTNF)-induced mechanical allodynia.METHODS:Male Sprague-Dawley rats (180~200 g) were used in the experiments.The levels of P2X4 receptor on day 3, day 7 and day 14 after peri-sciatic administration of rrTNF were exam-ined by Western blot, and the location of P2X4 receptor in the spinal dorsal horn was observed by double immunofluores-cence staining.The changes of 50%paw-withdrawal thresholds of the rat were detected by behavioral test, and the level of TNF-αin the spinal dorsal horn was also examined by Western blot when TNP-ATP was intrathecally injected before the ad-ministration of rrTNF.RESULTS:Compared with control group, the expression of P2X4 receptor in the spinal dorsal horn on the ipsilateral side significantly increased on day 3, day 7 and day 14 (P<0.01) after rrTNF (100 ng/L) administra-tion.P2X4 receptor was co-localized only with microglia, but not with neurons or astrocytes.Intrathecal injection of TNP-ATP before rrTNF administration prevented mechanical allodynia induced by rrTNF and inhibited the upregulation of TNF-αin the spinal dorsal horn.CONCLUSION:P2X4 receptors in microglia may be involved in rrTNF-induced mechanical allodynia by the upregulation of TNF-αin the spinal dorsal horn.
2.Aerodynamic Measure of the Phonation in Patients with Vocal Polyps and Vocal Nodules
Yue MI ; Peng LIN ; Jianqun DU ; Honghua NU ; Jiamei OHEN ; Jing BI
Journal of Audiology and Speech Pathology 2010;18(2):138-140
Objective To investigate the aerodynamic characteristics of vocal polyps and vocal nodules.Methods Aerodynamic parameters of 58 patients with vocal polyps or vocal nodules and 30 normal adults were measured by Aerophone Ⅱ Voice Function Analyzer.The mean airflow rate,intraoral pressure,glottal resistance,glottal efficiency were compared among different group.Results The mean airflow rate,glottal resistance and glottal efficiency of vocal polyps,vocal nodules and normal adult were 254.50±36.02 ml/s,33.55±4.63 cmH_2O/(L·S),2.46±1.49,177.45±25.93 ml/s,38.83±8.88 cmH_2O/(L·S),7.75±3.71,118.44±29.98 ml/s,53.04±8.64 cmH_2O/(L·S),9.17±3.87,respectively.The difference between them was significant(P<0.01).The difference of intraoral pressure between vocal polyps (8.97±1.36 cmH_2O) and normal adult (6.24±0.99 cmH_2O) was significant (P<0.01).The mean airflow rate,glottal resistance,glottal efficiency were significantly different between vocal polyps and vocal nodules(P<0.01).Conclusion The degree of vocal fold adduct and the effciency of voice production in vocal polyps is worse than that of vocal nodules.The aerodynamic parameters can make quantifiable,objective assessment in voice function of vocal polyps and vocal nodules.
3.Acute pericardial tamponade following superior vena cava stent migration in a dialysis patient: A case report
Bo ZHENG ; Honghua YUE ; Tailong ZHANG ; Weitao LIANG ; Zhong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2021;28(10):1258-1260
Central venous stenosis is a common complication following long-term dialysis catheter placement in dialysis patients. Generally, percutaneous angioplasty is the treatment of choice, and venous stent implantation should be considered in different situations. However, the venous stent migrating into right atrium is a rare but fatal complication. We presented a patient whose superior vena cava stents migrated into right atrium, resulting in acute tamponade, and exploratory thoracotomy was proceeded.
4.The effect of COVID-19 vaccine on international normalized ratio value of patients after cardiac mechanical valve replacement: A cross-sectional investigation
Kang HE ; Longrong BIAN ; Honghua YUE ; Weitao LIANG ; Zhong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(09):1100-1104
Objective To investigate the vaccination rate of Coronavirus Disease 2019 (COVID-19) vaccine in patients undergoing cardiac mechanical valve replacement and to evaluate its effect on international normalized ratio (INR) value. Methods We investigated 132 patients who had received cardiac mechanical valve replacement and followed up in the Department of Cardiovascular Surgery, West China Hospital of Sichuan University from May to October 2021. There were 51 males and 81 females aged 26-72 (53.01±9.51) years. Results The vaccination coverage rate was 53.8%. Among the 61 unvaccinated patients, concerns about heart side-effects were the main reason. The average INR of the first review after vaccination was higher than that of the last review before vaccination, with a difference of 0.40±0.72 (P<0.001). Conclusion The vaccination rate of patients after cardiac mechanical valve replacement is low. At the same time, COVID-19 vaccine may increase INR value, and it is suggested that patients should increase the frequency of review and adjust warfarin dosage after vaccination.