1.Syk and VEGF-C in breast cancer's expression with lymph node metastasis
Chinese Journal of Immunology 2014;(5):681-683
Objective:To explore the relationship of Syk and VEGF-C expression in breast cancer with lymph node metastasis . Methods:The expression of Syk and VEGF-C in 40 cases of breast cancer were determined using immunohistochemistry assay .Then, the positive rates of Syk and VEGF-C were compared with lymph node metastasis .Results:The expression rate of VEGF-C and Syk in breast cancer was respectively 77.5%(31/40), 37.5%(15/40).VEGF-C protein expression was not significant related with the tumor diameter (P>0.05) and histological grade (P>0.05), but was significantly associated with lymph node metastasis (P<0.05).Syk protein expression was not significant related with tumor diameter (P>0.05) and the histological grade(P>0.05), and was associated with lymph node metastasis (P<0.05).The difference of Syk and VEGF-C had statistics significance(P<0.05).Con-clusion:Syk and VEGF-C involved in the lymphatic invasion and metastasis , may be an important indicator of prognosis .
2.Senescence is a defensive mechasim against oncogene-induced tumorigenesis
Basic & Clinical Medicine 2006;0(05):-
Cellular senescence is a permanent cell cycle arrest that may prevent the aged or abnormal cells from further expansion and is therefore a safeguard mechanism against unlimited cell proliferation.Recent studies demonstrated that oncogene-induced senescence could prevent neoplastic transformation in vitro and in vivo,and oncogene might cause tumors only in senescence deficient cells.Although the mechanism of the cellular senescence has not been completely illustrated,activation of P16INK4a-RB and ARF-P53 pathways has been implicated in this process.Further investigation of the signaling pathways leading to senescence may offer new avenues for tumor treatment.
3.Dual effects of rapamycin on immuno-suppression and tumor inhibition
Basic & Clinical Medicine 2006;0(12):-
Rapamycin is frequently used as an immunosuppressive agent and also plays an important role in tumor suppression.It combines to FKBP12 and forms a compound to inhibit the serine/threonine protein kinase mammalian target of rapamycin(mTOR),its activation is required for protein synthesis and cell-cycle progression.Rapamycin can block cell cycle at G1 phase and to inhibit cell proliferation.Furthermore rapamycin may inhibit cytokine production and cytokine signaling.Therefore rapamycin is used in the treatment of post-transplantation organ rejection and tumor therapy due to its dual effects of immuno-suppression and tumor inhibition.
4.Demographic Structure, Environmental Quality and Resident Health Expenditures: Based on the Persoective of Spatial Econometrics
Hongbing OUYANG ; Zhinan ZHANG
Chinese Health Economics 2017;36(8):58-60
Objective:To analyze the impacts of sustainable deterioration of environment quality and demographic structure adjustment on urban residents' health expenditure.Methods:Non-spatial panel model and spatial panel model were applied to use inter-provincial panel data to conduct the empirical analysis.Results:Environment quality,demographic age structure and interaction had significant impact on urban residents' health expenditure.Conclusion:Demographic structure transformation and environment quality deterioration were the two difficulties faced by China's medical and health system.The construction and reform of medical and health system should focus on these challenges.
5.Establishment of medical equipment safety risk management system
Huawei ZHANG ; Lijia ZHANG ; Hongbing JIANG
China Medical Equipment 2016;13(1):32-34
Objective:To explore the establishment of medical equipment safety risk management system new pathways.Methods: By studying the Medical Device Clinical use of safety management practices (Trial) and the three general hospital accreditation standards Implementing Rules (2011 Edition) Chapter VI (hospital management) Article 9 (Medical Equipment Management) accreditation standards.Results: Risk control made in accordance with relevant national policies and related evaluation criteria four off management model, and to establish an effective risk management system of medical equipment safety.Conclusion: The establishment of medical equipment safety risk management system helped to ensure medical quality and safety, to provide reference for the clinical use of medical equipment to explore the system security risk management through.
6.Effect of estrogen on the permeability of retinal blood vessel
Hongbing ZHANG ; Junjun ZHANG ; Lin MA
Chinese Journal of Ocular Fundus Diseases 2001;0(03):-
Objective To explore the effect of estrogen on the permeability of retinal blood vessel by ovariectomy. Methods Twenty-two healthy rats were divided into experimental and control group randomly. Estrogen level of rats decreased due to ovariectomy in the experimental group while stabilized by sham-ovariectomy in the control group. The results were confirmed by vaginal epithelium smearing. Retinal vein occlusion was established by photodynamic method, and leakage of Evan's blue in retina was determined by spectrophotometer. Results Mature value of vaginal epithelium decreased significantly in ovariectomy rats( t=21.008,P =0.000) while not significantly in sham-ovariectomy ones ( t=0.319,P =0.756); the mean leakage of Evans blue was (25.503 0?4.378 47) ng/mg in experimental group, and (17.830 0?4.265 69) ng/mg in the control group, and the difference between the two groups is significant( t=3.969 36,P =0.001). Conclusion Ovariectomy is an useful method to study the effect of estrogen on ocular diseases, and when estrogen level decreases, the permeability of retinal blood vessel increases.
7.Study on Relationship between the Main Symptoms Distribution and Different Factors of 360 Cases of IBS-D
Hongbing WANG ; Shengsheng ZHANG ; Zhenhua LI
Chinese Journal of Information on Traditional Chinese Medicine 2006;0(03):-
Objective To study the epidemiological characteristics of diarrhea-predominant irritable bowel syndrome (IBS-D) as well as the relationship between the main syndromes and different factors. Method The relevant information of patients were collected by clinical epidemiological method and the relationship between the main characteristics of the IBS-D syndromes and different factors was explored with the major syndromes as the key link. Result Most of the cases aged 30~49 years old. Special hobbies of patients followed by drinking, smoking, addicting spicy, addicting coffee and so on. Poor emotion, mental stress and diet were the main inducements. Liver stagnation and spleen deficiency has the highest percentage (44.7%). The distribution of syndromes in different ages, different genders, different occupations and different education had no significant difference. Conclusion The number of IBS-D hospital visiting-patients is lower than the actual number of illness people. Mental factors are important internal factors, and dietary factors may be an important external factor. Different factors have no effect on the distribution of syndromes.
8.Comparison of clinical value of two kinds of imunoassay method in the detection of related antibody of patients with HCV
Yueqin SONG ; Hongbing ZHANG ; Xuelian LI
Chinese Journal of Primary Medicine and Pharmacy 2017;24(9):1416-1419
Objective To compare the clinical value of two kinds of imunoassay method including CLIA and ELISA in the detection of related antibody of patients with HCV.Methods 60 patients with HCV were chosen as study subjects,and the related antibodies of patients were detected by CLIA and ELISA.The positive rates of anti HCV antibody,anti-3E antibody,anti-GP210 antibody,anti-SP100 antibody,anti-PML antibody and anti-AMA -M2 antibody detected by CLIA and ELISA were compared.Results The positive rates of anti-HCV antibody detected by CLIA and ELISA were 83.33% (50/60),98.33% (59/60),respectively.The anti-HCV antibody detected by CLIA was significantly higher than by ELISA (x2 =4.73,P =0.03).The positive rates of anti-3E antibody,anti-GP210 antibody,anti-SP100 antibody,anti-PML antibody and anti-AMA-M2 antibody detected by ELISA were 11.67 % (7/60),6.67 % (4/60),11.67 % (7/60),10.00 % (6/60),11.67 % (7/60),respectively,those detected by CLIA were 73.33 % (44/60),50.00% (30/60),38.33 % (23/60),58.33 % (35/60),80.00%(48/60),respectively.The positive rates of anti-3E antibody,anti-GP210 antibody,anti-SP1O0 antibody,anti PML antibody and anti-AMA-M2 antibody detected by CLIA were significantly higher than by ELISA(x2 =18.81,11.51,13.23,15.08,13.75,all P<0.05).Concelusion Compared with ELISA,CLIA in the detection of related antibodies of patients with HCV can efficiently higher the positive rate of anti-HCV and autoantibody.
9.The observation on apoptosis from vitrectomy specimens of proliferative vitreoretinopathy
Hua YANG ; Hongbing GUAN ; Xi ZHANG
Chinese Journal of Ocular Fundus Diseases 1999;0(02):-
urpose To investigate apoptosis in vitrectomy specimens of proliferative vitreoretinopathy. Methods Vitrectomy specimens from 60 cases of different classes of proliferative vitreoretinopathy were studied by TdTmediated dUTP nick end labelling(TUNEL)method. Results The characteristic change of apoptosis was observed in all vitrectomy specimens.The amount of apoptotic nonpigmentary cell is gradually decreasing along with the development of proliferative vitreoretinopathy,and apoptotic pigmentary cells are observed. Conclusion There are different kinds of apoptosis cell in vitrectomy specimens of proliferative vitreoretinopathy.It is suggested that apoptosis might be one of the important mechanisms of regulating the degree in proliferative vitreoretinopathy.
10.A new detection and analysis of flow rate accuracy on a new tracetype micro-injection drug ;pump and syringe pump flow rate accuracy
Huawei ZHANG ; Zhenglu BAI ; Hongbing JIANG
China Medical Equipment 2016;13(7):31-33,34
Objective:is toTo detect a new type of micro-injection pump, its flow rate of quality control testing and syringe pump through the comparative analysis, and study its accuracy and stability. Methods:A certain brand of injection flow rate accuracy and stability of drug pumps and syringe pumps were detected by the use of professional Fluke infusion device analyzer and a dedicated infusion line. Results:Compared the injection pump with syringe pump flow rate of errors, a flow rate was 1 ml/h, t. The errordeviation range of micro-injection pump flow rate is larger than the syringe pump, and a flow rate was 25 ml/h and 50 ml/h, both the same, . Wwith drug detection time went on, a flow rate of injection pump has tended to stabilize. After the flow rate is stable, the longer the detection time is, the overall error is smaller. At the time of 15 min, test data are in line with national testing standards. Conclusion:The combination of injection pump and infusion pump, the micro-injection pump can meet the growing demand for clinical departments, and its stability and accuracy can meet the national standards.