1.Senescence is a defensive mechasim against oncogene-induced tumorigenesis
Basic & Clinical Medicine 2006;0(05):-
Cellular senescence is a permanent cell cycle arrest that may prevent the aged or abnormal cells from further expansion and is therefore a safeguard mechanism against unlimited cell proliferation.Recent studies demonstrated that oncogene-induced senescence could prevent neoplastic transformation in vitro and in vivo,and oncogene might cause tumors only in senescence deficient cells.Although the mechanism of the cellular senescence has not been completely illustrated,activation of P16INK4a-RB and ARF-P53 pathways has been implicated in this process.Further investigation of the signaling pathways leading to senescence may offer new avenues for tumor treatment.
2.Dual effects of rapamycin on immuno-suppression and tumor inhibition
Basic & Clinical Medicine 2006;0(12):-
Rapamycin is frequently used as an immunosuppressive agent and also plays an important role in tumor suppression.It combines to FKBP12 and forms a compound to inhibit the serine/threonine protein kinase mammalian target of rapamycin(mTOR),its activation is required for protein synthesis and cell-cycle progression.Rapamycin can block cell cycle at G1 phase and to inhibit cell proliferation.Furthermore rapamycin may inhibit cytokine production and cytokine signaling.Therefore rapamycin is used in the treatment of post-transplantation organ rejection and tumor therapy due to its dual effects of immuno-suppression and tumor inhibition.
3.Demographic Structure, Environmental Quality and Resident Health Expenditures: Based on the Persoective of Spatial Econometrics
Hongbing OUYANG ; Zhinan ZHANG
Chinese Health Economics 2017;36(8):58-60
Objective:To analyze the impacts of sustainable deterioration of environment quality and demographic structure adjustment on urban residents' health expenditure.Methods:Non-spatial panel model and spatial panel model were applied to use inter-provincial panel data to conduct the empirical analysis.Results:Environment quality,demographic age structure and interaction had significant impact on urban residents' health expenditure.Conclusion:Demographic structure transformation and environment quality deterioration were the two difficulties faced by China's medical and health system.The construction and reform of medical and health system should focus on these challenges.
4.Syk and VEGF-C in breast cancer's expression with lymph node metastasis
Chinese Journal of Immunology 2014;(5):681-683
Objective:To explore the relationship of Syk and VEGF-C expression in breast cancer with lymph node metastasis . Methods:The expression of Syk and VEGF-C in 40 cases of breast cancer were determined using immunohistochemistry assay .Then, the positive rates of Syk and VEGF-C were compared with lymph node metastasis .Results:The expression rate of VEGF-C and Syk in breast cancer was respectively 77.5%(31/40), 37.5%(15/40).VEGF-C protein expression was not significant related with the tumor diameter (P>0.05) and histological grade (P>0.05), but was significantly associated with lymph node metastasis (P<0.05).Syk protein expression was not significant related with tumor diameter (P>0.05) and the histological grade(P>0.05), and was associated with lymph node metastasis (P<0.05).The difference of Syk and VEGF-C had statistics significance(P<0.05).Con-clusion:Syk and VEGF-C involved in the lymphatic invasion and metastasis , may be an important indicator of prognosis .
5.Establishment of medical equipment safety risk management system
Huawei ZHANG ; Lijia ZHANG ; Hongbing JIANG
China Medical Equipment 2016;13(1):32-34
Objective:To explore the establishment of medical equipment safety risk management system new pathways.Methods: By studying the Medical Device Clinical use of safety management practices (Trial) and the three general hospital accreditation standards Implementing Rules (2011 Edition) Chapter VI (hospital management) Article 9 (Medical Equipment Management) accreditation standards.Results: Risk control made in accordance with relevant national policies and related evaluation criteria four off management model, and to establish an effective risk management system of medical equipment safety.Conclusion: The establishment of medical equipment safety risk management system helped to ensure medical quality and safety, to provide reference for the clinical use of medical equipment to explore the system security risk management through.
6.Effect of estrogen on the permeability of retinal blood vessel
Hongbing ZHANG ; Junjun ZHANG ; Lin MA
Chinese Journal of Ocular Fundus Diseases 2001;0(03):-
Objective To explore the effect of estrogen on the permeability of retinal blood vessel by ovariectomy. Methods Twenty-two healthy rats were divided into experimental and control group randomly. Estrogen level of rats decreased due to ovariectomy in the experimental group while stabilized by sham-ovariectomy in the control group. The results were confirmed by vaginal epithelium smearing. Retinal vein occlusion was established by photodynamic method, and leakage of Evan's blue in retina was determined by spectrophotometer. Results Mature value of vaginal epithelium decreased significantly in ovariectomy rats( t=21.008,P =0.000) while not significantly in sham-ovariectomy ones ( t=0.319,P =0.756); the mean leakage of Evans blue was (25.503 0?4.378 47) ng/mg in experimental group, and (17.830 0?4.265 69) ng/mg in the control group, and the difference between the two groups is significant( t=3.969 36,P =0.001). Conclusion Ovariectomy is an useful method to study the effect of estrogen on ocular diseases, and when estrogen level decreases, the permeability of retinal blood vessel increases.
7.Analysis on hospital medical equipment electrical safety testing
Huawei ZHANG ; Hang QIN ; Hongbing JIANG
China Medical Equipment 2015;(7):25-26,27
Objective:To study the electrical safety of multi-parameter monitor and defibrillation monitor, and guarantee the safe and effective operation by through the medical equipment electrical safety performance in our hospital.Methods: To test 101 different models of multi-parameter monitor and defibrillation monitor electrical safety.Results: The one-time pass rate of 96%, and the two-time rate was 98%, also one multi-parameter monitor and defibrillation monitor hadn’t meet electrical safety performance after repairing.Conclusion: The equipments that don’t meet electrical safety performance prohibit using for clinical purposes; To ensure the safety of medical equipment and life safety of medical workers and patients by through developing the testing of the medical equipment electrical safety performance in our hospital.
8.Sensitivity and specificity of identification of the infarct-related artery by electrocardiogram
Xiaojiang ZHANG ; Hongbing YAN ; Yuannan KE
Chinese Journal of Interventional Cardiology 2003;0(05):-
Objective To evaluate the sensitivity,specificity and accuracy of the algorithm for electrocardiographic identification of the IRA and exact site of occlusion of the IRA.Methods According to the algorithm for electrocardiographic identification,we predicted the IRA by analyzing ECG in 896 patients with ST-segment elevation myocardial infarction(STEMI),who were enrolled in this study and underwent primary coronary angiography.Results The results indicated that left main coronary disease showed a sensitivity of 100%,specificity of 99% and accuracy of 99%;and at the same time the left anterior descending artery(LAD) with 99%,99% and 99%(proximal LAD: 84%,90% and 88%;middle and distal LAD: 57%,94% and 88%);the left circumflex artery with 64%,95% and 91%;the right coronary artery(RCA):89%,92% and 91%(proximal RCA: 51%,96% and 88%;middle and distal RCA: 68%,92% and 85%) respectively.Conclusion This study suggests that electrocardiogram is a crucial tool in the identification of the IRA in left main coronary,LAD and proximal RCA with predicting exact site of culprit lesion.The LCX or middle and distal RCA can be difficult to discriminate.
9.Closure of femoral artery puncture site after CAG or PCI with the Angio-seal
Hongbing XIAO ; Dadong ZHANG ; Yueguang CHEN
Chinese Journal of Interventional Cardiology 2003;0(06):-
Objective To estimate the value of the Angio seal (Vascular Cloure Device, St Jude Medical) in femoral artery closure after CAG (coronary angiography) or PCI (percutaneous coronary intervention). Methods From Oct 2002 to Oct 2003 316 patients received CAG or PCI at our hospital They were divided into group A (150 patients) and group B (166 patients) The Angio seal was useded in group A to close the puncturing spot of femoral artery, and the side of the body punctured was trigged for 4 hours Common hemostasis was adopted in group B Results As compared with group B, time to hemostasis and time to ambulation were notably decreased and groin hematoma and time to bleeding disposed at the puncture site were markedly reduced in group A Conclusion Safe and effective, the Angio seal may be widely adopted in clinical practice
10.Effects of tongxinluo on C-reactive protein and clinical prognosis in patients after coronary stenting
Hongbing XIAO ; Dadong ZHANG ; Jun GU
Journal of Interventional Radiology 2006;0(08):-
Objective To investigate the effects of Tongxinluo on C reactive protein(CRP)and clinical prognosis in patients after coronary stenting. Methods From January 2003 to December 2004, 132 patients in our department diagnosed as coronary artery disease(including acute myocardial infarction, unstable angina pectoris and stable angina pectoris)were divided into two groups: Tongxinluo group and control group. The control group received routine treatment, while Tongxinluo group based on routine treatment was administrated with Tongxinluo capsule in combination for 6 months. Results CRP level was much lower in Tongxinluo group together with apparent decrease of the major adverse cardiac event(MACE)rate in 6 months' follow-up than those of the control group, but showing no difference in coronary arterial restenosis between the two groups at 6 months after coronary stenting. Conclusion Tongxinluo has favorable effects to decrease the CRP level and improve clinical efficiency together with prognosis for patients after coronary stenting.