1.The development of recombinant factor Ⅷ concentrates for clinical application
International Journal of Pediatrics 2011;38(6):548-550
Replacement therapy with plasma derived or recombinant F Ⅷ (rFⅧ) concentrates is only effective way to treat hemophilia A.Currently,the first,second and third generation rFⅧ are commercially available.Of the three products,the third generation rFⅧ products are best,because of no additional human or animal plasma proteins at any period.The use of rFⅧ concentrates has greatly improved the safety of replacement therapy in hemophilia A and reduced the risk of blood-borne pathogen transmission.In this article we review the current knowledge about the three rF Ⅷ concentrates,analyzing their main characteristic and their clinical hemostatic efficacy and safety.
3.Evaluation of short-term visual quality following implantation of unsteady aberration aspheric intraocular lens
Hong-hui, LI ; Juan, ZHAO ; Li-hong, WANG
Chinese Journal of Experimental Ophthalmology 2013;(4):365-371
Background Cataract surgery with replacement of the natural lens with an artificial intraocular lens(IOL) has developed into refractive surgery.Visual acuity is not the only evaluation criterion,but more focus has been put into the visual quality postoperatively.Aspherical IOL could improve the visual quality by decreasing the aspherical aberration.Objective This study was to investigate the short-term visual acuity,aberration alteration and clinical application of unsteady aberration aspheric IOL.Methods A retrospective case-controlled study was designed.Forty-two eyes of 30 patients with age-related cataract were included and divided into two groups.Phacoemulsification combined with unsteady aberration aspheric IOL implantation was performed in 21 cataractous eyes of the ZO group,and phacoemulsification combined with spherical IOL implantation in the other 21 eyes of the ADAPT group.Visual acuity,best corrected visual acuity (BCVA),contrast visual acuity,spherical aberration of the whole eye,contrast sensitivity (CS),dare sensitivity,modulation transfer function (MTF) and apparent accommodation were measured three months after surgery.All the parameters were compared between the two groups.The correlation of CS with the root mean square of spherical aberration,root mean square of comatic aberration and age was analyzed by multiple linear regression analysis.Written informed consent was obtained from each patient prior to operation.Results No significant differences were found in unconnected visual acuity,BCVA and spherical degrees between the ZO group and ADAPT group 3 months after surgery(P>0.05).The CS value in the ZO group was significantly higher than that of the ADAPT group under scotopic background condition with spatial frequencies of 6,12,18 cpd,low glare the spatial frequencies of 6,12 cpd,as well as high glare with 12,18 cpd(P<0.05).Under a scotopic background with 100% contrast or a photopic background with 5% contrast,the contrast visual acuity of the ZO group was significantly higher than that of the ADAPT group (t =20.217,P =0.000 ; t =4.568,P =0.039).At pupil diameters of 3,4 and 5 mm,the Z4 value was significantly lower in the patients of the ZO group than that of the ADAPT group (U =63.000,P =0.000 ; U =52.000,P =0.000 ; U =36.000,P =0.000).However,no significant differences were seen in the Trefoil aberration (Z6)value at 3 mm and 4 mm of pupil diameter(U =204.000,P =0.678;U =215.000,P =0.890) and coma aberration (Z7,Z8) value at 3,4 and 5 mm of pupil diameter between ZO group and ADAPT group(Z7:U=156.000,P =0.159 ; U =196.000,P =0.538 ; U =199.000,P =0.587 ; Z8:U=163.000,P =0.148 ;U=214.000,P =0.870;U =143.000,P =0.061).When the pupil diameter was 5 mm,Z6 value was significantly lower in the patients of the ZO group than that of the ADAPT group (U =4.000,P =0.000).The higher-order aberration MTF was significantly elevated in the ZO group compared with the ADAPT group from 5 through 20 cpd at a pupil diameter of 4 mm (P<0.05) and 10,20,25,30 cpd at a pupil diameter of 5 mm (P<0.05).A slightly lower objective accommodation was found in the ZO group compared with the ADAPT group without statistically significant difference(t =0.003,P>0.05).Multiple linear regression analysis showed that the change in CS was associated with the root mean square of the spherical aberration and IOL type(β=0.544,R2=0.519,P =0.000)rather than with the root mean square of the comatic aberration and age.Conclusions The postoperative visual quality in the unsteady aberration aspheric IOL implanted eye is superior to that in the spherical IOL implanted eye due to a reduction in spherical aberration.
4.Clinical Observation on Comprehensive Treatment of 80 Cases of Chronic Type Ⅲ Prostatitis by Elongated Needle, Microwave and Moritatherapy
Hui LI ; Hong ZHANG ; Jianqiang GE
Journal of Acupuncture and Tuina Science 2005;3(6):8-10
After 160 cases of chronic type Ⅲ prostatitis were divided into the treatment group (n= 80) and control group (n = 80), in the treatment group, first Zhibian (BL 54) was punctured toward Shuidao (ST 28) and then Qihai (CV 6), Guanyuan (CV 4), Shuidao (ST 28)Baihui (GV 20), Fengchi (GB 20), Sishencong (Ex-HN 1), Sanyinjiao (SP 6) and Taichong (LR 3) were punctured, and at the same time, digital computerized microwave apparatus was inserted into the anus for microwave treatment. Afterward, moritatherapy was applied for psychological consultation for the patients. In the control group, compound sinomin and Phenoxybenzamine Hydrochloride Tablets were used orally. The results showed that the therapeutic effects were respectively 92.5% and 68.8% in two groups, with statistic significance (P < 0.01).
5.Study on Early Changes of Myocardial Combination Enzyme in Dogs with Gunshot Wound in Seawater.
Hui MENG ; Hong SHEN ; Naibin LI
Journal of Medical Research 2006;0(10):-
Objective To investigate the changes of myocardial combination enzyme in the early stages of gunshot wound of dogs in seawater for exploring early treatment protocol. Methods Fourteen conventional Beagles models undergoing gunshot wound in seawater were used along with another 3 dogs receiving the wound on land to serve as control. After the dogs were rescued from the seawater, the origin of blood coming from central venous pressure tube was measured (33.75?25.29) min before and after injured for indexes such as alkaline aminotransferase (ALT) , aspartate aminotransferase (AST) , creatine kinase (CK) , creatine kinase isoenzymes - MB (CK -MB) , lactate dehydrogenase (LDH) and adenosine monophosphate (AMY) in the early stages of wound, followed by statistical analysis of the results. Results There was an increase in blood CK (P0.05). As compared with the control, the experimental group in seawater was observed to have significant difference in blood AMY (P 0.05). But it was noted that CK, CK - MB , LDH , AST and ALT contents tended to increase. Conclusion The functions of respiratory, heart, liver and kidney were injured and restrained in Beagle dogs undergoing the firearms wound in natural seawater. The immediate diagnosis and treatment of the organism as well as the out - of - wound - tract injury shoud do while the firearms primal wound tract were treated in the early stages of gunshot wound.
7.Identification of Two Microsatellite DNA Markers (Shot Tendem Repeats) on Chormo some 17 in Patients with Psoriasis Vulgaris
Hong WANG ; Weida LIU ; Hui LI
Chinese Journal of Dermatology 1994;0(02):-
Objective To investigate the association of two microsatellite mar kers, D17S784 and D17S928, with psoriasis vulgaris. Methods Fluorescent multiple x PCR, genescaning and GenotypeTM software were employed to amplify the microsat ellite DNA markers and conduct genotyping. Results The significant association w as found between D17S784, D17S928 and psoriasis vulgaris (P
8.Clinical Observation on General Anxiety Disorder Treated by Acupuncture plus Herbal Medicine
Journal of Acupuncture and Tuina Science 2007;5(4):234-237
To investigate the efficacy of the formula composed of the herbal drugs to soothe the liver, regulate qi, clarify the heart and eliminate vexation plus acupuncture for general anxiety disorder. Methods: Forty cases in the treatment group were treated with acupuncture plus herbal formula and 38 cases in the control group were treated with oral Doxepin. The assessment was conducted by Self-rating Anxiety Scale (SAS) and the Treatment Emergent Symptom Scale (TESS) before, during and after treatment. Results: The total effective rate was respectively 82.50% in the treatment group and 84.21% in the control group, with a significant difference in SAS assessment (P<0.01) between the two groups before and after the treatment.There were no significant differences in the curative and remarkable effective rate, total effective rate and SAS assessment between the two groups (P>0.05), but the side effect was higher in the control group than in the treatment group (P<0.01). Conclusion: Acupuncture plus herbal formula can have a precise effective effect for extensive anxiety neurosis with mild toxic side effects.
9.Effect of danazol on rat ectopic endometrium.
Hui ZHENG ; Hong-yi LI ; Jun DONG
Chinese Journal of Applied Physiology 2005;21(1):67-68
Animals
;
Danazol
;
pharmacology
;
Endometriosis
;
drug therapy
;
Endometrium
;
drug effects
;
Female
;
Interleukin-6
;
metabolism
;
RNA, Messenger
;
genetics
;
Rats
;
Rats, Sprague-Dawley
10.Research of the examination method of ET-CO2 based on high speed operation chip ADμC7026
Hui SHI ; Changfeng LI ; Hong SHA
International Journal of Biomedical Engineering 2010;33(2):94-98
Objective To develop one kind of mainstream ET-CO2 (carbon dioxide of the expiration tip)detector which provides accurate and real-time testing results. Methods Applying ADμC7026 as central processing unit for data pre-processing, temperature compensation algorithm and non-linear correction, the ETCO2 concentration, respiration waveform and respiration rate were obtained. Results The analyzing results of the experimental data shows that the system meets the design requirements with fine stability, rapid response, good repeatability and high accuracy. Conclusion ET-CO2 detector based on ADμC7026 makes the detection of CO2 more accurate and reliable, which provides more accurate real-time data for critical patient monitoring, anesthetic care, pediatric respiratory care and so on.