1.Training in physical examination using a cardiac patient simulator for medical students during bedside learning
Hiroyuki Komatsu ; Yasuji Arimura ; Takuroh Imamura ; Kazuo Kitamura ; Akihiko Okayama ; Katsuhiro Hayashi
Medical Education 2011;42(2):55-63
Cardiac patient simulators are commonly used in Japanese educational institutions; however, most institutions have not established concrete learning objectives or strategies for mastering physical examination of the circulatory system, including cardiac auscultation. In this study, we propose clear learning objectives and strategies for simulator practice for fifth-year medical students who have passed the objective structured clinical examination, and explored their educational effectiveness.
1)The subjects were fifth-year medical students (n=94) at the University of Miyazaki. Learning objectives were the mastery of the sequential physical examination and the ability to distinguish 6 cardiac findings, including normal status. The subjects were evaluated with a checklist before and after lectures and simulator practice.
2)The mean score (maximum score=14) significantly increased from before simulator practice (2.2±0.9) to after simulator practice (11.4±1.5; p<0.001). There was no difference in scores after practice among the cardiac diseases.
3)Before practice more than 50% of subjects could use a stethoscope on only right positions and could indicate only the maximum point of a cardiac murmur; in contrast, after practice more than 90% of the subjects could sequentially describe physical findings and accurately predict cardiac diseases.
4)In a questionnaire administered after practice, 83% of the subjects answered that all physicians should acquire proficiency in cardiac auscultation regardless of their specialty.
Simulator practice with clear learning objectives may help improve clinical examination skills when both time and human resources are limited. The reevaluation of the program's continuing educational effectiveness and the establishment of an iterative learning program will be needed.
2.A Quantitative Analysis of Factors Affecting Dispensing Errors in Community Pharmacies
Hidehiko Sakurai ; Mitsuko Onda ; Akiko Nakagawa ; Kanoko Fujimoto ; Noriko Okuda ; Hiroyuki Okayama ; Yukio Arakawa ; Yukitoshi Hayase
Japanese Journal of Drug Informatics 2013;15(3):118-123
Objective: This study quantitatively analyzes the factors causing dispensing errors in community pharmacies and explores the characteristics of these factors and their order of importance.
Design and Methods: We collected data records on the contents and causes of dispensing errors as reported between April and July 2009 by a total of 320 pharmacists at 56 stores of two pharmacy chains (15 stores in Hokkaido and 41 stores in the Kansai area). We focused on the following three types of dispensing error: 1) “measurement error”, 2) “wrong drug dispensing error” and 3) “wrong dosage form specification error”. We conducted multiple regression analyses and discriminant analyses with occurrence frequency of each type of error as dependent variables and count frequency of each causal factor as independent variables.
Results: The result of the multiple regression analyses indicated that the primary causes of the three types of errors in order of strength of the regression coefficients were as follows. For “measurement error”: 1) pharmacist’s wrong assumption and 2) calculation error; for “wrong dosage form specification error”: 1) insufficient confirmation of prescription and 2) pharmacist’s wrong assumption; for “wrong drug dispensing error”: 1) pharmacist’s wrong assumption and 2) insufficient confirmation of prescription. The results of the discriminant analysis indicated that only for the discriminant coefficient between “wrong dosage form specification error” and “wrong drug dispensing error” no significant difference in the mean was found (p=0.539).
Conclusions: Results show that partly different factors cause “measurement error” as compared with the two other types of dispensing errors. In addition, while basically the same factors were found to cause “wrong drug dispensing error” and “wrong dosage form specification error,” there was a difference in the order of importance of these factors. This study uncovered differences in terms of causal factors affecting each dispensing error type.
3.Impact of a Newly Developed Short Double-Balloon Enteroscope on Stent Placement in Patients with Surgically Altered Anatomies.
Koichiro TSUTSUMI ; Hironari KATO ; Hiroyuki OKADA
Gut and Liver 2017;11(2):306-311
A newly developed short double-balloon enteroscope with a working channel enlarged to a diameter of 3.2 mm is a novel innovation in stent placement for patients with surgically altered anatomies. Herein, we report three patients in whom this new scope contributed to an efficient technique and ideal treatment. In the first case, the double guidewire technique was efficient and effective for multiple stent placements. In the second case, covered self-expandable metal stent (SEMS) placement, which is the standard treatment for malignant biliary obstruction, could be performed in a technologically sound and safe manner. In the third case, SEMS placement was performed as palliative treatment for malignant afferent-loop obstruction; this procedure could be performed soundly and safely using the through-the-scope technique. The wider working channel of this new scope also facilitates a smoother accessory insertion and high suction performance, which reduces procedure time and stress on endoscopists. Furthermore, this new scope, which has advanced force transmission, adaptive bending, and a smaller turning radius, is expected to be highly successful in both diagnosis and therapy for various digestive diseases in patients with surgically altered anatomies.
Cholangiopancreatography, Endoscopic Retrograde
;
Diagnosis
;
Double-Balloon Enteroscopy
;
Gastric Outlet Obstruction
;
Humans
;
Palliative Care
;
Radius
;
Stents*
;
Suction
4.Association between Short Maternal Height and Low Birth Weight: a Hospital-based Study in Japan.
Sachiko INOUE ; Hiroo NARUSE ; Takashi YORIFUJI ; Tsuguhiko KATO ; Takeshi MURAKOSHI ; Hiroyuki DOI ; S V SUBRAMANIAN
Journal of Korean Medical Science 2016;31(3):353-359
Anthropometry measurements, such as height and weight, have recently been used to predict poorer birth outcomes. However, the relationship between maternal height and birth outcomes remains unclear. We examined the effect of shorter maternal height on low birth weight (LBW) among 17,150 pairs of Japanese mothers and newborns. Data for this analysis were collected from newborns who were delivered at a large hospital in Japan. Maternal height was the exposure variable, and LBW and admission to the neonatal intensive care unit were the outcome variables. Logistic regression models were used to estimate the associations. The shortest maternal height quartile (131.0-151.9 cm) was related to LBW (OR 1.91 [95% CI 1.64, 2.22]). The groups with the second (152.0-157.9 cm) and the third shortest maternal height quartiles (158.0-160.9 cm) were also related to LBW. A P trend with one quartile change also showed a significant relationship. The relationship between maternal height and NICU admission disappeared when the statistical model was adjusted for LBW. A newborn's small size was one factor in the relationship between shorter maternal height and NICU admission. In developed countries, shorter mothers provide a useful prenatal target to anticipate and plan for LBW newborns and NICU admission.
Adult
;
*Body Height
;
Body Mass Index
;
Female
;
Hospitals
;
Humans
;
*Infant, Low Birth Weight
;
Infant, Newborn
;
Intensive Care Units, Neonatal
;
Japan
;
Logistic Models
;
Male
;
Mothers/*statistics & numerical data
;
Odds Ratio
;
Risk Factors
;
Weight Gain
5.Author's Reply.
Sakiko HIRAOKA ; Jun KATO ; Hiroyuki OKADA
Intestinal Research 2018;16(2):321-322
No abstract available.
Tumor Necrosis Factor-alpha
;
Crohn Disease
;
Adrenal Cortex Hormones
6.Comparison of Bilateral and Trisegment Drainage in Patients with High-Grade Hilar Malignant Biliary Obstruction: A Multicenter Retrospective Study
Kazuyuki MATSUMOTO ; Hironari KATO ; Kosaku MORIMOTO ; Kazuya MIYAMOTO ; Yosuke SARAGAI ; Hirofumi KAWAMOTO ; Hiroyuki OKADA
Gut and Liver 2023;17(1):170-178
Background/Aims:
Bilateral endoscopic drainage with self-expanding metallic stent (SEMS) can be used to effectively manage hilar malignant biliary obstruction. However, the benefits of using a trisegment drainage method remain unknown.
Methods:
This study retrospectively reviewed the data of 125 patients with Bismuth type IIIa or IV unresectable malignant strictures who underwent bilateral endoscopic drainage using SEMSs at four tertiary centers. The patients were divided into the bilateral and trisegment drainage groups for comparison. The primary endpoint was stent patency and the secondary endpoints were technical success, technical and clinical success of reintervention, and overall survival.
Results:
The technical success rates of the bilateral and trisegment drainage groups were 95% (34/36) and 90% (80/89) (p=0.41), respectively, with median stent patency durations of 226 and 170 days (p=0.26), respectively. Although the technical success of reintervention was not significantly different between the two groups (p=0.51), the clinical success rate of reintrvention was significantly higher in the trisegment drainage group (73% [11/15] vs 96% [47/49], p=0.009). The median survival times were 324 and 323 days in the bilateral and trisegment drainage groups, respectively (p=0.72). Multivariate Cox hazards model revealed no stent patency-associated factor; however, chemotherapy was associated with longer survival.
Conclusions
Although no significant difference was noted with respect to stent patency, significantly higher clinical success rates were achieved with reintervention using the trisegment drainage method than using the bilateral drainage method alone.
7.Endoscopic Ultrasound-Guided Transgastric Drainage of an Intra-Abdominal Abscess following Gastrectomy
Satoru KIKUCHI ; Tetsushi KUBOTA ; Shinji KURODA ; Masahiko NISHIZAKI ; Shunsuke KAGAWA ; Hironari KATO ; Hiroyuki OKADA ; Toshiyoshi FUJIWARA
Clinical Endoscopy 2019;52(4):373-376
Endoscopic ultrasound (EUS)-guided transgastric drainage has been performed as a less invasive procedure for pancreatic fistulas and intra-abdominal abscesses occurring after surgery in recent years. However, there are no reports of EUS-guided transgastric drainage of intra-abdominal abscesses following gastrectomy. This case report describes 2 patients who developed an intra-abdominal abscess following gastrectomy and underwent EUS-guided transgastric drainage. Both patients underwent laparoscopy-assisted distal gastrectomy with Billroth-I reconstruction for gastric cancer. The intra-abdominal abscesses were caused by postoperative pancreatic fistula that developed following gastrectomy. One patient underwent naso-cystic drainage and the other underwent only a needle puncture of the abscess cavity. EUS-guided drainage was performed safely and effectively, although 1 patient developed gastroduodenal anastomotic leakage related to this procedure. In summary, EUS-guided transgastric drainage is safe and technically feasible even in post-gastrectomy patients. However, it is necessary to be careful if this procedure is performed in the early period following gastrectomy.
Abdominal Abscess
;
Abscess
;
Anastomotic Leak
;
Drainage
;
Gastrectomy
;
Humans
;
Needles
;
Pancreatic Fistula
;
Punctures
;
Stomach Neoplasms
;
Ultrasonography
8.Diagnostic Ability of Convex-Arrayed Endoscopic Ultrasonography for Major Vascular Invasion in Pancreatic Cancer
Yuki FUJII ; Kazuyuki MATSUMOTO ; Hironari KATO ; Yosuke SARAGAI ; Saimon TAKADA ; Sho MIZUKAWA ; Shinichiro MURO ; Daisuke UCHIDA ; Takeshi TOMODA ; Shigeru HORIGUCHI ; Noriyuki TANAKA ; Hiroyuki OKADA
Clinical Endoscopy 2019;52(5):479-485
BACKGROUND/AIMS: This study aimed to examine the diagnostic ability of endoscopic ultrasonography (EUS) for major vascular invasion in pancreatic cancer and to evaluate the relationship between EUS findings and pathological distance. METHODS: In total, 57 consecutive patients who underwent EUS for pancreatic cancer before surgery were retrospectively reviewed. EUS image findings were divided into four types according to the relationship between the tumor and major vessel (types 1 and 2: invasion, types 3 and 4: non-invasion). We also compared the EUS findings and pathologically measured distances between the tumors and evaluated vessels. RESULTS: The sensitivity, specificity, and accuracy of EUS diagnosis for vascular invasion were 89%, 92%, and 91%, respectively, in the veins and 83%, 94%, and 93%, respectively, in the arteries. The pathologically evaluated distances of cases with type 2 EUS findings were significantly shorter than those of cases with type 3 EUS findings in both the major veins (median [interquartile range], 96 [0–742] µm vs. 2,833 [1,076–5,694] µm, p=0.012) and arteries (623 [0–854] µm vs. 3,097 [1,396–6,000] µm, p=0.0061). All cases with a distance of ≥1,000 µm between the tumors and main vessels were correctly diagnosed. CONCLUSIONS: Tumors at a distance ≥1,000 µm from the main vessels were correctly diagnosed by EUS.
Arteries
;
Diagnosis
;
Endosonography
;
Humans
;
Pancreatic Neoplasms
;
Retrospective Studies
;
Sensitivity and Specificity
;
Veins
9.Does Helicobacter pylori Exacerbate Gastric Mucosal Injury in Users of Nonsteroidal Anti-Inflammatory Drugs? A Multicenter, Retrospective, Case-Control Study.
Yoshiyasu KONO ; Hiroyuki OKADA ; Ryuta TAKENAKA ; Ko MIURA ; Hiromitsu KANZAKI ; Keisuke HORI ; Masahide KITA ; Takao TSUZUKI ; Seiji KAWANO ; Yoshiro KAWAHARA ; Kazuhide YAMAMOTO
Gut and Liver 2016;10(1):69-75
BACKGROUND/AIMS: The interaction between nonsteroidal anti-inflammatory drugs (NSAIDs) and Helicobacter pylori remains controversial. We retrospectively investigated whether H. pylori infection exacerbates severe gastric mucosal injury among chronic NSAID users. METHODS: From January 2010 to December 2013, a total of 245 long-term NSAID (including low-dose aspirin) users who had undergone an esophagogastroduodenoscopy and had been evaluated for H. pylori infection were enrolled at Okayama University Hospital and Tsuyama Chuo Hospital. The degree of gastric mucosal injury was assessed according to the modified Lanza score (MLS). Severe gastric mucosal injury was defined as an MLS > or =4. Univariate and multivariate logistic regression analyses were performed. RESULTS: In the univariate analysis, age > or =75 years (odds ratio [OR], 2.4; 95% confidence interval [CI], 1.3 to 4.2), H. pylori-positivity (OR, 2.0; 95% CI, 1.2 to 3.5), and the concomitant use of proton pump inhibitors (PPIs) (OR, 0.48; 95% CI, 0.26 to 0.86) were significantly associated with severe gastric mucosal injury. The multivariate analysis was adjusted by age and sex and demonstrated that H. pylori-positivity (OR, 1.8; 95% CI, 1.0 to 3.3) and the concomitant use of PPIs (OR, 0.53; 95% CI, 0.28 to 0.99) significantly contributed to severe gastric mucosal injury. CONCLUSIONS: H. pylori infection exacerbates severe gastric mucosal injury among chronic NSAID users.
Aged
;
Anti-Inflammatory Agents, Non-Steroidal/*adverse effects
;
Case-Control Studies
;
*Disease Progression
;
Endoscopy, Digestive System
;
Female
;
Gastric Mucosa/*drug effects/*microbiology
;
Helicobacter Infections/*complications/microbiology/pathology
;
*Helicobacter pylori/drug effects
;
Humans
;
Logistic Models
;
Male
;
Middle Aged
;
Odds Ratio
;
Proton Pump Inhibitors/adverse effects
;
Retrospective Studies
10.Magnifying Endoscopy for Intestinal Follicular Lymphoma Is Helpful for Prompt Diagnosis.
Masaya IWAMURO ; Masato OKUDA ; Eiichiro YUMOTO ; Seiyuu SUZUKI ; Atsuko SHIRAKAWA ; Katsuyoshi TAKATA ; Tadashi YOSHINO ; Hiroyuki OKADA ; Kazuhide YAMAMOTO
Gut and Liver 2013;7(2):258-261
The representative endoscopic features of primary intestinal follicular lymphoma are well known as small whitish polypoid nodules, but a magnified view has only been described in a few case reports. Herein, we report a case with intestinal follicular lymphoma in which magnifying endoscopy with narrow band imaging was helpful for prompt diagnosis. A 57-year-old Japanese woman underwent surveillance esophagogastroduodenoscopy. The endoscopic examination revealed confluent whitish granules in the duodenum, distinct from the nodules or polyps that are typical findings of intestinal follicular lymphoma. Magnifying endoscopy visualized whitish enlarged villi, and narrow band imaging emphasized an elongated and coiled vascular pattern. Based on these features, intestinal follicular lymphoma was highly suspected, and subsequent histological study confirmed the diagnosis. This case demonstrates that magnifying endoscopy with narrow band imaging was useful for the detection and prompt diagnosis of intestinal follicular lymphoma. The pathological features of intestinal follicular lymphoma are also discussed.
Asian Continental Ancestry Group
;
Duodenal Neoplasms
;
Duodenum
;
Endoscopes, Gastrointestinal
;
Endoscopy
;
Endoscopy, Digestive System
;
Female
;
Humans
;
Lymphoma, Follicular
;
Narrow Band Imaging
;
Polyps