1.Tissue culture of medicinal plant Swertia mileensis
Chinese Traditional and Herbal Drugs 1994;0(02):-
Objective In order to preserve the natural resources of Swertia mileensis which has been destroyed seriously, the method of artificial propagation by way of tissue culture has been systematically studied. Methods The immature stems and the mature leaves were the best material explants in rapid propagation in all of the experiments. These explants were cultured on MS culture media by adding different portions of hormones at various cultural conditions. Results For the leaves, the suitable phytohormone combination to induce callus are Zt 0.5 mg/L+NAA 0.1 mg/L+IBA 0.1 mg/L or BA 0.5 mg/L+2,4-D 0.1 mg/L+IBA 0.1 mg/L; for the stems, they are BA 0.02 mg/L+Kt 0.04 mg/L+IBA 0.05 mg/L; for the adventitious buds, they are BA 2.0 mg/L+NAA 0.5 mg/L or BA 2.0 mg/L+IBA 0.1 mg/L; and for the roots, they are MS+Kt 0.01 mg/L+IBA 0.5 mg/L+NAA 1.0 mg/L. Conclusion Tissue culture of S. mileensis can make its propagation rapid, its resources preserved, and its utilization last.
2.Tissue culture of Swertia bimaculata
Hua LONG ; Xuefeng HU ; Hengyu HUANG
Chinese Traditional and Herbal Drugs 1994;0(03):-
Objective In order to protect the natural resources of Swertia bimaculata which has been destroyed seriously,the method of artificial propagation by way of tissue culture have been systematically studied.Methods The stems,leaves,and stems with buds which were from the seedlings germinated from the seeds on the initial medium were taken as explants.These explants were cultured on MS culture media by adding different portions of hormones at various cultural conditions.Results The stems were the best material in speeding propagation among the three explants.The proper initial medium for the stems was MS+ BA 0.5 mg/L+saccharose 3.0%,the optimum medium for proliferation was MS+BA 0.5 mg/L+IBA 0.1 mg/L+saccharose 3.0%,and the best medium for rooting was 1/2MS+NAA 0.5 mg/L+saccharose 1.5%.Conclusion Tissue culture of S.bimaculata could make its propagation rapid,its resources preserved,and its utilization last.
4.Proximal and distal ends of thoracodosal artery and vein as recipient vessels for immediate breast reconstructions using deep inferior epigastric perforator flap in four cases
Xiuxiu CHEN ; Huangfu WU ; Lan MU ; Wuping ZHENG ; Junbo PAN ; Guisheng HE ; Tao SONG ; Yazhen ZHANG ; Hengyu CHEN ; Jinghui HUANG ; Yilian XU
Chinese Journal of Plastic Surgery 2024;40(5):507-513
Objective:Explore the feasibility and advantages of using proximal and distal ends of thoracodosal artery and vein as recipient vessels in deep inferior epigastric perforator flap immediate breast reconstruction.Methods:The clinical data of patients who underwent breast reconstruction surgery using the proximal and distal ends of the thoracodorsal vein as recipient vessels at the Department of Breast and Thyroid Surgery of the Second Affiliated Hospital of Hainan Medical University from March 2022 to June 2023 were analyzed retrospectively. Preoperative examinations included thoracoabdominal angiography and color Doppler ultrasonic localization of the main trunk and perforators of the inferior epigastric vessels. The procedure began with mastectomy and axillary lymph node dissection, followed by the isolation of bilateral perforators and the main trunk of the abdominal flap. The main trunks of the bilateral inferior epigastric arteries were then transected, and their vascular pedicles exposed and anastomosed respectively to the proximal and distal ends of the thoracodorsal artery and vein. Both arteries and veins were joined end-to-end. The flap after trimming and reconstruction was then implanted into the cavity left after mastectomy through the incision. Breast positioning was performed with the patient in a knee-bent and hip-flexed position. After adjusting the shape of the reconstructed breast. The donor site was closed, the umbilicus was reconstructed, drainage tubes were placed, and the breast incision was closed. Postoperative follow-up monitored complications associated with the flap and patient satisfaction with the breast reconstruction, utilizing a self-assessment method.Results:Four female patients were included, aged (46.0±6.5) years, ranging from 37 to 52 years. All four patients had bilateral vascular pedicles in the donor area, with three patients having thoracodorsal vessels at the distal and proximal ends as recipient vessels, and one patient having anterior serratus branch of the thoracodorsal vessels at the distal and proximal ends. All drainage tubes were removed within 7 to 10 days after surgery. Patients were discharged. Follow-up period ranged from 1 to 15 months, averaging 6 months. The patients recovered well postoperatively, with no flap-related complications occurring. All four patients were satisfied with the result of the reconstruction.Conclusion:The simultaneous application of the proximal and distal ends of the thoracodorsal artery and vein can ensure the safety of flap survival while reducing damage to the ribs and intercostal muscles, achieving better aesthetic result.
5.Proximal and distal ends of thoracodosal artery and vein as recipient vessels for immediate breast reconstructions using deep inferior epigastric perforator flap in four cases
Xiuxiu CHEN ; Huangfu WU ; Lan MU ; Wuping ZHENG ; Junbo PAN ; Guisheng HE ; Tao SONG ; Yazhen ZHANG ; Hengyu CHEN ; Jinghui HUANG ; Yilian XU
Chinese Journal of Plastic Surgery 2024;40(5):507-513
Objective:Explore the feasibility and advantages of using proximal and distal ends of thoracodosal artery and vein as recipient vessels in deep inferior epigastric perforator flap immediate breast reconstruction.Methods:The clinical data of patients who underwent breast reconstruction surgery using the proximal and distal ends of the thoracodorsal vein as recipient vessels at the Department of Breast and Thyroid Surgery of the Second Affiliated Hospital of Hainan Medical University from March 2022 to June 2023 were analyzed retrospectively. Preoperative examinations included thoracoabdominal angiography and color Doppler ultrasonic localization of the main trunk and perforators of the inferior epigastric vessels. The procedure began with mastectomy and axillary lymph node dissection, followed by the isolation of bilateral perforators and the main trunk of the abdominal flap. The main trunks of the bilateral inferior epigastric arteries were then transected, and their vascular pedicles exposed and anastomosed respectively to the proximal and distal ends of the thoracodorsal artery and vein. Both arteries and veins were joined end-to-end. The flap after trimming and reconstruction was then implanted into the cavity left after mastectomy through the incision. Breast positioning was performed with the patient in a knee-bent and hip-flexed position. After adjusting the shape of the reconstructed breast. The donor site was closed, the umbilicus was reconstructed, drainage tubes were placed, and the breast incision was closed. Postoperative follow-up monitored complications associated with the flap and patient satisfaction with the breast reconstruction, utilizing a self-assessment method.Results:Four female patients were included, aged (46.0±6.5) years, ranging from 37 to 52 years. All four patients had bilateral vascular pedicles in the donor area, with three patients having thoracodorsal vessels at the distal and proximal ends as recipient vessels, and one patient having anterior serratus branch of the thoracodorsal vessels at the distal and proximal ends. All drainage tubes were removed within 7 to 10 days after surgery. Patients were discharged. Follow-up period ranged from 1 to 15 months, averaging 6 months. The patients recovered well postoperatively, with no flap-related complications occurring. All four patients were satisfied with the result of the reconstruction.Conclusion:The simultaneous application of the proximal and distal ends of the thoracodorsal artery and vein can ensure the safety of flap survival while reducing damage to the ribs and intercostal muscles, achieving better aesthetic result.
6.Quality control testing and performance evaluation of polysomnography
Jing HUANG ; Li YANG ; Aowen DUAN ; Li XU ; Zhenwei DU ; Hengyu LONG ; Anhai WEI ; Kexin PAN
China Medical Equipment 2024;21(5):123-127
Objective:To research the quality control and testing methods of polysomnography and to ensure its safe and effective performance.Methods:A quality control testing method was designed for the main indicators of EEG signal,EMG signal,ECG signal,and pulse oxygen saturation of polysomnography.In August 2023,two polysomnography instruments of the same brand and different models(marked as Test Equipment A and Test Equipment B)in clinical use in Daping Hospital,Army Medical University were selected.The quality control testing of polysomnography instrument was conducted by using electroencephalogram calibration instrument and vital sign simulator to evaluate the reliability of the performance of polysomnography.Results:A quality control testing method was developed for quality control testing of polysomnography aiming at the repeatability of the indicated values of EEG signals,EMG signals,ECG signals,and pulse oxygen saturation of polysomnography.Except for the output value of 2 mV of the voltage measurement simulator of test equipment B,the relative error of the recorded data was-11%,and the parameters were out of tolerance,and the rest of the test data of test equipment A and test equipment B met the maximum limit output value of the national metrology verification regulations and the technical requirements of the equipment manufacturer.Conclusion:The quality control detection method of polysomnography can evaluate the performance parameters of the selected testing equipment A and testing equipment B,and provide technical support for the quality control detection and safe use of such equipment.
7.Research on calibration method of endoscopic liquid expansion pump
Jing HUANG ; Aowen DUAN ; Li YANG ; Xiaobo WEN ; Haijiang ZHU ; Anhai WEI ; Hengyu LONG ; Hehua ZHANG
China Medical Equipment 2024;21(10):194-197
A corresponding calibration method was proposed for the key performance parameters of the endoscopic liquid expansion pump,such as the pressure indication error,the flow rate indication error and the flow rate repeatability.4 different brands of endoscopic liquid expansion pumps in clinical use in the hospital were selected for calibration,and the feasibility of the calibration method was evaluated.In the pressure and flow range of the endoscope liquid expansion pump,3 calibration points of high,medium and low were selected,and each flow point was calibrated 3 times.The calibration results showed that the maximum error of pressure indication was 4.3%,the maximum error of flow indication was 9.3%,and the maximum repeatability of flow indication value was 0.8%,all of which met the technical requirements for the maximum allowable error of"Medical Endoscopes.Endoscope Functional Supply Units.Irrigation Pump"(YY/T 0864-2011)and"Calibration Specification for Syringe Pumps and Infusion Pumps"(JJF 1259-2018).The calibration method for endoscopic liquid expansion pump can improve the metrological traceability system of this type of equipment,ensure the accuracy and reliability of equipment values,improve product quality,and ensure medical safety.
8.Development of diagnosis, assessment and intervention solution for speech fluency disorder using WHO-FICs
Minmin YIN ; Xing LING ; Yaru YANG ; Hengyu DAI ; Shengnan GE ; Zhaoming HUANG
Chinese Journal of Rehabilitation Theory and Practice 2022;28(6):630-636
ObjectiveTo explore the diagnoses of diseases and functioning of speech fluency disorder, analyze the main assessment content, and construct framework of intervention solution based on International Classification of Diseases 11th Revision (ICD-11), International Classification of Functioning, Disability and Health (ICF) and International Classification of Health Interventions (ICHIβ-3). MethodsThe diagnoses of diseases and functioning was discussed with ICD-11 and ICF. The assessment tools were analyzed with ICF. A holistic intervention solution was constructed with ICF and ICHIβ-3. ResultsSpeech fluency disorder is classified as 6A01.1 developmental speech fluency disorder for ICD-11. The related diseases include 6A01.0 developmental speech sound disorder, 6A01.2 developmental language disorder, cerebral palsy, MA80.0 aphasia, MA80.1 dysphasia and MA80.2 dysarthria, etc. For ICF, the categories related to speech fluency disorder might be s3 structures invovled in voice and speech; b3 voice and speech functions, especially b330 fluency and rhythm of speech functions; d1 learning and applying knowledge, d3 communication, especially d330 speaking and d355 discussion, d7 interpersonal interactions and relationships, and d9 community, social and civic life. A holistic intervention solution for speech fluency disorder was developed, involving in body structure, body function, activities and participation, and environmental factors, including assessment, training and treatment, educational counseling, and psychological and social support, etc. ConclusionA framework of diagnosis, assessment and rehabilitation has been constructed for speech fluency disorder.