1.Excessive production of nicotinamide adenine dinucleotide phosphate oxidase 4-dependent reactive oxygen species suppresses cardiomyocyte differentiation from embrvonic stem cells
Xiaoyong ZHANG ; Hanbang GUO ; Jian LI
Chinese Journal of Tissue Engineering Research 2007;11(7):1386-1390,封3
BACKGROUND: Reactive oxygen species (ROS), including superoxide anion (O2) and hydrogen peroxide (H2O2), have been recognized as specific second messengers in signaling cascades involved in the growth and differentiation of cells.The generation of excessive ROS initiates cardiomyocyte apoptosis. This paper is aimed to corroborate the hypothesis that excessive amounts of nicotinamide adenine dinucleotide phosphate (NADPH) oxidase (NOX) 4-dependent ROS can suppress cardiomyocyte differentiation from embryonic stem (ES) cells by induction of apoptosis.OBJECTIVE: To investigate the role of NOX4 ROS on cardiomyocyte differentiation.DESIGN: Randomized and controlled trial observation.SETTING: Beijing Institute of Geriatrics, Beijing Hospital, Key Laboratory of Geriatrics, Ministry of Health.MATERIALS: ES cells were preserved by the laboratory of Beijing Institute of Geriatrics, Beijing Hospital, Key Laboratory of Geriatrics, Ministry of Health, while other reagents were purchased from Sigma Company without specific notification.METHODS: The experiment was carried out in the Beijing Institute of Geriatrics, Beijing Hospital, Key Laboratory of Geriatrics, Ministry of Health from October 2003 to August 2005. ①Mouse ES cells were differentiated into embryoid bodies (Ebs). At day 4, Ebs were managed for one hour with different concentrations (1, 10, 100, 1 000 nmol/L) of H2O2, and generation of cardiomyocytes was observed at day 8 to analyze the effect of ROS on cardiomyocyte differentiation.② CGB8 cells transfected with pcDNA3.1 and pcDNA3.1-NOX4 respectively were adopted, while those untransfected CGB8 cells were taken as controls. A quantitative NBT (nitro blue tetrazolium) test was used to measure NOX4 ROS generation. The levels of NOX4 mRNA and MLC2v protein were assayed by RT-PCR and western blotting, respectively.③ROS scavenger N-acetylcysteine (5 mmol/L) and catalase (200 U/mL) managed for 2 hours before transcription were taken as controls to observe the apoptosis of CGB8 cell after NOX4 overexpressed and the expressions of p21, p53 and Bcl-2 of NOX4-transfected CGB8 cells simultaneously. And the apoptosis of ES cells was detected by Hoechst staining, TUNEL assay and DNA fragmentation.MAIN OUTCOME MEASURES: ①the role of ROS on cardiomyocyte differentiation.②the expression of NOX in ES cells.③ the production of ROS, differentiation of cardiomyocyte and apoptosis of ES cells after NOX4 overexpressed.④the feasibility that p53, p21 and Bcl-2 are involved in the apoptosis induced by the overexpression of NOX4.RESULTS: ①Different concentrations of ROS play different roles on cardiomyocyte differentiation. The exposure of Ebs to 1-100 nmol/L H2O2 for 2 hours at day 4 of culture leaded to an enhanced beating activity (P < 0.01 or 0.001), whereas 1 μmol/L H2O2 depressed cardiomyocyte differentiation as compared with control conditions (P < 0.001). ②NOX4 was highly expressed in ES cells, while NOX1 and NOX2 were absent and only a weak band of NOX3 was detected. The results from RT-PCR revealed that NOX4 overexpressed in CGR8 transfected with pcDNA3.1-NOX4 as compared to the control.③NBT result proved that highly-expressed NOX4 produced the excessive amounts of ROS (P < 0.05). The beating activity was remarkably reduced in NOX4-overexpressing Ebs as compared to wild-type or mock-transfected Ebs (P <0.01). Moreover, a severe reduction of MLC2v protein in NOX4-overexpressing Ebs was also observed by western blot analysis.④p21 and p53 may be responsible for the NOX4-induced apoptosis. P53-/- cells R72D27 transfected by NOX4 did not induce apoptosis. NOX4 overexpression induced ES cell apoptosis could be prevented by overexpression of Bcl-2.CONCLUSION: The findings of this paper highlight the role of NADPH oxidase NOX4 in cardiomyocyte differentiation from ES cells. P53, p21 and Bcl-2 could be involved in the apoptotic pathway.
2.Resolution of Optical Isomers of α-Hydroxy-acetones byHigh Resolution Gas Chromatography on Chiral Stationary Phase
Yueqin ZHANG ; Xueyan SHI ; Ruonong FU ; Hanbang ZHANG ; Yun LING ; Xiaobin ZUO ; Hanfan LIU
Chinese Journal of Analytical Chemistry 2001;29(3):336-338
Using the cyclodextrin bonded polysiloxane (bikis〔(2,6-di-O-pentyl-3-O-hex-6-O-enyl)-pentakis(2,6-di-O-pentyl-3-O-methyl)-β-cyclodextrm-polysiloxane〕) as gas chromatographic stationary phase, α-hydroxy acetones were separated and the values of the enantiomeric excess(e.e) of 3-hydroxy-2-butanone were determined. The results showed that the high resolution gas chromatography (HRGC) using the chiral gas chromatographic stationary phase could determine the productive rate of the asymmetric hydrogenaton reaction and evaluate the enantoselectivity of the catalyst system.
3.Evaluation of the Performance of 7 homogeneous direct reagents for HDL-cholesterol
Haijian ZHAO ; Hanbang GUO ; Chuanbao ZHANG ; Hongxia LI ; Jun DONG ; Shu WANG ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2009;32(5):521-525
Objective To evaluate the analytical performance of 7 homogeneous HDL-cholesterol reagents. Methods An altracentrifugation-HPLC method was used as the comparison method. Fourty fresh patient samples were analyzed by homogeneous methods and the comparison method. The homogeneous methods were all performed on a Hitachi 7170A chemistry analyzer according to the manufacturer's instructions, Precision, accuracy and total errors were analyzed. Results The homogeneous assays typically demonstrated within run coefficient variance(CV) of < 1%, and total CV of < 3%. Methods A, B and D showed average bias, bias at the medical decision points and total errors all within the NCEP performance criteria and method C and F unacceptable biases (-19.74% and 11.46%, respectively) and total errors according to the NCEP criteria. However, all the homogenous methods (A-F) had total errors of < 30%, as required by the US Clinical Laboratory Improvement Amendment (CLIA). Conclusions Homogeneous HDL-C assays have been shown to be reasonably precise, but discrepant results have been observed with some of the assays. Clinical laboratories should pay more attention on selecting and validating homogeneous HDL-C reagents.
4.Stability of serum total and high density lipoprotein cholesterol during whole blood incubation examined by high performance liquid chromatography
Jiangtao ZHANG ; Jun DONG ; Hongxia LI ; Hanbang GUO ; Yong MAN ; Shu WANG ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2001;0(04):-
Objective To examine the changes of serum total and high density lipoprotein cholesterol during whole blood incubation and to investigate the possible mechanisms responsible for the instability.Methods A method for the measurement of serum total cholesterol (TC), total free cholesterol (TFC), high density lipoprotein cholesterol (HDLC) and high density lipoprotein free cholesterol (HDLFC) by high performance liquid chromatography (HPLC) was developed. Whole blood specimens were incubated at 25℃ and 4℃ for various period of time and serum TC, TFC, HDLC and HDLFC were measured.Results The new HPLC method showed a mean within-run CV of 0.22%~0.51%. The averaged changes during the incubations ranged 0.6%~2.0% for TC and 2.0%~4.1% for HDLC.Conclusion An HPLC method has been established that is highly precise and can be used for detecting subtle cholesterol changes in biological samples. Different cholesterol exchanges or transfers between blood cells and lipoproteins exist during various incubations. Prolonged whole blood storage that causes serum TC and HDLC changes should be avoided in clinical lipid measurements.
5.Determination of serum cotinine by isotope dilution liquid chromatography tandem mass spectrometry
Ruiyue YANG ; Weiyan ZHOU ; Tianjiao ZHANG ; Hanbang GUO ; Hongxia LI ; Shu WANG ; Jun DONG ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2012;35(4):333-338
Objective To establish a method for measuring serum cotinine by isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) and provide an assay that can be applied to theevaluation of the level of smoke exposure and to the risk analysis of smoking related diseases.Methods Blood samples were collected from 94 apparently healthy subjects from October to December in 2010 and centrifuged,and the sera were separated.Serum samples were mixed with [ D3 ] -cotinine ( as the internal standard) and treated with acetonitriles to precipitate protein.After centrifugation,the supernatants were transferred and evaporated under a stream of nitrogen until dryness and reconstituted with mobile phase.Then the residuals were analyzed by LC/MS/MS system with multiple reaction monitor model; the concentration of cotinine were quantified by the isotope internal standard method and the stand curve was employed with a series of calibration.To estimate the precision of the method,five frozen serum pools were repeatedly analyzed in five runs,and every pool was analyzed in triplicate.In addition,the recovery rates were analyzed with the serum sample added with different levels of standard.The stability of cotinine in serum preserved at room temperature,4 ℃ and - 80 ℃,respectively.Finally,the levels of cotinine of 94 healthy subjects were measured to evaluate the distribution of cotinine with different smoke statuses.Results Serum cotinine measured by ID-LC/MS/MS was separated well with few interferences.The correlation coefficients between the peak area ratios and cotinine concentrations were higher than 0.9993.The values of within-run coefficients of variation (CV) of five frozen serum pools (0.68,48.42,94.34,250.95 and 287.04 μg/L) were 2.19%,0.78%,0.75%,0.65% and 0.67%,respectively.The values of total CV were 4.71%,1.40%,1.98%,1.10% and 1.03%,respectively.The limit of detection (LOD) and limit of quantitation ( LOQ ) were 0.013 and 0.050 μg/L,respectively.The analytical recoveries ranged from 99.22% to 102.67%.The samples could maintain stability within 2 d at room temperature,7 d at 4 ℃ and 3 months at -80 ℃ resulting the accuracy of measurements from 99.28% to 100.87% and the CV<5%.The levels of cotinine of 94 healthy subjects were measured and shown skewed and leptokurtic distribution.The concentrations of twenty smokers,fourteen former smokers and sixty non-smokers were 116.40 (63.17 -241.12),0.67 (0.15 - 0.95 ) and 0.22 (0.15 - 0.42 ) μg/L,respectively.Furthermore,the level of cotinine of former smokers (Z =-2.12,P <0.05) and smokers (Z =-6.67,P <0.001) were statistically higher than non-smokers.Conclusions An ID-LC/MS/MS method for serum cotinine detection has been established.It is hoped that the method will be applied to the assessment of smoke exposure and its association with the risks of smoking related diseases since it is simple,specific,precise,sensitive and accurate.