1.Paramedics’ Perception on Video Assisted Learning Method in Learning Emergency Skills
Bala Krishnian M ; Ahmad Khaldun I ; Hamidah Y ; Johar MJ ; Ismail MS
Medicine and Health 2016;11(1):47-55
Information technology use in healthcare education has become a popular
medium of instruction. One of the medium of instruction is video assisted learning
(VAL). The use of VAL as an instructional method in the teaching and learning of emergency skills is not new. However, there are lack of studies on the perception of
using this method in learning emergency skills. This qualitative study involved four
focused discussion groups following a VAL instruction on emergency skills. A total
of 20 paramedics were divided into four groups. They were involved in a focussed
discussion after a VAL instruction session. Findings reveal that the paramedics
perceived three major themes which were categorized as : i) advantages of video
as teaching tool, ii) barrier in using video as a teaching tool; and iii) suggestions on
using video as teaching tool. The findings indicate that the paramedics perceived
VAL as a potential tool for learning emergency skills. However, they suggested the
language of instruction should be in their mother tongue for better understanding.
This implies that using English language has disadvantage in technology enhanced
learning for better understanding.
Computer-Assisted Instruction
2.Detection of Partial G6PD Deficiency using OSMMR2000-D Kit with Hb Normalization
Azma RZ ; Siti Zubaidah M ; Azlin I ; Hafiza A ; Nurasyikin Y ; Nor Hidayati S ; Noor Farisah AR ; Noor Hamidah H ; Ainoon O
Medicine and Health 2014;9(1):11-21
Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzyme deficiency worldwide including Malaysia. Screening of cord blood for partial G6PD deficiency is important as they are also prone to develop acute haemolysis. In this study, we determined the prevalence of partial G6PD deficient in paediatric population aged 1 month-12 years and normal term female neonates using OSMMR-D kit with haemoglobin (Hb) normalization and compare it with florescence spot test (FST). A total of 236 children, aged between between 1
month-12 years and 614 normal term female neonates were recruited for this study. Determination of normal means for G6PD activity and; cut-off points for partial and severe deficiency were determined according to WHO Working Group (1989). Determination of prevalence for partial deficiency for both groups (female patient) was done using this enzyme assay kit and findings were compared with FST. In this study, 15.7% (18/115) female children were classified as partial G6PD deficient by quantitative enzyme method (G6PD activity: 4.23-5.26U/gHb). However, FST only detected 0.9% (1/115) with minimal G6PD activity. The prevalence of partial G6PD deficiency in female neonate group was 3.42% (21/614) by enzyme assay versus
0.49% (3/614) by FST. This study concluded that our routine screening method using FST was unable to diagnose female heterozygotes. We recommend using this quantitative enzyme assay method by OSMMR-D kit since it was more sensitive in detecting G6PD deficiency in female neonates compared to FST.
Glucosephosphate Dehydrogenase Deficiency