1.Diagnosis and treatment of colorectal liver metastases: Chinese expert consensus-based multidisciplinary team (2024 edition).
Wen ZHANG ; Xinyu BI ; Yongkun SUN ; Yuan TANG ; Haizhen LU ; Jun JIANG ; Haitao ZHOU ; Yue HAN ; Min YANG ; Xiao CHEN ; Zhen HUANG ; Weihua LI ; Zhiyu LI ; Yufei LU ; Kun WANG ; Xiaobo YANG ; Jianguo ZHOU ; Wenyu ZHANG ; Muxing LI ; Yefan ZHANG ; Jianjun ZHAO ; Aiping ZHOU ; Jianqiang CAI
Chinese Medical Journal 2025;138(15):1765-1768
2.Ferroptosis: a potential new therapeutic target for myocardial injury induced by acute carbon monoxide poisoning.
Anping LIU ; Xuheng JIANG ; Tianjing SUN ; Mo LI ; Haizhen DUAN ; Shuhong WANG ; Anyong YU
Chinese Critical Care Medicine 2025;37(4):407-412
Acute carbon monoxide poisoning (ACMP) is one of the most common gas poisonings in the emergency department, with tens of thousands of people seeking medical attention for carbon monoxide (CO) poisoning each year. The severity of poisoning is dependent upon environmental and human factors, with hypoxia and oxidative stress being important mechanisms of cardiac toxicity induced by CO. Myocardial involvement is common in moderate to severe ACMP, including myocardial injury, myocardial infarction, arrhythmia, and sudden death, which are associated with a high risk of death. Ferroptosis is a cell death mechanism caused by iron-dependent lipid peroxidation (LPO), although ferroptosis has been shown to play a critical role in various cardiovascular diseases, the potential mechanism by which it contributes to ACMP-induced myocardial injury is unclear. This review discusses the established link between ferroptosis and cardiovascular disease and summarizes the potential role of ferroptosis in ACMP-induced myocardial injury and the detrimental effects of ACMP on the heart. Elucidating these mechanisms could guide the development of novel therapeutic strategies that target ferroptosis to mitigate ACMP-induced myocardial injury. This review aims to provide a theoretical foundation for future research on the potential use of ferroptosis as a therapeutic target for ACMP-induced myocardial injury.
Humans
;
Carbon Monoxide Poisoning/complications*
;
Ferroptosis
;
Lipid Peroxidation
;
Myocardium/pathology*
;
Oxidative Stress
3.Analysis of factors associated with acute hematologic toxicity in patients receiving chemoradiotherapy for cervical cancer
Haizhen YUE ; Jing YOU ; Hao WU ; Xiaoyan JIANG ; Jinsheng CHENG ; Kuke DING
Chinese Journal of Radiological Health 2024;33(4):440-446
Objective To investigate the clinical characteristics and dosimetric parameters associated with acute hematologic toxicity (AHT) resulting from radiation-induced damage to hematopoietic organs in patients undergoing chemoradiotherapy for cervical cancer and to provide a reference for establishing dose constraints in relevant regions of interest (ROIs) and predicting adverse tissue reactions during the development of clinical treatment plans. Methods A retrospective analysis was conducted on 556 patients with cervical cancer who underwent chemoradiotherapy at our hospital. Univariate (χ2 and t-test) and multivariate (binary logistic regression analyses) methods were employed to investigate the association of clinical factors and pelvic dose-volume parameters with grade ≥ 3 AHT in patients with cervical cancer. Clinical factors comprised patients’ age, clinical stage, pathologic stage, whether the patient had received chemotherapy in the radiotherapy cycle of interest, and dose-volume dosimetric parameters Vx and Dmean for pelvic bone marrow (BM) and femoral head (FH) structures. Results The incidence of AHT among the included cases was 30.4% (169/556). Chi-square analysis of the clinical factors revealed that whether the patient had received chemotherapy, patient’s age, and pathologic stage had a significant impact on AHT. Univariate analysis showed that the factors associated with AHT were mean dose, V5, V10, V15, V20, and V25 of BM and FH; dosimetric parameters such as V35 of FH had a significant impact on the development of AHT. Multivariate logistic regression analysis identified V15 of pelvic BM as an independent risk factor for AHT (P=0.041), with a threshold value of 84.29% as determined by a receiver operating characteristic (ROC) curve. Conclusion Whether a patient had received chemotherapy in the radiotherapy cycle of interest, and patient’s age and pathologic stage can serve as predictors of AHT. V15 of BM is an independent risk factor for AHT development. Therefore, when formulating a treatment plan, it is crucial to ensure that pelvic V15 remains below 84.29% to effectively reduce the incidence of grade ≥ 3 acute bone marrow depression.
4.Characteristics of the rhizosphere and phyllosphere microbial community of three submerged plants in the dragon-shaped water system of Beijing.
Xiaodong LIU ; Haizhen ZHU ; Minzhi JIANG ; Xuejun WU ; Chengying JIANG ; Shuang-Jiang LIU
Chinese Journal of Biotechnology 2021;37(10):3663-3674
Aquatic plants and the epiphytic microorganisms are important contributors to the purification of constructed wetlands. Taking the dragon-shaped water system of Beijing Olympic Park as a model, this study analyzed the structure and function of the microbial communities reside the sediment, the water body and the rhizosphere and phyllosphere of three submerged plants-Vallisneria natans, Myriophyllum verticillatum, and Potamogeton pectinatus using high-throughput sequencing technology. The results showed that the microbial diversity from the highest to the lowest were samples from sediment, plant rhizosphere, plant phyllosphere and water. The microbial diversity of plant phyllosphere samples were significantly higher than those of the water body. LEfSe analysis showed that different habitats enriched different microbial groups. The sediments mainly enriched anaerobic microbes, while the water body and the phyllosphere of plants mainly enriched aerobic microbes, and the rhizosphere of plants had the both. Functional prediction analysis showed that the abundance of denitrification marker genes in phyllosphere samples was higher than that in samples from rhizosphere, sediment and water body, and the abundance of denitrification marker genes in phyllosphere samples of M. verticillatum and P. pectinatus was higher than that of V. natans. This study could serve as a guidance for the selection of submerged plants and functional microorganisms for constructed wetlands.
Beijing
;
Hydrocharitaceae
;
Microbiota
;
Rhizosphere
;
Water
5.Progress of programmed death-1/programmed death-ligand 1 inhibitors in treatment of triple-negative breast cancer
Xin LI ; Haizhen BAI ; Yuanfei SHAN ; Jiang XUE ; Gang GUO
Cancer Research and Clinic 2021;33(12):957-960
Breast cancer is the malignant tumor with the highest incidence among women in the worldwide. The triple-negative breast cancer (TNBC) has the strongest immunogenicity. Because of the lack of clear molecular targets, TNBC is a subtype of breast cancer with more difficulties in the treatment and poorer prognosis compared to other breast cancer subtypes. Blocking the programmed death-1 (PD-1)/programmed death-ligand 1 (PD-L1) signaling pathway has been a hot spot of research and treatment of tumors. PD-1/PD-L1 inhibitors provide new treatment options for TNBC. This article reviews the research progress of PD-1/PD-L1 inhibitors alone or in combination with other drugs in treatment of TNBC, intending to provide the theoretical basis for basic or clinical studies.
6.The performance of plastic scintillator detector in photon and electron beam
Meijiao WANG ; Kaining YAO ; Sha LI ; Haizhen YUE ; Zhuolun LIU ; Fan JIANG ; Hao WU ; Ruoxi WANG
Chinese Journal of Radiological Medicine and Protection 2021;41(3):205-211
Objective:To investigate the performance of W2 plastic scintillator in megavolt photon and electron beams.Methods:The photon and electron beam energy provided by linear accelerator was used to collect data of the W2 scintillator. The parameters include the electrometer reading stability, W2 dose and dose rate linearity, and angular response. And the dose uncertainty of the W2 correction factors was also investigated.Results:The standard deviation of the electrometer reading stability was between 0.03 and 0.47. The linear regression factors of W2 dose were all 1.0; the maximum deviation of the dose rates was 0.61%. The Cerenkov light radiation correction factor(CLR) for 6 and 10 MV were 0.741 and 0.746, respectively, and the CLR for 6, 9, 12 and 15 MeV were 0.750, 0.753, 0.757 and 0.757, respectively. The maximum deviation of dose uncertainty for 15 MeV was 3.15%.Conclusions:The signal obtained by the blue and green channel was no angular dependence, the same as the high-energy electron beam, which verified that the Cerenkov radiation correction factor has good linearity. W2 plastic scintillator can be applied to non-coplanar radiotherapy dosimetry.
7.A comparative study of dosimetric verification of HalcyonTM treatment plans using Varian Portal Dosimetry and PTW array 1500
Qiaoqiao HU ; Fan JIANG ; Meijiao WANG ; Yibao ZHANG ; Kaining YAO ; Jian GONG ; Hao WU ; Haizhen YUE
Chinese Journal of Radiological Medicine and Protection 2019;39(1):58-62
Objective To compare two pretreatment plan QA methods for HalcyonTM accelerator using Portal Dosimetry (PD),and PTW OCTAVIUS 1500 detector array + Octagonal phantom (Oct 1500)respectively.Methods Parallel measurement-based pretreatment QA using two methods was performed for 22 IMRT/VMAT plans (74 fields) that have been used to treat 20 patients recruited in the Halcyon clinical trial.Several γ 2D comparisons were also applied to provide guidelines for Halcyon planning QA.Results Using Oct1500 method,the γ 2D passing rates for 74 fields in 22 Plans were 95.26±3.59,95.01±3.62 (Local Dose),99.05± 1.35,98.57± 1.96 (Max Dose) respectively.Two-related samples non-parametric tests suggested that the differences between the evaluation criteria were of statistical significance (Z =-7.220,-4.108,P<0.05).For PD method,the γ 2D passing rates were 84.11% ± 1.35% (1 mm/1%),99.07%± 1.35% (2 mm/2%),and 99.86% ± 1.35% (3 mm/3%).Two-related samples non-parametric tests suggested that the differences between evaluation criteria of PD method were statistically significant (Z =-7.475,-7.475,-6.906,P<0.05).For 74 fields and max dose,3 mm/3% evaluation criteria,two-related samples non-parametric tests suggested that the differences between PD and Oct1500 method were statistically significant (Z=-5.072,P<0.05).Conclusions Both methods can be used for Halcyon pretreatment plan QA.PD is superior to Oct1500 with respect to efficiency and spatial resolution-induced verification accuracy.The criteria of 2 mm/2% for PD,and Max Dose/3 mm/3% for Oct1500 was suggested.
8.Knowledge-based semi-automated optimization of intensity-modulated radiotherapy plans using a volume modulated arc therapy-configured model
Yibao ZHANG ; Fan JIANG ; Haizhen YUE ; Qiaoqiao HU ; Jian ZHANG ; Jian GONG ; Hao WU
Chinese Journal of Radiation Oncology 2017;26(2):178-181
Objective To evaluate the feasibility and dosimetric features of a volume modulated arc therapy (VMAT)-configured model in knowledge-based optimization of fixed-field dynamic intensitymodulated radiotherapy (IMRT) plans based on the Varian RapidPlan system.Methods ① A dose-volume histogram prediction model was trained with 81 qualified preoperative VMAT plans for rectal cancer and then statistically verified.② For clinically approved 10 IMRT plans with the same dose prescription,the above model was used to automatically generate new optimization parameters and dynamic muhileaf collimator (MLC) sequences with field geometry and beam energy unchanged.③ In order to rule out the disparities between different versions,a single algorithm was used to calculate the absolute doses of the original and new plans.④ Statistical analyses were performed on dosimetric parameters after comparable target dose coverage was achieved in the two plans by appropriate normalization.Results On the basis of similar target dose homogeneity and coverage,RapidPlan significantly reduced the doses to the urinary bladder (D50% by 9.01 Gy,P =0.000;Dmean by 8.08 Gy,P =0.005) and the femoral head (D50% by 4.20 Gy,P =0.000;Dmean by 3.84 Gy,P=0.005) but significantly elevated the mean total number of monitor units (1211±99 vs.771±79,P=0.000) and the number of fields with multiple MLC carriage groups.The knowledge-based semi-automated optimization caused a significantly larger number of high-dose hotspots but a similar D2% (52.54 vs.52.71 Gy,P=0.239).Conclusions The VMAT model can be used for the knowledge-based semi-automated optimization of IMRT plans to enhance the efficiency and OAR protection.However,the resulting high-dose hotspots need further manual intervention.
9.Absolute dose calibration and output factor simulation for flattened and flattening filter-free Monte Carlo model of 6 MV photon beams
Haizhen YUE ; Yibao ZHANG ; Qiaoqiao HU ; Zhuolun LIU ; Fan JIANG ; Jian GONG ; Hao WU
Chinese Journal of Radiological Medicine and Protection 2017;37(1):29-34
Objective To explore the Monte Carlo calculation methods for the absolute dose calibration and output factor of 6 MV flattening-filter ( FF) and flattening-filter free ( FFF) photon beams based on TrueBeam accelerator .Methods The BEAMnrc code was used to model the LINAC head of FF and FFF modes.The BEAM_up covers the components from the target to the monitor chamber , and BEAM_down includes the structures beneath the chamber , the dose deposit to the monitor chamber contributed by the incidence electrons and scattered particles from the secondary collimators were calculated respectively .The incidence electron-induced dose at certain depths on the central axis were simulated by means of the DOSXYZnrc code .By means of dose calibration equation , the calibration factor for the standard field (10 cm ×10 cm) and the output factors for various fields (1 cm ×1 cm-40 cm ×40 cm) were computed respectively .Results For the 6 MV FF and FFF beams under the standard 10 cm ×10 cm field, 1 MU equals to 7.747 ×1013 ±3.099 ×1011 and 3.248 ×1013 ±1.624 ×1011 electrons to the target , respectively , which deposited 21.53 and 35.01 cGy to the monitor chamber of the virtual accelerator respectively .The difference between the simulated and calculated output factors were 0.72%±1.4%and 0.56%±0.78%for FF and FFF , respectively .Conclusions The model generated and measured output factors agree well , indicating the good accuracy of the dose calculation by the model , which would provides basis for further clinical dosimetric studies .
10.The model training of knowledge-based radiotherapy treatment planning and its preliminary application
Fan JIANG ; Yibao ZHANG ; Haizhen YUE ; Qiaoqiao HU ; Hao WU
Chinese Journal of Radiation Oncology 2016;25(11):1223-1227
Objective Knowledge?based radiotherapy ( KBRT ) can reduce the plan quality variability induced by different experiences between physicians and improve the quality of treatment plans. Methods The Varian Rapid Plan system was used to train a dose?volume histogram ( DVH) prediction model. The obtained model was preliminarily applied to semi?automatic design of the preoperative treatment plans for rectal cancer. Eighty high?quality volumetric modulated arc therapy plans were imported into the model training set of the Rapid Plan system. The structures of the plans were matched to the corresponding labels and codes as listed in the library. The training started after the verification of prescription. The residual plots,regression curves,geometric plots for organ at risk ( OAR) ,in?field DVH plots,and model training logs were examined. After removal of the mismatch, the original plans were assessed to rule out outliers and influential data points. More similar plans may be added for another round of training. Ten KBRT plans were designed using the final model and compared with the clinical plans. Results For the two major OARs,the femoral head and bladder,the average goodness of fit of the principal component were 0?999 415/1.0 and 0?999 963/1.0 for the DVH model,and 0?999 651/1.0 and 0?999 945/1.0 for geometry?based expected dose model,respectively. In all the plans, 11 had Cook ’ s distance values exceeding the tolerance and 4 had studentized residual values exceeding the tolerance. The outliers were all kept in the training set to generalize the scope of the model. The 10 KBRT plans had significantly improved homogeneity indices for PGTV and PTV than the original plans (P=0?00,0?04).The 10 KBRT plans also had significantly reduced D50% to the femoral head and bladder as well as significantly reduced mean doses to the bladder than the original plans (P=0?042,0?000,0?005). Conclusions In this study,the Rapid Plan system is used to train a KBRT model for design of preoperative radiotherapy plans for rectal cancer. The results of preliminary application meet the clinical requirements.

Result Analysis
Print
Save
E-mail