1.Establishment and stress analysis of a finite element model for adolescent cervical disc herniation
Yuxin ZHAO ; Liang LIANG ; Feng JIN ; Yangyang XU ; Zhijie KANG ; Yuan FANG ; Yujie HE ; Xing WANG ; Haiyan WANG ; Xiaohe LI
Chinese Journal of Tissue Engineering Research 2025;29(3):448-454
BACKGROUND:Cervical disc herniation can cause pain in the neck and shoulder area,as well as radiating pain in the upper limbs.The incidence rate is increasing year by year and tends to affect younger individuals.Fully understanding the biomechanical characteristics of the cervical spine in adolescents is of great significance for preventing and delaying the onset of cervical disc herniation in this age group. OBJECTIVE:To reconstruct cervical spine models for both healthy adolescents and adolescent patients with cervical disc herniation utilizing finite element analysis techniques,to analyze the motion range of the C1-T1 cervical vertebrae as well as the biomechanical characteristics of the annulus fibrosus,nucleus pulposus,endplates,and the cartilage of the small joints. METHODS:A normal adolescent's cervical spine and an adolescent patient with cervical disc herniation were selected in this study.The continuous scan cervical spine CT raw image data were imported into Mimics 21.0 in DICOM format.The C1-T1 vertebrae were reconstructed separately.Subsequently,the established models were imported into the 3-Matic software for disc reconstruction.The perfected models were then imported into Hypermesh software for meshing of the vertebrae,nucleus pulposus,annulus fibrosus,and ligaments,creating valid geometric models.After assigning material properties,the final models were imported into ABAQUS software to observe the joint motion range of the C1-C7 cervical vertebrae segments under different conditions,and to analyze the biomechanical characteristics of the annulus fibrosus,nucleus pulposus,endplates,and small joint cartilage of each cervical spine segment. RESULTS AND CONCLUSION:(1)In six different conditions,the joint motion range of the C1 vertebra in the cervical spine models of both normal adolescent and adolescent patient with cervical disc herniation was higher than that of the other vertebrae.Additionally,the joint motion range of each cervical spine segment in normal adolescent was greater than that in adolescent patient with cervical disc herniation.(2)In the cervical spine model of normal adolescent,the maximum stress values in the annulus fibrosus and nucleus pulposus were found on the left side during C2-3 flexion conditions(0.43 MPa and 0.17 MPa,respectively).In the cervical spine model of adolescent patient with cervical disc herniation,the maximum stress values were found on the left side during C7-T1 flexion conditions(0.54 MPa and 0.18 MPa,respectively).(3)In the cervical spine model of normal adolescent,the maximum stress value on the endplate was found on the left side of the upper endplate of C3 during flexion conditions(1.46 MPa).In the model of adolescent patient with cervical disc herniation,the maximum stress value on the endplate was found on the left side of the lower endplate of C7 during flexion conditions(1.32 MPa).(4)In the cervical spine model of normal adolescent,the maximum stress value in the small joint cartilage was found in the C2-3 left rotation conditions(0.98 MPa).In adolescent patient with cervical disc herniation,the stress in the small joint cartilage significantly increased under different conditions,especially in C1-2,with the maximum stress found during left flexion(3.50 MPa).(5)It is concluded that compared to normal adolescent,adolescent patient with cervical disc herniation exhibits altered cervical curvature and a decrease in overall joint motion range in the cervical spine.In adolescent with cervical disc herniation,there is a significant increase in stress on the annulus fibrosus,nucleus pulposus,and endplates in the C7-T1 segment.The stress on the left articular cartilage of the C1-2 is notable.Abnormal cervical curvature may be the primary factor causing these stress changes.
2.Automatic acquisition and analytic procedure of acupuncture manipulation based on optical navigation.
Changshuai ZHANG ; Zihao FENG ; Weichao CHANG ; Weigang MA ; Yongjian WU ; Haiming LI ; Xingfang PAN ; Haiyan REN ; Yangyang LIU ; Zhaoshui HE ; Wenjun TAN
Chinese Acupuncture & Moxibustion 2025;45(10):1383-1390
This paper presents an automatic acquisition and analytic procedure of acupuncture manipulation based on optical navigation, aiming at solving the shortcomings of existing acquisition methods of acupuncture manipulation. An acquisition holder installed at the handle tail of filiform needle was designed to display the movement trajectory of the needle during acupuncture delivery by collecting the movement trajectory of holder. The 3-month old male Bama miniature pig was selected as the experimental subject, and 6 points, "Bojian" "Qiangfeng" "Housanli" "Xiaokua" "Huiyang" (BL35) and "Baihui" (GV20), were selected during acupuncture manipulation. The optical navigation system was used to collect the real-time data, and these data were per-processed and analyzed using mean filtering and Fourier transform. The acupuncture procedure was divided into 3 stages, inserting, lifting-thrusting, and twisting. The results showed that the accuracy was 96.3% at lifting-thrusting stage, and that was 100.0% at twisting stage. The decomposition effect of the entire procedure was satisfactory. This study provides a new approach to the quantitative analysis of acupuncture manipulation. In the future, it needs to further optimize the algorithm and expand the sample size so as to improve the accuracy of this analytic technique.
Acupuncture Therapy/methods*
;
Male
;
Animals
;
Swine
;
Acupuncture Points
;
Humans
;
Swine, Miniature
;
Needles
3.Extracellular vesicles as a multicomponent biomarker platform for sepsis.
Feng CHEN ; Zhe GUO ; Xuesong WANG ; Haiyan LIAO ; Ziyi WANG ; Zhiqing CHEN ; Zhong WANG
Chinese Medical Journal 2025;138(21):2838-2840
4.Application value of gracilis muscle flap in repairing urethral perineal fistula after Miles operation.
Ji ZHU ; Ying-Long SA ; Zhe-Wei ZHANG ; Hui-Feng WU
National Journal of Andrology 2025;31(7):625-629
OBJECTIVE:
To investigate the clinical effect of transposition of gracilis muscle flap in repairing urethral perineal fistula after Miles operation.
METHODS:
The clinical data of 3 patients with urethral perineal fistula treated in the Second Affiliated Hospital of Zhejiang University from September 2023 to November 2024 were analyzed retrospectively. All patients were male, aged from 59 to 68 years (mean 63 years). All patients underwent Miles operation because of low rectal cancer. Urethral perineal fistula occurred after 2 months to 13 years of the operation. The underlying comorbidities included diabetes (2/3), preoperative chemoradiotherapy (1/3), and chemotherapy alone (1/3). The endourethral fistula was located in the apical and membranous part of the prostate, with a diameter of 1.5-2.0 cm and a mean of 1.7 cm. Suprapubic cystostomy was performed one month before operation. In all 3 cases, perineal inverted "Y" incision was taken under general anesthesia to expose urethral fistula, cut off necrotic tissue and suture urethral fistula. The gracilis muscle of the right thigh was taken and turned through the perineal subcutaneous tunnel. and 6 stitches were suture at the urethral fistula.
RESULTS:
The operations of all 3 patients were completed successfully. The follow-up period ranged from 2 months to 12 months, with an average of 8 months. There was no case of urinary incontinence after removal of catheter 3 weeks after operation. In two patients, urethrography was reviewed 1 month after surgery to show no fistula residue and urethral stenosis, and the fistula was removed. In one patient with a history of radiotherapy, urethrography was reviewed 1 month after surgery to show a small amount of contrast overflow around the urethra, and urethrography was reviewed again 3 months after surgery to show no contrast overflow around the urethra. All the 3 patients had no disturbance of movement of the right lower limb, and the pain of different degrees of thigh incision was acceptable and basically relieved half a month after operation.
CONCLUSION
Gracilis muscle flap is one of the effective methods for repairing urethral perineal fistula after Miles operation,which has a precise surgical result and few complications.
Humans
;
Male
;
Middle Aged
;
Aged
;
Gracilis Muscle/transplantation*
;
Urinary Fistula/surgery*
;
Retrospective Studies
;
Surgical Flaps
;
Perineum/surgery*
;
Rectal Neoplasms/surgery*
;
Postoperative Complications/surgery*
;
Urethral Diseases/surgery*
;
Urethra/surgery*
5.A cross-sectional study on the pain caused by hyaluronic acid cosmetic injections
Lishuai SHI ; Lili QI ; Jun ZHANG ; Tao WANG ; Guobao WANG ; Feng ZHOU ; Lunli GONG ; Qiuni GAO ; Xiaoqing YAN ; Meng FAN ; Haiyan CUI
Chinese Journal of Plastic Surgery 2024;40(1):326-333
Objective:To learn about physicians’ concepts and commonly employed method in hyaluronic acid injection and provide reference data for the standardization of pain management.Methods:This study was a cross-sectional study. Convenient sampling method was used to distribute questionnaires to cosmetic injectors and patients experienced with hyaluronic acid injections to collect data on their views of pain associated with hyaluronic acid injections. The physician portion was collected offline from June 15 to July 20, 2022, and the patient portion was collected from November 14, 2022, to December 6, 2022, via the Questionnaire Star platform. The physician questionnaire consisted of 17 questions, question types included single choice, multiple choice and essay questions. The patient questionnaire consisted of 6 questions, question types included single choice and multiple choice. Relevant data were analyzed using SPSS 22.0 software for descriptive statistics, and data were presented in the form of cases and percentages (%).Results:Sixty-two physician questionnaires and 123 patient questionnaires were collected. 42 (67.74%) physicians observed from their daily practice that more than 50% of their patients were very concerned about pain during injection; 101 (82.11%) patients scored ≥5 out of 10 for concern about impending pain prior to hyaluronic acid filler injection. At the time of treatment, 48 (77.42%) physicians advised patients to choose a lidocaine-containing hyaluronic acid filler for reasons including a significant reduction in injection pain (53 cases, 85.48%) and patient comfort with the treatment experience (59 cases, 95.16%). 60 (48.78%) patients were willing to choose an anesthesia-containing product at the time of injection, but the price of the anesthesia-containing product influenced the patient’ s choice (55 cases 44.72%) .Conclusions:Pain from cosmetic injectable treatments is an important issue to both physicians and patients. Lidocaine-containing hyaluronic acid is recognized by physicians and patients for its analgesic effect and high safety profile. There is no perfect solution for pain in cosmetic injection treatment, and multidisciplinary collaboration may be needed to solve the problem.
6.A cross-sectional study on the pain caused by hyaluronic acid cosmetic injections
Lishuai SHI ; Lili QI ; Jun ZHANG ; Tao WANG ; Guobao WANG ; Feng ZHOU ; Lunli GONG ; Qiuni GAO ; Xiaoqing YAN ; Meng FAN ; Haiyan CUI
Chinese Journal of Plastic Surgery 2024;40(4):428-435
Objective:To learn about physicians’ concepts and commonly employed method in hyaluronic acid injection and provide reference data for the standardization of pain management.Methods:This study was a cross-sectional study. Convenient sampling method was used to distribute questionnaires to cosmetic injectors from plastic surgery department of public hospitals or medical beauty institutions and patients experienced with hyaluronic acid injections to collect data on their views of pain associated with hyaluronic acid injections. The physician portion was collected offline from June 15 to July 20, 2022, and the patient portion was collected from November 14 to December 6, 2022, via the Questionnaire Star platform. The physician questionnaire consisted of 17 questions, question types included single choice, multiple choice and essay questions. The patient questionnaire consisted of 6 questions, question types included single choice and multiple choice. Relevant data were analyzed using SPSS 22.0 software for descriptive statistics, and data were presented in the form of cases(%).Results:Sixty-two physician questionnaires and 123 patient questionnaires were collected. 42 (67.74%) physicians observed from their daily practice that more than 50% of their patients were very concerned about pain during injection; 101 (82.11%) patients scored ≥5 out of 10 for concern about impending pain prior to hyaluronic acid filler injection. At the time of treatment, 48 (77.42%) physicians advised patients to choose a lidocaine-containing hyaluronic acid filler for reasons including a significant reduction in injection pain (53 cases, 85.48%) and patient comfort with the treatment experience (59 cases, 95.16%). 60 (48.78%) patients were willing to choose an anesthesia-containing product at the time of injection, but the price of the anesthesia-containing product influenced the patient’s choice (55 cases, 44.72%).Conclusion:Pain from cosmetic injectable treatments is an important issue to both physicians and patients. Lidocaine-containing hyaluronic acid is recognized by physicians and patients for its analgesic effect and high safety profile. There is no perfect solution for pain in cosmetic injection treatment, and multidisciplinary collaboration may be needed to solve the problem.
7.A cross-sectional study on the pain caused by hyaluronic acid cosmetic injections
Lishuai SHI ; Lili QI ; Jun ZHANG ; Tao WANG ; Guobao WANG ; Feng ZHOU ; Lunli GONG ; Qiuni GAO ; Xiaoqing YAN ; Meng FAN ; Haiyan CUI
Chinese Journal of Plastic Surgery 2024;40(1):326-333
Objective:To learn about physicians’ concepts and commonly employed method in hyaluronic acid injection and provide reference data for the standardization of pain management.Methods:This study was a cross-sectional study. Convenient sampling method was used to distribute questionnaires to cosmetic injectors and patients experienced with hyaluronic acid injections to collect data on their views of pain associated with hyaluronic acid injections. The physician portion was collected offline from June 15 to July 20, 2022, and the patient portion was collected from November 14, 2022, to December 6, 2022, via the Questionnaire Star platform. The physician questionnaire consisted of 17 questions, question types included single choice, multiple choice and essay questions. The patient questionnaire consisted of 6 questions, question types included single choice and multiple choice. Relevant data were analyzed using SPSS 22.0 software for descriptive statistics, and data were presented in the form of cases and percentages (%).Results:Sixty-two physician questionnaires and 123 patient questionnaires were collected. 42 (67.74%) physicians observed from their daily practice that more than 50% of their patients were very concerned about pain during injection; 101 (82.11%) patients scored ≥5 out of 10 for concern about impending pain prior to hyaluronic acid filler injection. At the time of treatment, 48 (77.42%) physicians advised patients to choose a lidocaine-containing hyaluronic acid filler for reasons including a significant reduction in injection pain (53 cases, 85.48%) and patient comfort with the treatment experience (59 cases, 95.16%). 60 (48.78%) patients were willing to choose an anesthesia-containing product at the time of injection, but the price of the anesthesia-containing product influenced the patient’ s choice (55 cases 44.72%) .Conclusions:Pain from cosmetic injectable treatments is an important issue to both physicians and patients. Lidocaine-containing hyaluronic acid is recognized by physicians and patients for its analgesic effect and high safety profile. There is no perfect solution for pain in cosmetic injection treatment, and multidisciplinary collaboration may be needed to solve the problem.
8.A cross-sectional study on the pain caused by hyaluronic acid cosmetic injections
Lishuai SHI ; Lili QI ; Jun ZHANG ; Tao WANG ; Guobao WANG ; Feng ZHOU ; Lunli GONG ; Qiuni GAO ; Xiaoqing YAN ; Meng FAN ; Haiyan CUI
Chinese Journal of Plastic Surgery 2024;40(4):428-435
Objective:To learn about physicians’ concepts and commonly employed method in hyaluronic acid injection and provide reference data for the standardization of pain management.Methods:This study was a cross-sectional study. Convenient sampling method was used to distribute questionnaires to cosmetic injectors from plastic surgery department of public hospitals or medical beauty institutions and patients experienced with hyaluronic acid injections to collect data on their views of pain associated with hyaluronic acid injections. The physician portion was collected offline from June 15 to July 20, 2022, and the patient portion was collected from November 14 to December 6, 2022, via the Questionnaire Star platform. The physician questionnaire consisted of 17 questions, question types included single choice, multiple choice and essay questions. The patient questionnaire consisted of 6 questions, question types included single choice and multiple choice. Relevant data were analyzed using SPSS 22.0 software for descriptive statistics, and data were presented in the form of cases(%).Results:Sixty-two physician questionnaires and 123 patient questionnaires were collected. 42 (67.74%) physicians observed from their daily practice that more than 50% of their patients were very concerned about pain during injection; 101 (82.11%) patients scored ≥5 out of 10 for concern about impending pain prior to hyaluronic acid filler injection. At the time of treatment, 48 (77.42%) physicians advised patients to choose a lidocaine-containing hyaluronic acid filler for reasons including a significant reduction in injection pain (53 cases, 85.48%) and patient comfort with the treatment experience (59 cases, 95.16%). 60 (48.78%) patients were willing to choose an anesthesia-containing product at the time of injection, but the price of the anesthesia-containing product influenced the patient’s choice (55 cases, 44.72%).Conclusion:Pain from cosmetic injectable treatments is an important issue to both physicians and patients. Lidocaine-containing hyaluronic acid is recognized by physicians and patients for its analgesic effect and high safety profile. There is no perfect solution for pain in cosmetic injection treatment, and multidisciplinary collaboration may be needed to solve the problem.
9.Finite element model establishment and stress analysis of lumbar-sacral intervertebral disc in ankylosing spondylitis
Zhijie KANG ; Zhenhua CAO ; Yangyang XU ; Yunfeng ZHANG ; Feng JIN ; Baoke SU ; Lidong WANG ; Ling TONG ; Qinghua LIU ; Yuan FANG ; Lirong SHA ; Liang LIANG ; Mengmeng LI ; Yifei DU ; Lin LIN ; Haiyan WANG ; Xiaohe LI ; Zhijun LI
Chinese Journal of Tissue Engineering Research 2024;28(6):840-846
BACKGROUND:Ankylosing spondylitis is a chronic inflammatory disease with chronic rheumatic immunity.Soft tissue ossification and fusion and spinal stiffness can cause biomechanical changes. OBJECTIVE:To reconstruct the lumbar-sacral intervertebral disc in ankylosing spondylitis patients with lumbar kyphosis by finite element analysis,and to study the range of motion of each segment of T11-S1 and the biomechanical characteristics of annulus fibrosus and nucleus pulposus. METHODS:The imaging data were obtained from an ankylosing spondylitis patient with lumbar kyphosis.The original CT image data of continuously scanned spine were imported into Mimics 21.0 in DICOM format,and T11-S1 was reconstructed respectively.The established model was imported into 3-Matic software in the format of"Stl"to reconstruct the intervertebral disc,and the fibrous intervertebral disc model was obtained.The improved model was further imported into Hypermesh software,and the vertebra,nucleus pulposus,annulus fibrosus and ligament were mesh-divided.After the material properties were given,the model was imported into ABAQUS software to observe the range of motion of each vertebral body in seven different working conditions of T11-S1,and analyze the biomechanical characteristics of each segment of annulus fibrosus and nucleus pulposus. RESULTS AND CONCLUSION:(1)The range of motion of L1 vertebrae was higher than that of other vertebrae under six different working conditions:extension,forward flexion,rotation(left and right),and lateral flexion(left and right).The maximum range of motion was 2.18° during L1 vertebral flexion,and the minimum range of motion was 0.12° during L5 vertebral extension.(2)The annular fiber flexion at L2-L3 segments was greater than the extension(P<0.05),and the annular fiber flexion at L3-L4 and L4-L5 segments was less than the extension(P<0.05).The left rotation of L1-L2 annular fibers was greater than the right rotation(P<0.05).The left flexion of the annulus was greater than the right flexion in L1-L2,L2-L3,L3-L4,L4-L5 and L5-S1 segments(P<0.05).(3)The nucleus pulposus stresses of T11-L12,L1-L2,L2-L3,L3-L4 and L4-L5 segments in forward flexion were greater than in extension(P<0.05).The left rotation of T12-L1 and L3-L4 segments was smaller than the right rotation(P<0.05),and that of T11-T12,L1-L2,and L2-L3 segments was larger than the right rotation(P<0.05).The left flexion was larger than the right flexion in the T11-S1 segment.(4)It is concluded that in ankylosing spondylitis patients with lumbar kyphosis,the minimum range of motion of the vertebral body is located at the L5 vertebral body in extension.To prevent fractures,it is recommended to avoid exercise in the extension position.During the onset of lumbar kyphosis in patients with ankylosing spondylitis,the maximum stress of the annulus fibrosus and nucleus pulposus is located in the L1-L2 segment,which is fixed and will not alter with the change of body position.The late surgical treatment and correction of deformity should focus on releasing the pressure of the annulus fibrosus and nucleus pulposus in this segment to avoid the rupture of the annulus fibrosus and the injury of the nucleus pulposus.
10.Biomechanical features of posterior"Y"osteotomy and fixation in treatment of ankylosing spondylitis based on finite element simulation analysis
Le ZHANG ; Zhenhua CAO ; Yunfeng ZHANG ; Yangyang XU ; Feng JIN ; Baoke SU ; Lidong WANG ; Xing WANG ; Ling TONG ; Qinghua LIU ; Yuan FANG ; Lirong SHA ; Haiyan WANG ; Xiaohe LI ; Zhijun LI
Chinese Journal of Tissue Engineering Research 2024;28(12):1842-1848
BACKGROUND:Ankylosing spondylitis is a progressive inflammation of spinal stiffness deformity caused by tissue ossification and fibrosis.The posture of ankylosing spondylitis patients is abnormal and their activities are limited that minor injuries can lead to thoracolumbar fractures.Traditional medical image observation limits doctors'preoperative decision planning and postoperative disease prevention for ankylosing spondylitis treatment. OBJECTIVE:Based on the spinal model of ankylosing spondylitis patients before and after posterior spinal cancellous ossification osteotomy("Y"osteotomy for short),to explore the biomechanical changes of"Y"osteotomy and fixation in the treatment of ankylosing spondylitis. METHODS:Based on the preoperative and postoperative CT images of an ankylosing spondylitis patient who went to the Second Affiliated Hospital of Inner Mongolia Medical University,a three-dimensional spine model(T11-S1)before and after"Y"osteotomy(L3 osteotomy)was reconstructed in Mimics 19.0 software.A 7.5 Nm torque was applied to the top of T11 vertebral body to simulate the movement of the spine under six conditions:flexion,extension,left bending,right bending,left rotation and right rotation.Finally,the range of motion of each vertebral body,the stress of each intervertebral disc,and the stress of the screw rod system were simulated. RESULTS AND CONCLUSION:(1)After"Y"type osteotomy and posterior fixation,the range of motion of all vertebrae in the spine decreased,and the loss rate of upper vertebrae was large(L1:77.95%).(2)The maximum stress of the spinal intervertebral disc before operation occurred at the L1-L2 segment(0.55 MPa),and the maximum stress of the spinal intervertebral disc after operation occurred at the T11-T12 segment(0.50 MPa),and the stress of intervertebral disc below T12 was far less than that before operation.(3)The maximum stress of the screw rod system(166.67 MPa)occurred in the upper and middle segments of the rod body and the root of the pedicle screw.(4)In conclusion,the"Y"type posterior fixation operation enhances the stability of the spine and reduces the range of motion of the spine.The vertebral body decompression of the fixed segment is great and the stress-shielding phenomenon of the lower vertebral body is significant.The stiffness of the rod body and the stress concentration area of the pedicle screw should be strengthened to avoid the fracture of the rod caused by stress fatigue.

Result Analysis
Print
Save
E-mail