1.Implanted cortical electrical stimulation and the expressions of Nissl bodies and growth-associated protein 43 In the brain after ischemic injury
Sichao ZHOU ; Tao LI ; Haihan ZHOU ; Xuan CHENG ; Qian ZHANG ; Jie TAN ; Chengyan LI ; Yanwen DUAN
Chinese Journal of Physical Medicine and Rehabilitation 2012;34(6):421-425
Objective To investigate the effect of implanted cortical electrical stimulation (CES) on the expression of Nissl bodies and growth-associated protein 43 (GAP-43) in the brain after ischemic injury,and its mechanism.Methods Models of middle cerebral artery occlusion (MCAO) were established in 23 male Sprague-Dawley rats.They were randomly divided into a CES group (CES,n=13) and a no stimulation group (NS,n=10) and electrical stimulators were implanted in both groups.CES was applied for 14 d in the CES group but not in the NS group.The expression of Nissl bodies and GAP-43 around the infarct were quantified using version 6.0 of the ImagePro Plus system.Results In the CES group the Nissl bodies had a deep color,and their percentage of area was higher than that in the NS group.The GAP-43 positive expression area also had a relatively deep color,and the average percentage of positive expression area was also higher than that in the NS group.Conclusions CES can enhance the expression of Nissl bodies and GAP-43 after cerebral infarction.This suggests that CES can promote axon growth and the formation of new neural circuits.
2.The using status quo and analysis of POCT glucose meter
Miao WANG ; Ranyun ZHOU ; Xinglong YANG ; Wenxia CHEN ; Qingling GUO ; Lijun ZENG ; Qianlin YANG ; Fan JIA ; Xin WANG ; Haihan WU ; Shiping SONG
Chinese Journal of Laboratory Medicine 2016;39(8):643-645
Objective To investigate the problems during using, standard and quality management of the POCT glucose meters in hospital, to analyze the solutions, and to provide reference data for improving the test level of POCT in hospital.Methods The amount, brand and application of portable glucose meters in the hospital were obtained by 3 rounds of surveillance from May to July in 2013.All of those glucose meters were taken part in external quality assessment of Clinical Laboratory Center of National Health and Family Planning Commission.The test results of those glucose meters were compared with that of automatic biochemical analyzer, the comparison results were then analyzed.Results The POCT glucose meters possessed 5 brands in our hospital, and the amount and type of glucose meters in some clinical departments were often changed.When 4 brands which were detected as quality control samples by ministry of health, the accuracy of detection results of 3 concentration of brand Ⅲ were substandard, the CV% of two levels were 11.9%and 10.1%respectively, the remaining 3 brands were in line with the requirements.The qualified percentages of 3 times of comparison were 85.0%, 92.0%and 97.4%.Conclusions The hospital should select the brand of portable glucose meters reasonably, correct use of glucose meters, and it is very necessary to build indoor and interstitial quality evaluation system, at the same time, suggesting the hospital to establish the POCT quality management team, to carry out the instrument comparison periodically, so to guarantee the accurate, reliable results of POCT in hospital.