1.Combination of plate screw and Steinmann pin in repair of comminuted calcaneal intra-articular and posterosuperior fractures
Guangfeng LI ; Xianmin WU ; Sicheng WANG ; Guoqing YANG ; Youzhong ZHANG ; Zhonghua CAO ; Guoyun HE ; Zhifeng YIN ; Xiaoyu YANG ; Xin ZHANG ; Yong PENG
Chinese Journal of Tissue Engineering Research 2014;(35):5627-5632
BACKGROUND:The therapeutic regimen of intraarticular calcaneal comminuted fractures commonly selects plate and screw fixation. However, for case of posterosuperior calcaneal fracture, the weakness of achil es tendon stretch and plate screw fixation results in difficulty or maintenance of reduction. OBJECTIVE:To investigate the therapeutic effects of open reduction and internal fixation with steel screw and Steinmann pins for comminuted calcaneal intra-articular and posterosuperior fractures. METHODS:From December 2009 to December 2013, forty patients with fractures of comminuted calcaneal posterosuperior fractures were randomly divided into two groups. In the control group, patients were treated by open reduction and internal fixation by plate screw only. In the experimental group, patients were treated by open reduction and internal fixation by combination of plate screw and Steinmann pin. The Gissane and Bohler angles of the calcaneus were measured from lateral radiograph before and 4 weeks after surgery, and the MARYLAND score was assessed at the last fol ow-up. Gissane and Bohler angle and MARYLAND score were compared in each group and among different groups. RESULTS AND CONCLUSION:Al patients were fol owed up for 9-23 months. BOHLER and GISSANE angles were significantly bigger at 4 weeks after surgery compared with pre-treatment in both groups (P<0.05). BOHLER and GISSANE angles were significantly bigger in the experimental group than in the control group at 4 weeks after surgery (P<0.05). During final fol ow-up, the average score by MARYLAND Foot Score was 78 in the experimental group and 67 in control group, with their excellent and good rate of 80%and 73%. The excellent and good rate was significantly higher in the experimental group than in the control group (P<0.05). These data indicated that open reduction and internal fixation with combination of plate screw and Steinmann pin has better efficacy in treatment of the comminuted calcaneal intra-articular and posterosuperior fractures compared with plate and screw fixation alone. Their fixation is firm. Functional exercise can be performed earlier. Postoperative recovery of function of the affected limbs is better than plate and screw fixation alone.
2.USPIO-enhanced MRI for lymph-node metastases from abdominal and pelvic malignancies: Meta-analysis
Lulu XU ; Jian SHU ; Guoyun HE ; Yan HU ; Yu CAI
Chinese Journal of Medical Imaging Technology 2018;34(2):254-259
Objective To investigate value of ultrasmall superparamagnetic iron oxide (USPIO)-enhanced MRI in diagnosis of lymph node metastasis from abdominal and pelvic malignancies with Meta-analysis.Methods A systematic search was conducted in PubMed,Embase,Cochrane Library,Wanfang,VIP and CNKI databases.The literature were screened according to inclusion and exclusion criteria,and four tabular data were extracted.With Meta Disc version 1.4 and STATA 11.0 software,statistical analysis was performed and heterogeneity of the included articles was tested.Based on the result of heterogeneity test,proper effect model was selected to calculate the pooled sensitivity and specificity.Summary receiver operating characteristics curve was obtained,and the area under curve (AUC) was calculated.Results Totally 20 English literature were enrolled,including 1 211 patients and 3 583 lymph nodes.The pooled sensitivity and specificity for USPIO-enhanced MRI in diagnosis of lymph node metastasis was 0.89 (95%CI [0.86,0.91]) and 0.96 (95 %CI [0.95,0.96]),and AUC was 0.98,respectively.Regression analysis revealed that the heterogeneity may result from the location of tumors,and subgroup analysis showed that pooled sensitivity in diagnosis of lymph node metastasis in abdominal malignancies was good.Conclusion USPIO-enhanced MRI has good diagnostic efficacy in diagnosis of lymph node metastasis from abdominal and pelvic malignancies.
3.Comparison of short-term effects of arthroscopic and open reduction and internal fixation with Herbert screws in treatment of radial head fractures
Guangfeng LI ; Zhifeng YIN ; Hao DU ; Yong PENG ; Zhonghua CAO ; Wang LI ; Wenru ZHANG ; Guoyun HE ; Youzhong ZHANG ; Sicheng WANG
Chinese Journal of Trauma 2021;37(3):229-235
Objective:To compare the short-term clinical effect of arthroscopic and open reduction and internal fixation with Herbert screws in treatment of Mason type II radial head fractures.Methods:A retrospective case-control study was conducted to analyze the clinical data of 38 patients with unilateral radial head fractures (Mason type II) admitted to Shanghai Zhongye Hospital from January 2017 to December 2018, including 22 males and 16 females, aged from 20 to 65 years [(37.4±12.6)years]. Twenty patients were treated by arthroscopic reduction and internal fixation with Herbert screw (Group A), and eighteen by open reduction and internal fixation with Herbert screw (Group B). The operation time and fracture healing time were recorded. The visual analogue scale (VAS), elbow flexion and extension range, forearm rotation range and Mayo elbow function score were compared between the two groups before and at 1, 3, 6, and 12 months after operation. The results of Mayo elbow performance score (MEPS) and upper limb function assessment using the disabilites of the arm, shoulder, and hand (DASH) score were compared between the two groups. Complications including screw breakage or fracture displacement were also evaluated.Results:All patients were followed up for 12-14 months [(12.3±2.3)months]. There was no significant difference in operation time between the two groups ( P>0.05). The fracture healing time was (8.9±0.6)weeks in Group A and (8.7±0.6)weeks in Group B ( P>0.05). There was no significant difference in VAS between the two groups before operation ( P>0.05). The VAS was (4.8±0.5)points at 1 month after operation in Group A, lower than (6.0±0.7)points in Group B ( P<0.05). There was no significant difference in VAS between Group A and Group B at 3, 6, and 12 months after operation ( P>0.05). There was no significant difference in elbow flexion and extension range between the two groups before operation ( P>0.05). The elbow flexion and extension range in Group A was (110.4±3.8)° and (137.1±4.0)° at 1, 3 months after operation, which was significant greater than (90.6±4.7)° and (125.1±3.5)° in Group B ( P<0.05). There was no significant difference in elbow flexion and extension range between the two groups at 6 and 12 months after operation ( P>0.05). There was no significant difference in the range of forearm rotation between the two groups before operation ( P>0.05). The range of forearm rotation in Group A was (107.1±2.8)° and (138.1±2.9)° at 1, 3 months after operation, significantly greater than (95.5±3.9)°, (121.5±3.0)° in Group B ( P<0.05). There was no significant difference in forearm rotation range between the two groups at 6 and 12 months after surgery ( P>0.05). There was no significant difference in MEPS between the two groups before operation ( P>0.05). The MEPS in Group A was (50.4±3.8)points at 1 month after operation, higher than (40.6±4.7)points in Group B ( P<0.05). There was no significant difference in MEPS between the two groups at 3, 6, and 12 months after operation ( P>0.05). There was no significant difference in DASH score between the two groups before operation ( P>0.05). The DASH score was (57.1±2.8)points at 1 month after surgery in Group A, higher than (42.5±3.9)points in Group B ( P<0.05). The DASH score was not significantly different between the two groups at 3, 6, and 12 months after operation ( P>0.05). There was no screw loosening or fracture after operation, and one patient in each group had fracture displacement ( P>0.05). Conclusion:For Mason type II radial head fractures, arthroscopic Herbert screw fixation has the advantages of less trauma, less pain and faster functional recovery of the affected limb compared with open reduction and Herbert screw fixation.
4.Antibacterial properties of silver nanoparticle-coated stainless steel prepared via active screen plasma surface modification in vitro
Zhaofei WANG ; Guoyun HE ; Fangcan TIAN ; Guangfeng LI ; Zhonghua CAO ; Xiangfei LIU
Chinese Journal of Tissue Engineering Research 2024;28(22):3464-3471
BACKGROUND:Most of the silver coating materials prepared using active screen plasma technology in the past do not involve the nanotechnology field.The formed silver coating is in a"thin film"form,which is coated on the surface of the substrate,and the distribution of silver particles on the surface is uneven.Its long-term antibacterial ability is challenged. OBJECTIVE:To prepare nano silver coatings capable of being"buried"within stainless steel(SS)substrates using active screen plasma surface modification(ASPSM)and to observe antibacterial activity. METHODS:The nano-silver coating was prepared by ASPSM technique on stainless steel substrate.Three groups of coating samples were prepared by adjusting the bombardment time(1,2,and 4 hours),which were denoted as 1 h-Ag-ASPSM@SS,2 h-Ag-ASPSM@SS and 4 h-Ag-ASPSM@SS,respectively.The antibacterial activity of the coatings was analyzed by antibacterial ring test and Gram staining.The antibiotic coating samples of gentamicin combined with vancomycin were prepared by using stainless steel as substrate and were recorded as ACNs.Stainless steel,2 h-Ag-ASPSM@SS,and ACNs were inserted into Staphylococcus aureus or Pseudomonas aeruginosa suspension,respectively.The long-acting(84 days)antibacterial activity of the samples was analyzed by coating plate method.Bone marrow mesenchymal stem cells were co-cultured with stainless steel,2 h-Ag-ASPSM@SS,and ACNs,respectively.CCK-8 assay,dead/alive staining,and lactate dehydrogenase activity of cell supernatant were detected.Stainless steel,2 h-Ag-ASPSM@SS,and ACNs were taken after continuous exposure to Staphylococcus aureus suspension for 12 weeks.The amount of residual viable bacteria on the surface of the material was evaluated by spread plate method.Vancomycin drug sensitive disk method was used to evaluate the resistance of residual live bacteria on the surface of materials. RESULTS AND CONCLUSION:(1)With increasing bombardment time,the diameter of nano silver on the sample surface and the silver content in the coating gradually increased.Among them,the 2 h-Ag-ASPSM@SS exhibited the highest surface silver content while forming uniformly spherical nanoparticles.(2)Antibacterial ring test and Gram staining results demonstrated that compared with 1 h-Ag-ASPSM@SS and 4 h-Ag-ASPSM@SS,the 2 h-Ag-ASPSM@SS exhibited better inhibitory effect on Staphylococcus aureus and pseudomonas aeruginosa.After co-culturing with bacteria for 42 and 84 days,the number of viable bacteria on the spread plate method was significantly lower in the 2 h-Ag-ASPSM@SS group compared to the stainless steel and ACNs groups.After co-culturing with Staphylococcus aureus for 84 days and Pseudomonas aeruginosa for 42 days,the number of viable bacteria on the surface of the eluate from the ACNs group was higher than that of the stainless steel group.(3)CCK-8 assay,live/dead staining and lactate dehydrogenase activity of cell supernatant displayed that 2 h-Ag-ASPSM@SS did not have obvious cytotoxicity.ACNs showed obvious cytotoxicity.(4)After co-culture with Staphylococcus aureus for 12 weeks,the residual viable bacteria on the surface of 2 h-Ag-ASPSM@SS group was less than that of stainless steel group,and the residual viable bacteria on the surface of the ACNs group was more than that of stainless steel group.Compared with the stainless steel group,the sensitivity to vancomycin was significantly decreased in the ACNs group(P<0.001),and there was no significant change in sensitivity to vancomycin in 2 h-Ag-ASPSM@SS group(P>0.05).(5)The above results indicate that the silver nanoparticle coated stainless steel greatly improves the deposition efficiency of silver nanoparticles on the stainless steel surface and has long-lasting antibacterial properties and good cell compatibility.