1.Surface Enhanced Raman Scattering Spectrum Recognition for Trace Detection of Common Drugs in Urine
Lei WANG ; Shuxia GUO ; Yinzhen DAI ; Liangbao YANG ; Guokun LIU
Chinese Journal of Analytical Chemistry 2015;(1):33-39
Assembling an adapted smoothing method and a classifier of wavelet transform combined support vector machine ( SVM) , a Raman spectrum recognition approach was built for low signal noise ratio situation. Firstly, spectra data were denoised by the adapted smoothing method. The smoothing window was adapted to the signal noise ratio, which would effectively remove noise with the intensity of the signal well remained. Secondly, the wavelet transform was used for dimension reduction of the data. The decomposition level of wavelet transform was optimized according to the best classification result of the training set. Lastly, SVM was used for classification. Cross Validation ( CV ) was applied to obtain the optimized parameters of SVM. Conditions for the effective parameters were searched considering the relation between the cross_validation result and the classification accuracy. Combined with the surface enhanced Raman scattering ( SERS ) technology , the developed spectrum recognition approach was used for qualitative analysis of methamphetamine ( MAMP ) and 3, 4_methylenedioxymethamphetamine ( MDMA ) in peopleˊs urine, where the detecting accuracy is above 95. 0%. The uniform Au nanorods (NRs) SERS substrate synthetized by the Hefei Institute of Intelligent Machines of Chinese Academy of Sciences was used for the experiment. Raman spectra were acquired using an Inspector Raman ( DeltaNu) spectrometer, with the excitation wavelength of 785 nm and the integrate time of 5 seconds.
2.Comparison of dual-source parallel radio frequence transmission liver MRI at 3.0 T with conventional MRI
Zhuren LUO ; Dan WANG ; Baozhong SHEN ; Xilin SUN ; Guokun WANG ; Fang LIU ; Shuguang HU ; Chan QUEENIE
Chinese Journal of Radiology 2011;45(11):1032-1035
Objective To investigate the role of dual-source parallel radio frequence (RF) and single-source excitation in liver imaging at 3.0 T MR.Methods This study was a retrospective analysis.One hundred and seven subjects underwent a 3.0 T TX MR scanning including axial spectrally selective attenuated inversion recovery (SPAIR) T2WI,axial DWI and coronal balanced-fast field echo( Balanced FFE).Each sequence was carried out with both single-source and dual-source RF excitation.Student's t test was used to compare the differences between single-source and dual-source RF excitation in the image uniformity,signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR).Wilcoxon signed rank test was used to determine whether there was difference between conventional and parallel transmission in the score of image quality.Reader agreement was assessed using the Cohen's Kappa test.Results For the image uniformity,there was significant difference between single-source and dual-source excitation (418.40 ± 66.75 for single-source vs.416.26 ± 50.61 for dual-source,t =2.524,P < 0.05 ).There also existed significant difference between single-source and dual-source excitation in SNR and CNR,respectively.The SNR and CNR of parallel transmission (22.03 + 12.16 and 18.33 ± 10.01,respectively) were both higher than those of single transmission (20.36 ± 11.21 and 15.22 ± 8.95,respectively) ( t =- 2.630,P < 0.05 for SNR and t =- 4.238,P < 0.05 for CNR).Image quality comparisons revealed significantly better results with dual-source than single-source RF excitation at SPAIR T2 WI ( 1.40 + 0.42 vs.1.81 ± 0.27 ),DWI ( 1.08 ± 0.40 vs.1.63 ± 0.36 ) and Balanced FFE sequence ( 0.95 ± 0.45 vs.1.65 ± 0.37,Z =- 5.894,- 5.801 and - 6.985,respectively,P < 0.01 ).In the comparison of image quality,the agreement between the two readers was very good ( Kappa > 0.8,P < 0.05 ).Conclusion Dual-source parallel RF excitation MR imaging in liver enables reducing dielectric shading,improving homogeneity of the RF magnetic induction field,and increasing SNR and CNR at 3.0 T.
3.Application of continuous nursing based on hybrid electronic platform and fragmented time concept in out-of-hospital rehabilitation of patients with anterior cruciate ligament reconstruction
Yating WEN ; Xiaoping WANG ; Jun LIU ; Qingjun LIU ; Guokun SUN ; Yun XU
Chinese Journal of Practical Nursing 2023;39(10):729-736
Objective:To explore the application effect of continuous nursing based on hybrid electronic platform and fragmentation time in the out-of-hospital rehabilitation of patients with anterior cruciate ligament reconstruction.Methods:This was a randomized controlled study. From April 2020 to October 2021, a total of 90 patients undergoing anterior cruciate ligament reconstruction in Weifang People′s Hospital were selected as the research objects by convenience sampling. Forty patients from April to December 2020 were selected as control group, and 45 patients from January to October 2021 were selected as intervention group. The control group implemented routine discharge guidance and follow-up, while the intervention group was given continuous nursing plan based on the concept of hybrid electronic platform and fragmented time. Before operation and 1, 3 and 6 months after operation, the knee range of motion and Lysholm score of patients in the two groups were analyzed. At 1, 3 and 6 months after operation, the rehabilitation exercise compliance score, self-efficacy score and knee stability examination of the two groups were analyzed.Results:A total of 41 patients in each group completed the study. At 1 month after operation, the knee range of motion, Lysholm score, rehabilitation exercise compliance score and self-efficacy score of intervention group were (96.46 ±3.58) ° and (53.54 ± 6.57), (69.17 ± 6.27), (4.01 ± 0.38) points, respectively. In the control group, they were (89.02 ± 4.22)° and (45.02 ± 7.61), (56.78 ± 8.45), (3.61 ± 0.42) points. At 3 months after operation, they were (136.83 ± 4.30)° and (72.76 ± 4.96), (60.71 ± 5.87), (4.97 ± 0.32) points in the intervention group, (133.54 ± 3.58)° and (69.83 ± 6.65), (56.73 ± 8.57), (4.83 ± 0.45) points in the control group, respectively. At 6 months after operation, they were (139.39 ± 1.99)° and (85.61 ± 6.11), (57.71 ± 7.41), (6.58 ± 0.96) points in the intervention group, (138.29 ± 2.65)° and (81.80 ± 6.38), (47.90 ± 6.02), (6.35 ± 1.23) points in the control group, respectively. The knee range of motion, Lysholm score and rehabilitation exercise compliance score of the intervention group were better than those of the control group at 1, 3 and 6 months after operation, and the differences were statistically significant ( t values were 2.12-8.61, all P<0.05). The self-efficacy score of the intervention group was higher than that of the control group at 1 month after operation, and the difference was statistically significant ( t=4.57, P<0.05). Conclusions:The continuous nursing program based on hybrid electronic platform and fragmented time can improve the knee function of patients with anterior cruciate ligament reconstruction in the early postoperative period, improve the compliance of rehabilitation exercise and the level of early self-efficacy.
4.Thevalueof3.0T MRreducedfield-of-viewIVIM diffusionweightedimaging ondistinguishingprostatecancerandprostatehypertrophy
Jianfei LI ; Jiwei HUANG ; Jia WANG ; Guokun LIU ; Jianli LI ; Sujun YANG
Journal of Practical Radiology 2019;35(7):1099-1102
Objective Toinvestigatethevalueof3.0T MRreducedfield-of-view (rFOV)IVIM-DWIondistinguishingprostate cancerandprostatehypertrophy.Methods 30patientswithpathologicallyprovenprostatecancerand38patientswithprostatehypertrophy accordingtotheresultsofbiopsywereanalyzedretrospectively,whounderwent3.0T MRrFOV multipleb-valueDWIscanpreoperatively.The DWIscanwasperformedusing11b-valuesof0,30,50,100,150,200,400,800,1000,1500and2000s/mm2.ADC,slowdiffusion coefficient(D),fastdiffusioncoefficient(D?)andperfusionfraction(f)weremeasuredoncancerousfociandprostatehyperplasiafoci.Allofthe datawereanalyzed.Results TheADC,D,D?andfvaluesoftheprostatecancerwere(0.61±0.12)×10-3 mm2/s,(0.41±0.08)×10-3 mm2/s, (88.0±40.3)×10-3mm2/s,289.3%±29.4%,respectively,and(09.0±01.7)×10-3mm2/s,(05.4±01.3)×10-3mm2/s,(46.1±15.3)×10-3 mm2/s, 474.3%±10.85%,respectively,forprostatehypertrophy.Thedifferencesamongthefourparameterswerestatisticallysignificant(P<0.05).The areasofADC,D,D?andfvaluesunderROCcurvestodistinguishbetweenprostatecancerandprostatehypertrophywere09.32,08.27,01.58,0.976, respectively.Conclusion 3.0T MRrFOVIVIM-DWIcanreflectthetruewaterdiffusion motionandperfusionintheprostate,and maycontributetothedifferentialdiagnosisofprostatecancerandbenignprostatehyperplasia.