1.Interaction of δ-opioid Receptor with Membrane Transporters: Possible Mechanisms in Pain Suppression by Acupuncture
Zhijie YANG ; Guobin BAO ; Haiping DENG ; Huiming DU ; Quanbao GU ; Gang PEI ; Lu PU ; Schwarz WOLFGANG ; Peng XIA
Journal of Acupuncture and Tuina Science 2008;6(5):298-300
Objective: To investigate the possible mechanisms in acupuncture analgesia by interaction of &opioid receptor with neurotransmitter transport proteins or the Na+-K+pump. Methods: Microinjection of respective heterologous cRNA into the Xenopus oocytes as a model system, and measurement of steady-state currents under two-electrode voltage clamp. Results: The co-expression of the δ-opioid receptor with GAT1, EAAC1 or the sodium pump resulted in reducing activity of the respective transporter. Opioid receptor activation affected transporter activity in different ways: 1) GAT1 was further inhibited; 2) EAAC1 was stimulated; 3) Na+-K+ pump activity interfered with agonist sensitivity of DOR. Pump inhibition led to higher sensitivity for DPDPE. Conclusion: GABA transporter inhibition and glutamate transporter stimulation may counteract pain sensation by affecting the neurotransmitter concentration in the synaptic cleft and, therefore, may contribute synergistically to pain suppression by acupuncture. Sodium pump inhibition by endogenous ouabain may amplify these effects. These synergistic effects may be the molecular mechanism of inhibiting pain sense and/or acupuncture analgesia.
2.Application of holographic image navigation in urological laparoscopic and robotic surgery
Gang ZHU ; Jinchun XING ; Guobin WENG ; Zhiquan HU ; Ningchen LI ; He ZHU ; Pingsheng GAO ; Zhihua WANG ; Weizhi ZHU ; Kai ZHANG ; Hongbo LI ; Zhun WU ; Rui ZHU ; Xifeng WEI ; Yanan WANG ; Qun XIE ; Bing FU ; Xinghuan WANG ; Lin QI ; Xin YAO ; Tiejun PAN ; Delin WANG ; Nan LIU ; Jianguang QIU ; Jianggen YANG ; Bao ZHANG ; Zhuowei LIU ; Hui HAN ; Gang LI ; Bin ZHANG ; Manli NA ; Jingjing LU ; Lei WANG ; Zichen ZHAO ; Yanqun NA
Chinese Journal of Urology 2020;41(2):131-137
Objective To evaluate the clinical value of holographic image navigation in urological laparoscopic and robotic surgery.Methods The data of patients were reviewed retrospectively for whom accepted holographic image navigation laparoscopic and robotic surgery from Jan.2019 to Dec.2019 in Beijing United Family Hospital and other 18 medical centers,including 78 cases of renal tumor,2 cases of bladder cancer,2 cases of adrenal gland tumor,1 cases of renal cyst,1 case of prostate cancer,1 case of sweat gland carcinoma with lymph node metastasis,1 case of pelvic metastasis after radical cystectomy.All the patients underwent operations.In the laparoscopic surgery group,there were 27 cases of partial nephrectomy,1 case of radical prostatectomy,2 cases of radical cystectomy and 2 cases of adrenalectomy.In the da Vinci robotic surgery group of 54 cases,there were 51 cases of partial nephrectomy,1 case of retroperitoneal lymph node dissection,1 case of retroperitoneal bilateral renal cyst deroofing and 1 case of resection of pelvic metastasis.There were 41 partial nephrectomy patients with available clinical data for statistic,with a median age of 53.5 years (range 24-76),including 26 males and 15 females.The median R.E.N.A.L score was 7.8 (range 4-11).Before the operation,the engineers established the holographic image based on the contrast CT images and reports.The surgeon applied the holographic image for preoperative planning.During the operation,the navigation was achieved by real time fusing holographic images with the laparoscopic surgery images in the screen.Results All the procedures had been complete uneventfully.The holographic images helped surgeon in understanding the visual three-dimension structure and relation of vessels supplying tumor or resection tissue,lymph nodes and nerves.By manipulating the holographic images extracorporeally,the fused image guide surgeons about location vessel,lymph node and other important structure and then facilitate the delicate dissection.For the 41 cases with available clinical data including 23 cases of robotic-assisted partial nephrectomy and 18 cases of laparoscopic nephrectomy,the median operation time was 140 (range 50-225) min,the median warm ischemia time was 23 (range 14-60) min,the median blood loss was 80(range 5-1 200) ml.In the robotic surgery group,the median operation time was 140 (range 50-215)min,the median warm i schemia time was 21 (range 17-40)min,the median blood loss was 150(range 30-1 200)ml.In the laparoscopic surgery group,the median operation time was 160(range 80-225)min,the median warm ischemia time was 25 (range 14-60)min,the median blood loss was 50 (range 5-1 200) ml.All the patients had no adjacent organ injury during operation.There were 2 cases with Clavien Ⅱ complications.One required transfusion and the other one suffered hematoma post-operation.However,the tumors were located in the renal hilus for these 2 cases and the R.E.N.A.L scores were both 11.Conclusions Holographic image navigation can help location and recognize important anatomic structures during the surgical procedures..This technique will reduce the tissue injury,decrease the complications and improve the success rate of surgery.