1.Operative Technique and Curative Effect Analysis of Minor-Incision Cholecystectomy
Qin DONG ; Xingkai MENG ; Guangzhong KONG ; Junbin LIU
Chinese Journal of Bases and Clinics in General Surgery 2003;0(04):-
Objective To discuss the operative technique and curative effect of minor-incision cholecystectomy.Methods The clinical data of 672 patients with application of mini-cholecystectomy from June 2001 to June 2009 were analyzed.Perioperative management and operative technique were emphasized.Results Six hundred and fifty-two cases (97.0%) were cured with mini-cholecystectomy and 20 cases (3.0%) with incision lengthened.Operation time was (40.0?10.0) min.One case with hemorrhoea during operation was cured by interventional embolotherapy.Bile duct injury was found in 1 case during operation,and adopted suture with T tube.There were no infection of incisional wound or death in this study.Conclusion On the basis of skillful conventional cholecystectomy,by controlling indication and improving operative technique,it is an economical and safe way to perform minor-incision cholecystectomy.
2.Preliminary application of CT and 3D-DSA data sources in 3D printing of intracranial arteriovenous ;malformations
Jianyi LI ; Xiangxue KONG ; Zhanglin WANG ; Peng PENG ; Guangzhong CHEN ; Mengqi DONG ; Kun QIN ; Chao PENG
Chinese Journal of Cerebrovascular Diseases 2016;(2):78-81
Objective To compare the effect of thin-sliced enhanced CT scanning and 3D-DSA data sources in the 3 D printing data reconstruction of intracranial arteriovenous malformation (AVM ). Methods Five patients with AVM were selected prospectively,3 were Spetzler-Martin grade II and 2 were grade III. Two of them used 256-slice spiral CT thin slice enhanced scanning. Three used the 3D-DSA rotating imaging,and the DICOM raw data of the examination results were extracted. Digital processing was performed by using the Mimics software,and the 3 D printing was performed according to the ratio of 1∶1 obtaining the solid model and the effects were compared. Results Using the data source 3 D printing of 256 slice spiral CT thin-slice enhanced scan could obtained skull and blood vessel image information and could reveal the smallest diameter of 0. 9 mm vessel,however,the fine branch structures of the vessel were difficult to distinguish. The 3D printing based on 3D-DSA data,although the digital subtraction did not have the skull data information,the vascular branches showed more abundant. It could reveal the smallest diameter of 0. 9 mm vessel. Conclusions Using the CT thin-slice enhanced scan or 3D-DSA data source can obtain reconstruction images of AVM nidus,and 3D-DSA shows that the better effect for spatial structure of AVM nidus. It is helpful to the design of preoperative treatment scheme and the development of corresponding auxiliary tools.