1.Design of Simple Integral Coefficient Notch Filter to Remove Power-line Interference in High Sampling Rate
Space Medicine & Medical Engineering 2006;0(02):-
Objective To meet the demand of ECG signal processing in high sampling rate,a simple and narrowband power-line interference notch filter is designed.Methods Based on the band elimination filter which was combined with counteraction of zeros and poles and the interpolation theory,we designed a simple,integral coefficient filter with adjustable filter bandwidth.To eliminate the Gibbs phenomena,we adopted the average filter in linear segments which was designed by the former.Results With our designed filter,50 Hz power-line interference in high sampling rate was efficiently removed,and the filter coefficients were simple,integral,and convenient.Conclusion The new design can produce a narrowband notch filter in high sampling rate,remove the 50 Hz power-line interference effectively,and retain the significant signal as much as possible to meet the needs of ECG analysis.
2.Main algorithm of coronary blood flow and velocity based on angiographic images
International Journal of Biomedical Engineering 2008;31(3):155-158
The severity of coronary artery diseases is assessed based on morphological and functional stenosis.The study Oil detection of coronary artery diseases based on morphological lesions has unveiled its short comings for evaluation of the seriousness of the disease.Therefore,many research groups diagnose the coronary artery diseases by functional stenosis.From functional aspect,studies of x-ray angiography algorithms for blood flow and velocity measurement are potentially clinically important and are an actively researched subject,which Can accurately diagnose the coronary diseases from functional stenosis aspect.Based on the angiographic images,the article describes formulation and characteristics of existing coronary blood flow and velocity techniques such as tracking and computational methods.Tracking methods can be divided into four classes:bolus transport time algorithms,continuous velocity determination from two-dimensional(time-distance)parametric images,contrast traversal distance algorithms,and droplet tracking algorithms.Computational methods can be divided into six classes:indicator-dilution or Stewart-Hamilton method,first-pass distribution analysis,inverted continuity equation algorithms,inverse mass transport problem approach,optical flow type algorithms,and the fluid continuity method.
3.Analysis of Heart Rate Variability Signal Based on Cao Algorithm.
Li ZHU ; Jianhua WU ; Guangshu HU
Space Medicine & Medical Engineering 2006;0(02):-
Objective To further analyze the chaos characteristics of heart rate variability(HRV) signals.Methods Analyzed HRV was obtained from 40 healthy subjects(20 olds,20 youngs) by means of Cao algorithm;Stability criteria was proposed to determine minimum embedding dimension;Meanwhile,we advanced a new quantative analysis method of studying HRV deterministic component,and applied the method to the old and young groups.Results Each subject's HRV was composed of both stochastic and deterministic components;Stability criteria could solve the subjective problem when determine minimum embedding dimension by Cao algorithm;Deterministic component in healthy old subjects was higher than the young.Conclusion In this paper,we have proved that HRV is deterministice chaos;Stability criteria works well for determining minimum embedding dimension;HRV decreases as age increases.
4.Diagnosis methods of Alzheimer’s disease based on signal and image processing
Yue HUANG ; Xuezhi SUN ; Guangshu HU
International Journal of Biomedical Engineering 2006;0(06):-
Alzheimer’s disease (AD), one of the most common causes of dementia in the elderly, is a progressive neurodegenerative disorder. Accurate diagnosis in the early stage of AD is crucial for its treatment. Several methods based on signal processing and image analysis are presented. In particular, neuron image processing which plays an important role in AD diagnosis and its pathological analysis is discussed in detail.
5.The progress of algorithms applied in digital hearing aid.
Xianbo XIAO ; Ningyu WANG ; Guangshu HU
Journal of Biomedical Engineering 2004;21(4):694-698
The paper introduced the structure of digital hearing aid in brief firstly, then analyzed and compared signal processing algorithms applied in digital hearing aid, serving respectively in multi-channel frequency compensation, noise reduction and acoustic feedback cancellation. Finally, several special signal processing techniques used in digital hearing aid were introduced.
Algorithms
;
Analog-Digital Conversion
;
Hearing Aids
;
Humans
;
Prosthesis Fitting
;
Signal Processing, Computer-Assisted
;
instrumentation
;
Speech Discrimination Tests
6.Clinical application of serum microRNA-198 and microRNA-365 combined with gastroscopy in diagnosis of chronic atrophic gastritis
Guangshu LI ; Fen HU ; Bibo ZHONG
China Journal of Endoscopy 2024;30(6):23-29
Objective To analyze the value of serum microRNA-198(miRNA-198)and miRNA-365 combined with gastroscopy in diagnosis of chronic atrophic gastritis(CAG).Methods 180 patients with CAG who were treated from January 2022 to January 2023 were regarded as the observation group,and 180 patients with chronic non-atrophic gastritis in the same period were studied as control group.According to the degree of atrophy,patients with CAG were grouped into 56 mild cases,84 moderate cases and 40 severe cases.The subjects were examined by gastroscopy,and the relative expression levels of miRNA-198 and miRNA-365 in serum were detected by real-time fluorescent quantitative polymerase chain reaction(qRT-PCR).The diagnostic value of serum miRNA-198 and miRNA-365 levels in patients with CAG was analyzed by receiver operator characteristic curve(ROC curve).The diagnostic value of serum miRNA-198 and miRNA-365 combined with gastroscopy for CAG was analyzed with four grid tables.Results Compared with the control group,the levels of serum miRNA-198 and miRNA-365 in patients with CAG in the observation group were obviously lower,with the aggravation of atrophy,the levels of serum miRNA-198 and miRNA-365 decreased in turn,the differences were statistically significant(P<0.05);the area under the curve(AUC)of serum miRNA-198 and miRNA-365 levels in the diagnosis of CAG was 0.898 and 0.945,respectively,the sensitivity,specificity and accuracy of combined gastroscopy in the diagnosis of CAG were 98.33%,81.11%and 89.72%,respectively,its diagnostic efficacy was higher than that of serum miRNA-198,miRNA-365 and gastroscopy alone.Conclusion The levels of serum miRNA-198 and miRNA-365 in patients with CAG are decreased,they have certain diagnostic value for CAG,their combination with gastroscopy can obviously improve the diagnostic value of CAG.