1.Content Determination and Analysis of Flavonoids in Buckwheat from Guizhou Province Content Determination and Analysis of Flavonoids in Buckwheat from Guizhou Province
Mingyan CHI ; Guangfang LI ; Lina LIU
China Pharmacy 2016;27(21):2969-2971,2972
OBJECTIVE:To establish a method for contents determination of rutin,quercetin and total flavonoids in Buck-wheat,and compare the difference of flavone in buckwheat in different varieties and areas. METHODS:HPLC was adopted for content determination of rutin and quercetin:the column was Aglient C18 with mobile phase of methanol-0.4%phosphoric acid(gra-dient elution)at a flow rate of 1 ml/min,detection wavelength was 360 nm,column temperature was 40 ℃,and injection volume was 10 μl;UV spectrophotometry was adopted for content determination of total flavonoids:reference solution was methanol,de-tection wavelength was 360 nm,the standard was rutin. Statistical method was used to analyze the differences among the Fagopy-rum tataricum,F. esculentum and flavonoids of F. tataricum from different areas. RESULTS:The linear range was 0.400 9-16.03 μg for rutin (r=0.999 4) and 0.009 9-0.396 0 μg for quercetin (r=0.999 7),RSDs of precision,stability and reproducibility tests were lower than 2%,recoveries were 99.33%-104.00%(RSD=1.32%,n=9) and 96.92%-101.66%(RSD=1.60%,n=9),re-spectively. The linear range of total flavonoids(recovded by rutin)was 4.14-41.4 mg/L(r=0.999 9),RSDs of precision,stability and reproducibility tests were lower than 2,and recovery was 96.07%-101.96%(RSD=2.63%,n=9). The content of flavonoids on F. esculentum is significantly higher than in F. tataricum from the same area,and F. tataricum in Bijie area is better than other places. CONCLUSIONS:The method is simple,stable,reproducible,and can be used for the contents determination of rutin, quercetin and total flavonoids in F. esculentum. The study can provide theoretical basis for developing and using buckwheat.
2.The ECG tube current modulation technique of dual source CT in clinical application of coronary angiography
Guangfang TUO ; Yongshu LAN ; Guangcai TANG ; Zhenlin LI ; Lu ZHENG
Journal of Practical Radiology 2016;32(8):1289-1292
Objective To explore the application value of ECG tube current modulation technology of dual source CT in coronary angiography,compared with retrospectively ECG-gated technique.Methods 200 patients were randomly divided into ECG tube current modulation group (Group A)and retrospectively ECG-gated group(Group B).In Group A,the main parameters were the exposure time windows of full dose,which were set according to different heart rates.χ2 test was adopted in the subjective score,and t test was used in the objective score and radiation dose.Results There was no statistical significance in image quality between the two groups(χ2 =2.125,tnoise =-0.557,P >0.05 );The effective dose (ED)of Group A and Group B were (3.30±0.40)mSv and(6.90±1.76)mSv,respectively.The difference was statistically significant (t ED =-1 9.954,P <0.05).The radiation dosage of Group A was 52% lower than that of Group B.Conclu-sion Compared with retrospectively ECG-gated technique,the ECG tube current modulation technique ensures the image quality, and at the same time it can significantly reduce the radiation dose,therefore,it can be used as a routine examination technique of cor-onary angiography.
3.The Investigation of ABO,Rh Blood Group in Jirou and Bulang Nationality in Yunnan Province
Guangfang XU ; Jun LIAN ; Muying YANG ; Xuehong LI ; Qin HE ; Jiayou CHU
Journal of Kunming Medical University 2006;0(06):-
p.R-gene frequency in Jinuo nationality is higher than that in Bulang nationality.Conclusion Discrepancies exist in the antigen of blood types in different nationalities and each nationality has its own characteristics.