1.The compilation of the VMI and its supplement test norms for children in Xi'an city
Journal of Xi'an Jiaotong University(Medical Sciences) 2001;22(2):159-161
Objective To provide an effective instrument assessed the ability of children's visual-motor integration in China.Methods 1*!798 children aged 3 to 18 years old were randomly sampled from Xi'an city and were tested with VMI-4R test.The reliability and validity were then analyzed.Results The norms of aged-equivalent,percentile,and standard scores were established.Split-half reliability,coefficient KR20,test-rerest reliability,and interscorer reliability ranged from 0.90 to 0.96(P<0.01).There are moderately-highly correlation between VMI-4R with WISC-R,WPPSI-R,CRT,FQS,Drawing-A-Man test respectively.Conclusion VMI-4R has good reliability and stable construction.It can effectively reflect the level of visual-motor integration.It is worth while to use widely as instrument for intelligence screenging and development assessing.
2.Visual-motor integration test for screening hearing handicap in children: feasibility of large-scale application
Guogang LUO ; Zhen HAN ; Gongzheng LI ; Tianshou ZHAO ; Ling LIU
Chinese Journal of Tissue Engineering Research 2005;9(24):234-237
BACKGROUND: Visual-motor integration (VMI) test was introduced into China in the 1970s and 1990s and widely used for evaluation and identification of problems in intellectual development and learning ability in children due to its good applicability without limitations by language and cultural background.OBJECTIVE: To assess the value of developmental test of VMI in children with hearing handicap, and evaluate its practical feasibility in largescale screening of intelligence problems in these children by comparing its reliability and validity with the norms of children in Shaanxi Province and the USA.DESIGN: A controlled correlation and multiple stepwise regression analysis with randomized cluster sampling.SETTING: Neurological Department of the First Hospital Affiliated to Medical College of Xi' an Jiaotong University.PARTICIPANTS: From January 1998 to December 2000, 638 children under 18 years of age with hearing handicaps were chosen from 6 schools of deaf-mutes in Xi'an City, Xianyang City, Chang'an County, Huxian County,and Lintong County in Shaanxi Province. Another 43 children with hearing handicap including 23 male and 20 female children aged (11.62±1.98) years were selected randomly for EEG and brain electrical activity mapping (BEAM) examination, who had a mean development quotient of VMI of 86.60±15.68. The children were divided by the development quotient into two groups, namely those with development quotient < 86.6 (n=20) and those with development quotient ≥ 86.6 (n=23). METHODS: ① The VMI test was performed in accordance with the Fourth edition of VMI Manual by Beery K.E. The test was terminated when the testee failed to correctly copy three consecutive geometrical figures without time limit. The scale score varied from 0 to 27. ② The reliability test included split-half reliability test in which the items were split into two parts according to odd-even number, re-test reliability that tested the same group of children again in two months and inter-examiner reliability in which two examiners were asked to grade the same test paper.③ The validity test included structural and correlation validity test. Three well-revised and already established norms of scales in China, including Hiskey- Nebraska test of learning aptitude (H-NTLA), performance scale of Wechsler intelligent scale for children (PS-WISC) and Combined Raven's test (CRT), have been chosen as the structure validity criteria. The performance IQ of PS-WISC, learning quotient of H-NTLA, percentile rank of CRT and standard score of VMI were taken respectively for each test in this study.Academic achievements and teachers' and parent's rating were used as the validity correlation criteria. During the administration procedure, a card describing the requirements in detail were presented to the deaf children with reading capacity, while for those too young to read, the teacher was asked to help translate the requirements using standard sign language, but no any hints or clues in relation with the test contents were given. ④ The test did not start until the subjects fully understood the requirement (7314/F/W DYD-300A).EEG recording was performed with the leads deposited according to the international standard 10/20 lead system. Routine EEG had been recorded at least 30 minutes for visual assessment, and stable and representative waves for 120 seconds free of biases or inferences were recorded using unipolar lead from the subjects at rest with the eyes closed and stored in computer.Experienced EEG experts were asked to select the most representative waves of 20 seconds in a double-blind manner to compute the absolute power spectrum of the brain wave.MAIN OUTCOME MEASURES: Reliability and validity of VMI test,relationship between VMI ability and cerebral electrophysiological changes.RESULTS: Totally 638 children under 18 years old with hearing handicap were involved, of whom 72 were eliminated because of lack of data, congenital disease or central nervous system diseases. Finally 566 cases were available for analysis, including 346 male and 220 female children with an average age of (12±3) years. ① The reliability of VMI reached an average of 0.92, varying from 0.63 to 0.99 in each group. The equivalent age corresponding to the scores of the VMI test norm established for the 566 healthy deaf children was lower by an average of (1.79±0.9) years than the equivalent age in the norms of the normal children in Shaanxi Province delayed and USA. ② The standard score of VMI test showed the highest correlation coefficient of 0.661 0 with the learning quotient of H-NTLA, while the correlation with PS-WISC and CRT were 0.357 6 and 0.517 4, respectively.③ Children with higher VMI score showed more powerful absolute spectrum among frequency rangesδ,θ,αl and total power spectrum in the central, parietal and occipital regions of the left hemisphere, respectively.CONCLUSION: VMI test can efficiently reflect the development status of visual-motor integration or intelligence of the school-age deaf children and represent the level of central EEG activity.
3.Genotype identifications of ESBLs and AmpC β-Iactamase of a Enterococcus gallinarum isolated from chloebia gouidiae
Li YUAN ; Xiuling FU ; Jianhua LIU ; Gongzheng HU ; Juan MO ; Yushan PAN ; Yu KANG
Chinese Journal of Veterinary Science 2009;29(7):858-863
The genotypes of extended spectrum β-laetamases(ESBLs) and AmpC β-lactamases produced by Enterococcus gallinarum isolated from chloebia gouldiae were determined to elucidate the evolution mechanism of the resistant genes.The minimum inhibitory concentrations (MICs) of 18 antibacterial drugs against the Enterococcus gallinarum were detected with two dilution method,and the ESBLs and AmpC β-lactamases from the bacterium were amplified by PCR using the primers of TEM,SHV,CTX-M,ACC,CIT,DHA,EBC,FOX and MOX,respectively.The PCR products were cloned and then the cloned fragments were sequenced to identify their genotypes and subtypes.The bacterium was proved to be a ESBL-producing and AmpC β-lactamase-producing bacterium,showing severe resistant to the other drugs,except the third and forth cephalosporins,carbopenems and fosfomycin.Compared with that of AJ847364 (TEM-116),the sequence of the TEM-type was characterized by two nucleotide mutations (512T→A and 695A→C),which led to two mutations of amino acids(17111e→Lys and 232Lys→Thr),showing that the detected TEM-type was a new genotype,the sequence of the AmpC β-lactamase was similar to that of EF078894 (ACT-like type)with a 97% homology.The genotype of ESBLs of Enterococcus gallinarum was a new TEM-type derived from the TEM-type ESBLs of klebstella pneumoniae isolated from the same avian.The genotype of AmpC lactamase was ACT-type,which probably concerned with β-1actam antibiotics used.
4.The clinical application value of dual source CT quantification volume imaging to forecast lung cancer patients' postoperative pulmonary function changing: a prospective study.
Min LI ; Chaoyang LIANG ; Juntang GUO ; Yongfu MA ; Liang ZHOU ; Pu YANG ; Gongzheng YANG ; Yang LIU
Chinese Journal of Surgery 2014;52(10):734-738
OBJECTIVETo probe the clinical application and value of dual source CT quantification volume imaging to forecast lung cancer patients' postoperative pulmonary function changing.
METHODSBetween June 2012 and June 2013, there were 233 patients (121 male patients and 112 female patients, with a mean age of (53 ± 16) years) who accepted the thoracoscope lobectomy or unilateral holo-lungs pneumonectomy accepted pulmonary function test before and after 3 months of the surgery. CT scan was conducted at both inspiration phase and expiration phase before the surgery and the lung volume of the single lobe, the pixel exponential distribution histogram, and the average lung density were measured after CT scan. The discrepancy and correlation between the preoperative lung volume accepted by CT and preoperative, postoperative pulmonary function index were compared.
RESULTSThe CT volume scan showed that average lung density of the superior part at decubitus position is -(870 ± 22) HU, the inferior part was -(767 ± 16) HU (t = 3.13, P < 0.01). The volume ratio of the right upper lobe, right middle lobe, right lower lobe, left upper lobe, left lower lobe were 20.5%, 10.3%, 23.1%, 24.6%, 21.5%, whole-right lung was 53.9% and whole-left was 46.1%. There were high correlation between CT volume index and preoperative routine pulmonary function index such as total lung capacity, forced vital capacity (FVC), forced expiratory volume in the first second (FEV(1)), residual volume, and FEV(1)/FVC. The highest correlation coefficient were 0.92, 0.76, 0.70, 0.85, 0.56 (t = 3.14, 3.05, 2.86, 3.09, 2.68; all P < 0.01). The highest correlation coefficient for the postoperative pulmonary function index were 0.87, 0.68, 0.75, 0.81, -0.64 (t = 3.10, 2.85, 3.05, 3.02, 2.79; all P < 0.01).
CONCLUSIONSIt is feasible to use dual source CT quantification volume imaging to predict lung cancer patients' postoperative pulmonary function alteration, which can provide precise predictive value of these patients. CT quantification volume imaging technology has important clinical application value.
Adult ; Aged ; Female ; Forced Expiratory Volume ; physiology ; Humans ; Lung ; physiology ; Lung Neoplasms ; physiopathology ; surgery ; Male ; Middle Aged ; Pneumonectomy ; Postoperative Period ; Prospective Studies ; Respiratory Function Tests ; Tidal Volume ; physiology ; Tomography, X-Ray Computed ; methods ; Vital Capacity ; physiology