1.A STUDY OF INTERFACE AND CORROSION BEHAVIOR BETWEEN IMPLANT ABUTMENT AND CASTING GOLD ALLOY.
Mee Kyoung SON ; Jang Seon MA ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 1999;37(5):672-686
The purpose of this study was to compare the casting problem and corrosion behavior in two types of HL Hexed abutments of the Steri-Oss system : gold/plastic coping and gold coping. The anodic Polarization behavior, the galvanic corrosion between abutments and Type III gold alloys, before and after casting were analyzed, and the crevice corrosion of casting samples was analyzed with the CPPT test and the SEM. The results are as follows ; 1. Anodic polarization behavior of samples ; Before casting, gold/plastic coping and gold coping was shown to have a similar corrosion patterns. TypeIII casting gold alloy was shown to have a lower corrosion potential and passivation film. Corrosion potential of the case of gold/plastic coping after casting was higher than that of gold coping, but the region of passivation film for gold/plastic coping was smaller than that of gold coping. 2. Galvanic corrosion behavior of samples ; Contact current density between casting gold alloys and gold/plastic before casting was higher than that between gold coping and casting gold alloy. Galvanic corrosion of samples after casting was shown to have similar contact current density. 3. Crevice corrosion behavior of samples ; Crevice corrosion resistance of casting sample using gold coping was lower than that of casting sample using gold/plastic coping, and a severe corrosion pattern was observed at the abutment-casting gold alloy interface by the SEM.
Alloys*
;
Corrosion*
;
Gold Alloys
2.THE AMOUT OF LOSS AND THE DEGREE OF SURFACE SMOOTHNESS OF GOLD ALLOY BY GOLD ALLOY POLISHING RUBBER POINT MATERIALS.
Myoung Hwa KIM ; Soon Ho YIM ; Moon Kyu CHUNG
The Journal of Korean Academy of Prosthodontics 1997;35(2):277-295
After clinical adjustment of dental casting restoration, re-polishing procedure is recommanded because the smooth gold sureface is lost. But there is the possibility to get more loose contact than that intended by loss of gold alloy according to the kinds of polishing materials and polishing time. Therefore in this study I polished type II gold alloy with 390gm force, 20,000rpm speed, and 8 kinds of gold alloy polishing materials, fabricated by 4 companies and then measured the amount of loss of gold alloy with Surfcorder SEF30D and observed alloy surfaces polished by 3 brown rubber points with SEM. The amount of loss of gold alloys polished with 8 kinds of polishing materials and the degree of smoothness of gold alloys according to polishing time and polishing materials were compared. The following results were obtained : 1. When the amount of loss of gold alloys polished with 3 kinds of brown rubber point was compared, Alphalex brown point had the most amount of alloy loss, followed in decreasing order by Shofu brown point and Eveflex brown point. There was statistically significant difference in the amount of alloy loss according to polishing materials. 2. When the amount of loss of gold alloys polished with 5 kinds of green rubber point was compared, Shofu green point had the most amount of alloy loss, followed in decreasing order by Alphaflex green point, Dedeco green clasp polisher, and Eveflex green point. There was statistically significant difference in the amount of alloy loss according to polishing materials except Alphaflex green point and Dedeco green clasp polisher. 3. When the amount of loss of gold alloys polished with all kinds of rubber point was compared, there was no significant difference in Eveflex brown point, Alphaflex green point, and Dedeco green claps polisher. 4. When average amount of alloy loss per 1 revolution by polishing materials was compared, Alphalex brown point had the greatest value as 0.329micrometer and Shofu supergreen point had the lowest value as 0.022micrometer. 5. When the degree of sureface smoothness of gold alloy polished with 3 kinds of brown rubber point was compared, in Alphalex brown point surface roughness was completely lost after 20 seconds polishing time, in Shofu brown point 30 seconds, in Eveflex brown point 40 seconds. But in every gold alloys fine scratch formed by rubber points was observed. Based on the results of this study, as rubber polishing materials used in polishing of dental casting restoration after clinical adjustment influenced on the tightness of occlusal or proximal contact, we should make dental casting restoration with minimum error through careful laboratory procedure and form very smooth surface of restoration with tripoli and rouge after use of silicone polishing materials.
Alloys*
;
Gold Alloys
;
Rubber*
;
Silicones
3.THE AMOUT OF LOSS AND THE DEGREE OF SURFACE SMOOTHNESS OF GOLD ALLOY BY GOLD ALLOY POLISHING RUBBER POINT MATERIALS.
Myoung Hwa KIM ; Soon Ho YIM ; Moon Kyu CHUNG
The Journal of Korean Academy of Prosthodontics 1997;35(2):277-295
After clinical adjustment of dental casting restoration, re-polishing procedure is recommanded because the smooth gold sureface is lost. But there is the possibility to get more loose contact than that intended by loss of gold alloy according to the kinds of polishing materials and polishing time. Therefore in this study I polished type II gold alloy with 390gm force, 20,000rpm speed, and 8 kinds of gold alloy polishing materials, fabricated by 4 companies and then measured the amount of loss of gold alloy with Surfcorder SEF30D and observed alloy surfaces polished by 3 brown rubber points with SEM. The amount of loss of gold alloys polished with 8 kinds of polishing materials and the degree of smoothness of gold alloys according to polishing time and polishing materials were compared. The following results were obtained : 1. When the amount of loss of gold alloys polished with 3 kinds of brown rubber point was compared, Alphalex brown point had the most amount of alloy loss, followed in decreasing order by Shofu brown point and Eveflex brown point. There was statistically significant difference in the amount of alloy loss according to polishing materials. 2. When the amount of loss of gold alloys polished with 5 kinds of green rubber point was compared, Shofu green point had the most amount of alloy loss, followed in decreasing order by Alphaflex green point, Dedeco green clasp polisher, and Eveflex green point. There was statistically significant difference in the amount of alloy loss according to polishing materials except Alphaflex green point and Dedeco green clasp polisher. 3. When the amount of loss of gold alloys polished with all kinds of rubber point was compared, there was no significant difference in Eveflex brown point, Alphaflex green point, and Dedeco green claps polisher. 4. When average amount of alloy loss per 1 revolution by polishing materials was compared, Alphalex brown point had the greatest value as 0.329micrometer and Shofu supergreen point had the lowest value as 0.022micrometer. 5. When the degree of sureface smoothness of gold alloy polished with 3 kinds of brown rubber point was compared, in Alphalex brown point surface roughness was completely lost after 20 seconds polishing time, in Shofu brown point 30 seconds, in Eveflex brown point 40 seconds. But in every gold alloys fine scratch formed by rubber points was observed. Based on the results of this study, as rubber polishing materials used in polishing of dental casting restoration after clinical adjustment influenced on the tightness of occlusal or proximal contact, we should make dental casting restoration with minimum error through careful laboratory procedure and form very smooth surface of restoration with tripoli and rouge after use of silicone polishing materials.
Alloys*
;
Gold Alloys
;
Rubber*
;
Silicones
4.THE EFFECTS OF METAL SURFACE TREATMENTS ON THE BONE STRENGTH OF POLYMETHYL METHACRYLATE BONDED REMOVABLE PROSTHESE.
The Journal of Korean Academy of Prosthodontics 1998;36(2):336-354
Traditionally, many kinds of mechanical bonding techniques were used for bonding resins to the surface of the metal alloys. If there is a seperation between resin and metal junction by stress accumulation and temperature change of oral cavity, the cracks or crazing may occur, accompanied by failure of resin bonding to metal. This study was designed to compare the shear bond strength of the type IV gold alloy and Cr-Co alloy surfaces treted with various methods and thermocyling. Universal Instron (Model 1000) and scanning electron Microscope (JEOL, Japan) was used to record the shear bond strength of 5 groups. Forty specimens were made for each group ; group 1 was treated with sandblasting only, group 2 was coated with V-primer after sandblasting, group 3 was coated with Metal primer, group 4 wase coated with MR Bond and group 5 was coated with silane. After treated with various methods, thermocycling was done for half of the each group. The surfaces of failed pattern were observed with SEM. The results were as follows: 1. Shear bond strength of the group 1 was lower than that of another groups in type IV gold alloys and bond strength of the group 1, 2 were lower than that of group 3, 4, 5 in Cr-Co alloys. 2. Shear bond strength of the gold alloy with resin was higher than that of Cr-Co alloy when specimens were coated with V-primer. 3. Shear bond strength of the Co-Cr alloys with resin was higher than that of gold alloys when specimens were coated with Metal primer. 4. The bond strength of all specimens did not decreased significantly after thermocycling. 5. Adhesive failures were found in group 1 and Cr-Co alloy in group 2, but adhesive and cohesive failures ere found in another groups.
Adhesives
;
Alloys
;
Gold Alloys
;
Mouth
;
Polymethyl Methacrylate*
5.A morphologic evaluation of defects created by a piezoelectric ultrasonic scaler on casting gold alloy.
Young Sung KIM ; Soo Hwan KIM ; Won Kyung KIM ; Young Kyoo LEE
The Journal of the Korean Academy of Periodontology 2009;39(4):385-390
PURPOSE: In this study we evaluated the morphologic aspects of defects created by a piezoelectric ultrasonic scaler with scaler tip on casting gold alloy using scanning electron microscope (SEM) images and defect surface profiles. METHODS: 54 blocks of type III casting gold alloy (Firmilay, Jellenko Inc, CA, USA) were scaled by a piezoelectric ultrasonic scaler (P-MAX, Satelec, France) with scaler tip (No. 1 tip) on a sledge device. 2-dimensional profiles of defects on all samples were investigated by a surface profilometer (a-Step 500, KLA-Tencor, CA, USA). The selected working parameters were lateral force (0.5 N, 1.0 N, 2.0 N), mode (P mode, S mode), and power setting (2, 4, 8). SEM images were obtained. Defect surface profiles were made on Microsoft Excel program using data obtained by a surface profilometer. RESULTS: Among P mode samples, there were similarities on defect surface profiles and SEM images regardless of lateral force. The defects created in P mode were narrow and shallow although the depth and the width increased as power setting changed low (2) to high (8). In P mode samples, the defect depth was the greatest when lateral force of 0.5 N was applied. However all the depths were smaller than 1 m. SEM images of Lateral force of 0.5 N, S mode, power setting 2 and 4 were similar to that of P mode, but the other SEM images of S mode showed discernible changes. Defect depth of S mode samples was the greatest when lateral force of 1.0 N was applied. CONCLUSIONS: Within the limitations of this study, it can be concoluded that removing capability of piezoelectric scaler with scaler tip becomes maximized as power level becomes higher but the capability is restricted when excessive lateral force is applied on scaler tip.
Alloys
;
Dental Equipment
;
Electrons
;
Gold Alloys
;
Ultrasonics
6.Sexually transmitted infections: a medical anthropological study from the Tari research unit 1990-1991.
Papua and New Guinea medical journal 2002;45(1-2):128-33
This paper describes medical anthropological research conducted while I was based at the Tari Research Unit for six months in 1990-1991. The research aimed to gain a deeper understanding of the social factors surrounding the transmission of sexually transmitted infections, which had escalated following a local gold rush in 1989. Although HIV/AIDS was a very minor health issue in Papua New Guinea at that time, medical staff were aware of the likelihood of the disease becoming prevalent in the highlands in the near future. The research indicated that many people regarded sexually transmitted infections (STIs) as a nuisance, rather than a serious health risk. Discussions with chronic sufferers revealed that they were more concerned about the dangers of infertility than the immediate effects of the infections. The paper considers the risk-taking that the people of Tari, the Huli, were prepared to accept and suggests ways in which these risks might be minimized.
Research
;
Risk
;
Health
;
Gold preparation
;
SOCIAL
7.Development of solid - based paper strips for rapid diagnosis of Pseudorabies infection.
Yew Joon Tam ; Mohd Azmi Mohd Lila ; Abdul Rani Bahaman
Tropical biomedicine 2004;21(2):121-34
Pseudorabies (Aujeszky's disease) is an economically significant disease of swine known to cause central nervous disorders, respiratory disease, reproductive failure and mortality in infected pigs. In attempts to eradicate the disease from becoming endemic, early detection is important to prevent further economic losses and to allow for detection and removal of infected pigs in domestic herds. Thus, a rapid and sensitive technique is necessary for the detection of the virus. For rapid and simple examination, an immuno - chromatographic lateral - flow assay system based on immunologic recognition of specific pseudorabies virus antigen was developed by utilising, as signal generator, colloidal gold conjugated to secondary antibody to detect primary or sample antibody in the sera of pseudorabies infected animals. The pseudorabies virus used as a capture antigen in the test strip was first cultivated in VERO cell culture and then purified by sucrose gradient separation to produce the viral protein concentration of 3.8 mg/ml. The standard pseudorabies antigens reacted well with the hyperimmune serum (HIS). The antibody detection system is basically composed of colloidal gold - labelled antibodies fixed on a conjugate pad, and the complementary pseudorabies antigen immobilised onto a nitrocellulose membrane forming capture zone. If the target antibody is present in a specimen, the colloidal gold-labelled antibody will form a complex with the antibody sample. Subsequently, the formed complex will migrate to the capture zone and is then bound to the solid phase via antigen - antibody interaction. As a result, a signal marker is generated by the accumulation of colloidal gold for detection confirmation. The results obtained demonstrated that the optimum combination of pseudorabies antigen needed as the capture reagent and gold conjugate as secondary antibody recognition marker was at a concentration of 0.38mg/ml and at 1:10 dilution factor respectively. The sensitivity of the solid - based test strip towards pseudorabies antibodies was high with a detection limit of 1 to 10,000 - dilution factor. The specificity of the assay was 100% with no cross - reaction being observed with other sera or antibodies. Accurate reading time needed for confirmation of the assay can be completed in 5 min with a whole blood sample of 25 microl. The colloidal gold - labelled antibody is stable at room temperature for 6 months or more (data not shown). Findings from this study indicated that the solid - based test strip assay system provided high sensitivity and specificity for the detection of pseudorabies at low levels of antibody concentration. The assay was rapid, simple, cheap, and does not require any sophisticated equipment. Thus, the solid based test strip will be a useful serological screening technique or for rapid diagnosis of an infectious disease in target populations of animals characterised by heterogeneous antibody responses.
Antibodies
;
Gold preparation
;
Solid
;
Antigens
;
assay
8.Distinguishment of XU Qiu-fu's thirteen ghost points.
Chinese Acupuncture & Moxibustion 2023;43(6):709-714
In addition to the well-known thirteen ghost points in Qianjin Fang (Important Formulas worth a Thousand Gold Pieces), "XU Qiu-fu's thirteen ghost points" is recorded in other medical books. The contents of "XU Qiu-fu's thirteen ghost points" are not exactly same among these medical books, which mainly focus on the nomination and selection of the ghost points. Even though, there are many similarity when compared with the thirteen ghost points in Qianjin Fang in terms of acupoint selection, acupoint location and the sequence of needle insertion, as well as the therapeutic methods. The authors believe that "XU Qiu-fu's thirteen ghost points" is actually adapted based on the framework of the thirteen ghost points in Qianjin Fang.
Acupuncture Points
;
Books
;
Gold
;
Needles
;
Records
9.Development of a colloidal gold based immunochromatographic strip for 8-OHdG detection.
Weiwei YE ; Liwen WANG ; Yu ZHANG ; Chaofeng LI ; Tianrun QIAN ; Xianshu FU ; Mingzhou ZHANG ; Jihong SHAN
Chinese Journal of Biotechnology 2022;38(3):1197-1208
8-hydroxy-2'-deoxyguanosine (8-OHdG) is a sensitive and stable biomarker for evaluating DNA oxidative damage. A rapid and sensitive colloidal gold immunochromatographic strip was developed for 8-OHdG detection by a competitive method. The sample pad (glass cellulose film), bonding pad (glass cellulose film), nitrocellulose film and absorbent pad were pasted on the polyvinyl chloride (PVC) base plate to construct the test strip. Colloidal gold (AuNPs) was prepared by the reduction of chloroauric acid with sodium citrate. 8-OHdG antibody (Ab) was coated on the outer layer of AuNPs to form Ab@AuNPs as a probe. Bovine serum albumin (BSA) and 8-OHdG were conjugated with carbodiimide hydrochloride to prepare an artificial antigen, which was used as the coating antigen of detection line. Goat anti mouse polyclonal antibody IgG was used as the coating antibody of control line. The experimental parameters were optimized including the type of nitrocellulose membrane, the formula of loading solution, and the spraying amount of gold labeled antibody. The results showed that the appropriate nitrocellulose membrane was CN 95. The optimal loading solution included BSA (1%), Tween-20 (3%), sucrose (3%) and NaCl (0.9%). The optimal spraying amount of gold labeled antibody was 4 μL. 8-OHdG can be detected by the strip under visible light, and the level of 8-OHdG in urine can be preliminarily determined by comparing the color intensity of T line and C line. The 8-OHdG concentration in urine was further calculated by the gray value of T line and the threshold of detection was 2.55 μg/L. This colloidal gold immunochromatographic strip is simple, rapid and specific for detecting 8-OHdG in human urine to preliminarily evaluate the human status.
8-Hydroxy-2'-Deoxyguanosine
;
Animals
;
Antibodies, Monoclonal
;
Gold
;
Gold Colloid/chemistry*
;
Metal Nanoparticles
;
Mice
;
Sensitivity and Specificity
10.COMPARISON OF WEAR RESISTANCE AMONG RESIN DENTURE TEETH OPPOSING VARIOUS RESTORATIVE MATERIALS.
Chul Young LEE ; Moon Kyu CHUNG
The Journal of Korean Academy of Prosthodontics 1999;37(3):313-327
The aim of this study was to compare wear resistance of resin denture teeth opposing various restorative materials. The wear resistance of conventional acrylic resin teeth (Trubyte Biotone) and three high-strength resin teeth(Bioform IPN, Endura, SR-Orthosit-PE) opposing different restorative materials (gold alloys, dental porcelain, composite resin) was compared. Wear tests were conducted with a sliding-induced wear testing apparatus which applied 100,000 strokes to the specimen in an mesio-distal direction under conditions of 100 stroke/min and constant loading of 1Kgf/tooth. Wear resistance of the resin denture teeth was evaluated by the following criteria : 1) wear depth, 2)weight loss, and 3) SEM observation. Results were as follows. 1. When opposed to gold alloys and composite resin, high-strength resin teeth showed superior wear resistance compared to acrylic resin teeth. But, in cases opposing dental porcelain, differences between the wear of the high-strength and acrylic resin teeth were not statistically significant (p<0.05). 2. When comparing wear resistance among high-strength resin teeth, opposing gold alloys, Endura was slightly more resistant and while in cases opposing dental porcelain, SR-Orthosit-PE was showed to be slightly resistant(p<0.05). 3. The wear of high-strength resin teeth was greater by 5 to 7 times when opposing porcelain and 2 to 3 times when opposing composite resin compared to gold alloys(p<0.05). 4. SEM observations of the wear surface showed that wear of resin teeth opposing gold alloys is a fatigue type of wear and wear of resin teeth opposing dental porcelain is fatigue and abrasion type of wear. Trubyte Biotone showed more severe fatigue type of wear than high-strength resin teeth. In conclusion, the use of dental porcelain should seriously be considered as restorative material in cases opposing resin denture teeth and improvement seems to be needed on resin teeth in the areas of wear resistance.
Dental Alloys
;
Dental Porcelain
;
Dentures*
;
Fatigue
;
Gold Alloys
;
Stroke
;
Tooth*