1.Clinical Application of Mutli-slice Spiral CT in Cerebral Angiography
Gennian QIAN ; Ziqian CHEN ; Chunlei ZHAO ; Zelong CHEN
Chinese Medical Equipment Journal 1993;0(06):-
Objective To evaluate the technique of multi-slice spiral CT angiography and it's value in diagnosing cerebrovascular diseases.Methods 77 cases were studied with GE Discovery Ultra 16-slice spiral CT scanner.The raw data were then transferred to ADW4.1 workstation and reconstructed with Volume Rendering(VR) and Maxium intensity projection(MIP)and Multiplanner Reconstraction(MPR).Results In 77 cases,49 were aneurysms,19 were AVM,7 were vaso-occlusive,2 were Moya-moya disease.Cerebrovascular was dispayed clearly in VR MIP and MPR.The images acquired with VR were more colorful and spatial than MIP and MPR,but the diagnosis value of MIP and MPR were higher.Conclusion MSCTA is an available noninvasive method in diagnosing the cerebrovascular disease.It could define character and position.MSCTA is an effective method and can be an nalterntive of DSA partially.
2.Comparative study of resting-state functional MRI and positron emission tomography-CT in the localization of temporal lobe epileptic focus
Chunlei ZHAO ; Ziqian CHEN ; Zhimin WANG ; Gennian QIAN ; Ping NI ; Chaochao TAO
Chinese Journal of Radiology 2013;(3):211-215
Objective To evaluate the efficacy of PET-CT brain imaging and resting-state fMRI in preoperative localization of temporal lobe epileptic (TLE)focus.Methods PET-CT and resting-state fMRI were performed in 17 patients with refractory TLE,who then underwent surgical treatment.Seventeen healthy volunteers matched with gender and age were recruited as the control group.The resting-state fMRI images were post processed by SPM5 software.Regional homogeneity(ReHo) values of the whole brain and bilateral hippocampus were obtained and analyzed.PET-CT images were analyzed by visual analysis method and asymmetry index method and the standardized uptake value (SUV) of bilateral hippocampus were obtained.The ReHo values and SUV of the bilateral hippocampus were compared by two independent samples t-test,and analyzed by receiver operating characteristic curve (ROC) for optimized diagnostic threshold.Pearson correlation analysis was employed for evaluating the correlation between the SUV and ReHo values of bilateral hippocampus.The consistency between the diagnostic accuracy of PET-CT and resting-state fMRI was assessed by Kappa consistency test.The outcome of the patient group was compared with that of the control group,and with the pathological results,to evaluate the diagnostic value of the two modalities for preoperative localization of temporal lobe epileptic focus.Results Regional or comprehensive low metabolism of 18F-FDG in temporal lobes was presented in all 17 patients,and 11 patients out of 17 showed lateral decreased ReHo value.The diagnostic accuracy of the two examinations was 70.6% (12/17) and 64.7% (11/17) for PET-CT and resting-state fMRI respectively compared with pathological results,and could be increased to 76.5% (13/17) when the two methods were combined for diagnosis.The ReHo values of the TLE group (0.34 ± 0.12)were significantly lower than those of the control group (0.46 ± 0.07) (t =3.230,P =0.003).The sensitivity and specificity of resting-state fMRI were 88.2% and 94.1% respectively when the ReHo value was 0.36.There was significant difference between the SUV of the affected (4.17 ±0.63) and healthy side(4.77 ±0.56) of hippocampus in TLE group(t =2.930,P =0.006).The sensitivity and specificity of PET-CT were 88.2% and 64.7% respectively when SUV was 4.23.The two values could be used as a threshold in the localization of temporal lobe epileptic focus.Consistency of lesion detection was revealed between PET-CT and resting-state fMRI though it was not high,and the Kappa value was 0.49.However,no correlation was detected between the SUV and ReHo value using Pearson correlation test(r =0.280,P =0.314).Conclusion Combined PET-CT brain imaging and resting-state fMRI as a multi-modality imaging method might improve the diagnostic accuracy of the TLE focus's localization.
3.CT and positron emission tomography-CT imaging features of pulmonary mucormycosis
Shangwen XU ; Ziqian CHEN ; Qun ZHONG ; Gennian QIAN ; Qinghong LIU ; Pan ZHANG ; Chunlei ZHAO
Chinese Journal of Radiology 2014;48(7):551-554
Objective To improve the diagnostic accuracy of pulmonary mucormycosis(PM) by investigating imaging appearances of PM,including CT and PET-CT.Methods A retrospective analysis of unenhanced MSCT(n=14),dynamic enhanced MSCT(n=10) and 18F-FDG PET-CT(n=3) examinations was conducted in 14 patients with surgically and pathologically proven PM.Results CT findings:13 patients had multiple patchy consolidation.Nine had thick-walled cavitiess(n=26) and 4 had pulmonary embolism,1 had solitary irregular masses,3 had adjacent bronchus invasion,4 had pleural effusion,14 had no mediastinal adenopathy.All the patients after renal transplantation had varied ground-glass opacifications and interlobular septal thickenings.The solid portion of lesions had strong enhancement with CT attenduation of (25±8) HU.PET-CT findings:3 cases were found with homogeneously or inhomogeneously increased 18F-FDG uptake(SUVmax 6.2,4.6,3.6).Conclusions PM presents with widespread but lacked specific imaging features.A suggestive diagnosis could be made in some patients with imaging appearances of multiple thick-walled cavities,rapid changes,and complicated with pulmonary embolism or invaded bronchus and sleevelet sign.
4.Applied Research of Dual-beam Technology to Produce Radioactive Nuclide in Medical Cyclotron
Zelong CHEN ; Ziqian CHEN ; Zhongdong YANG ; Gennian QIAN ; Renzhi WAN ; Chunlei ZHAO
Chinese Medical Equipment Journal 1989;0(03):-
Objective To develop the dual-beam technology of cyclotron to produce radioactive nuclide, which can increase radiopharmaceuticals output. Methods A new target is installed in cyclotron standby target, and at the same time the tubes and electronic components are fixed to produce radioactive nuclide through dual-beam technology, the product is tested by the dose calibrator. Results The radioactive nuclide can be produced through dual-beam technology and the output is nearly double times about which a single target. Conclusion The productions of cyclotron radioactive isotope are improved by dual-beam technology and meet the clinical needs of PET/CT examination for drugs.