1.EFFECTS OF SUCROSE POLYESTER (SPE) ON CHOLESTEROL LEVELS IN SERA OF RATS
Renjiang YU ; Fengqin LI ; Genfa XIE ; Qiang ZHANG ; Hui WANG ; Liangyu ZHAO ; Xianjuen QU ; Dachui ZHANG ;
Acta Nutrimenta Sinica 1956;0(01):-
The effect of sucrose polyester (SPE) on cholesterol levels in sera of rats under hypercholesteremic diet and of artificial hypercholesterolemia was observed. The results showed that in experiment Ⅰ when SPE 3 gra/rat/day was administered orally in accompanying with hypercholesteremic diet for 20 days, the elevation of cholesterol levels in sera of rats were obviously less than that of the group without SPE (P
2.EffectofhighGintensityfocusedultrasoundablationonuterinefibroidswithdifferentsignalintensityonT2WI
Genfa YI ; Wei ZHAO ; Hongjie FAN ; Xuancheng XIE ; Jiangping CUN ; Tao WANG
Journal of Practical Radiology 2019;35(3):437-440
Objective ToinvestigatetheeffectofhighGintensityfocusedultrasound (HIFU)ablationonuterinefibroidswithdifferent withdifferentT2Gweightedimage(T2WI)signalintensity.Methods 357patientswithsymptomaticuterinefibroidstreatedwith HIFU wereretrospectivelyanalyzed.AccordingtoT2WIsignalcharacteristics,fibroidsweredividedinto4groups:hypointensity,isointensity, hyperintensityand mixedintensity.The HIFUtreatmentparametersandablationeffectsofeachgroup werecomparedby O n eG W a y analysisofvariance.Results Theaverageageofthepatientswas(38.5±6.2)y,andtherewerenosignificantdifferencesinbaseline data(P>0.05).AllpatientssuccessfullycompletedHIFUtreatment,withtheaveragetreatmenttimeof(128.3±60.9)min,theaverage nonGperfusionvolumerate(NPVR)of(74.4±14.7)%,andtheaverageenergyefficiencyfactor(EEF)of(7.1±4.8)j/mm3.Theresults of O n eG W a y analysisofvarianceshowedthattheT2WIhypointensitygrouphadshortersonicationtime,treatmenttimeand1cm3 sonicationtime,smallertreatmentpowerandEEF,largerNPVR,comparingwiththehyperintensitygroup withstatisticallysignificant differences(P<0.05).Conclusion UterinefibroidswithT2WIhypointensityhavelowwatercontentandhighenergydepositionefficiency, whicharemoresuitableforHIFUablation.
3.The influence of uterus position on HIFU ablation effect of uterine fibroids
Genfa YI ; Wei ZHAO ; Hongjie FAN ; Xuancheng XIE ; Jiangping CUN ; Tao WANG
Journal of Interventional Radiology 2019;28(3):280-283
Objective To compare high-intensity focused ultrasound (HIFU) ablation effect on uterine fibroids between patients with different uterus positions. Methods The clinical data of 372 patients with symptomatic uterine fibroids, who were treated with HIFU at authors' hospital, were retrospectively analyzed. According to the position of the uterus, the patients were divided into anteverted group, mid-position group and retroverted group. Single factor analysis of variance was used to compare the baseline data of fibroids and HIFU ablation results between each other among the three groups. Results Successful HIFU treatment was accomplished in all patients. The average age of the patients was (39±6) years. Single factor analysis of variance indicated that no statistically significant difference in baseline data of fibroids existed between each other among the three groups (P>0.05) . The one cm3 sonication time and energy efficiency factor (EEF) in the anteverted group were significantly smaller than those in the retroverted group, the differences were statistically significant (P =0.007 and P =0.017 respectively) . Conclusion Uterine fibroids within an anteverted uterus are more likely to be ablated by HIFU.