1.Barium peritonitis--following barium enema of the proximal colon through a colostomy.
Liew NC ; Gee T ; Sandra K ; Gul YA
The Medical Journal of Malaysia 2003;58(5):766-768
Perforation with extravasation of barium is a rare complication of contrast enema examination of the large bowel with a high associated mortality rate. The experience of performing a re-laparotomy in a patient previously exposed to barium peritonitis is even less common. We describe an elderly male patient with a Hartmann's procedure performed a year previously, presenting with peritonitis following barium enema evaluation of the proximal colon via an end descending colon stoma. Emergency laparotomy, segmental bowel resection and liberal peritoneal toilet resulted in a satisfactory outcome. The patient had a subsequent successful reversal of his Hartmann's procedure nine months later despite the presence of dense barium induced adhesions. This potentially preventable iatrogenic complication is discussed in this report, which is supplemented by a brief review of the English literature.
Barium Sulfate/administration & dosage
;
Barium Sulfate/*adverse effects
;
Colon
;
Colostomy
;
Enema/*adverse effects
;
*Iatrogenic Disease
;
Peritonitis/*chemically induced
2.Enhanced compatibility and initial stability of Ti6Al4V alloy orthodontic miniscrews subjected to anodization, cyclic precalcification, and heat treatment.
Eun Ju OH ; Thuy Duong T NGUYEN ; Seung Youp LEE ; Young Mi JEON ; Tae Sung BAE ; Jong Gee KIM
The Korean Journal of Orthodontics 2014;44(5):246-253
OBJECTIVE: To evaluate the bioactivity, and the biomechanical and bone-regenerative properties of Ti6Al4V miniscrews subjected to anodization, cyclic precalcification, and heat treatment (APH treatment) and their potential clinical use. METHODS: The surfaces of Ti6Al4V alloys were modified by APH treatment. Bioactivity was assessed after immersion in simulated body fluid for 3 days. The hydrophilicity and the roughness of APH-treated surfaces were compared with those of untreated (UT) and anodized and heat-treated (AH) samples. For in vivo tests, 32 miniscrews (16 UT and 16 APH) were inserted into 16 Wistar rats, one UT and one APH-treated miniscrew in either tibia. The miniscrews were extracted after 3 and 6 weeks and their osseointegration (n = 8 for each time point and group) was investigated by surface and histological analyses and removal torque measurements. RESULTS: APH treatment formed a dense surface array of nanotubular TiO2 layer covered with a compact apatite-like film. APH-treated samples showed better bioactivity and biocompatibility compared with UT and AH samples. In vivo, APH-treated miniscrews showed higher removal torque and bone-to-implant contact than did UT miniscrews, after both 3 and 6 weeks (p < 0.05). Also, early deposition of densely mineralized bone around APH-treated miniscrews was observed, implying good bonding to the treated surface. CONCLUSIONS: APH treatment enhanced the bioactivity, and the biomechanical and bone regenerative properties of the Ti6Al4V alloy miniscrews. The enhanced initial stability afforded should be valuable in orthodontic applications.
Alloys*
;
Body Fluids
;
Hot Temperature*
;
Hydrophobic and Hydrophilic Interactions
;
Immersion
;
Osseointegration
;
Rats, Wistar
;
Tibia
;
Torque