1.Optimization of Parallel-Hole Collimator for Small Gamma Camera Based on Pixellated Crystal Array.
Yong Hyun CHUNG ; Cheol Ha BEAK ; Seung Jae LEE ; Jin Hyung PARK
Korean Journal of Medical Physics 2008;19(4):291-297
The purpose of this study is to optimize a parallel-hole collimator for small gamma camera having the pixellated crystal array and evaluate the effect of crystal-collimator misalignment on the image quality using a simulation tool GATE (Geant4 Application for Tomographic Emission). The spatial resolution and sensitivity were measured for the various size of hexagonal-hole and matched square-hole collimators with a Tc-99m point source and the uniformity of flood image was estimated as a function of the angle between crystal array and collimator by misalignment. The results showed that the spatial resolution and sensitivity were greatly improved by using the matched collimator and the uniformity was reduced by crystal-collimator misalignment.
Gamma Cameras
2.Evaluation of Renal Diseases with Scintillation Camera.
Youne Kyoon KIM ; Jung Sang LEE ; Won Dong KIM ; Chang Soon KOH
Korean Journal of Urology 1970;11(4):179-186
Radioisotope renogram and linear scan have been widely used for evaluating various renal disease, knowing that there was some disadvantages to be revised. Sequential study using scintillation camera readily reveals both functional and morphological alterations of the kidney with accuracy. The scintillation photographic studies on various renal conditions have been presented.
Gamma Cameras*
;
Kidney
3.Calculation of Renal Depth by Conjugate - View Method Using Dual - head Gamma Camera.
Hyun Mi KIM ; Tae Suk SUH ; Yong An CHUNG ; Sung Hoon KIM ; Soo Kyo CHUNG ; Hyoung Koo LEE ; Bo Young CHOE
Korean Journal of Nuclear Medicine 2001;35(6):378-388
No abstract available.
Gamma Cameras*
;
Head*
4.Some discussions of pathological morphism of thyroid through scintigraphic images on gamma camera
Journal of Vietnamese Medicine 1998;6(2):71-74
A study on the morphism of patients with thyroid diseases (most of them with long-term hyperthyroidism treated by antithyroid drugs and operation) was carried out on 60 scintigraphy with gamma camera. The results have shown that the scintigraphy was very good value to diagnose the thyroid nuclear, plummer, marine-lenhart syndrome and determine the proper dosage.
Thyroid Gland
;
Gamma Cameras
5.Biodistribution of 3-<131I>iodo-O-mythyl-L-alpha-methyltyrosine in Tumor Bearing Rats: A Comparison Study with L-3-<131I>iodo-alpha-methyltyrosine.
Chang Woon CHOI ; Seung Dae YANG ; Kwang Sun WOO ; Wee Sup CHUNG ; Soo Jung LIM ; Yong Sup SUH ; Kwon Soo CHUN ; Soon Hyuk AHN ; Jong Doo LEE ; Sung Soon HONG ; Sang Moo LIM
Korean Journal of Nuclear Medicine 1998;32(3):290-297
PURPOSE: The aim of this sutdy was to evaluate the feasibility of 3-[131I]Iodo-O-methyl-L-a-methyltyrosine ([131I]OMINT) as an agent for tumor image. MATERIALS AND METHODS: After synthesis of 4-O-methyl-L-a-methyltyrosine (OMAMT), OMAMT was labeled with 131I using Iodogen method. In viro cellular uptake study was performed using 9 L gliosarcoma cells at various time points upto 4 hr. The biodistribution (five rats implanted with the 9 L gliosarcoma cells per group) was evaluated at 30 min, 2 hr, 24 hr after iv injection of 3.7 MBq [131I]OMIMT or L-3-[131I]iodo-a-methyltyrosine ([131I]IMT). Gamma camera images were obtained at 30min, 2 hr, and 24 hr. RESULTS: [131I]OMINT uptake was 3.3 times and 2.5 times higher than [131I]IMT uptake at 30 min and 60 min, respectively and same after 2 hr in in vitro sutdy using 9L gliosarcoma cells. Maximum accumulation in tumor occurred at 30 min for both [131IOMINT and [131I]IMT in tumor bearing rats. The tumor uptake of [131I]OMINT was significantly higher than that of [131I]IMT in tumor bearing rats. The tumor uptake of [131I]OMIMT was significantly higher than that of [131I]IMT at early time point studied (3.74 +/- 0.48 vs 0.38 +/- 0.17% ID/g at 30 min and 2.40 +/- 0.17 vs 0.24 +/- 0.03% ID/g at 2 hr, respectively, p<0.01). However, the tumor uptake of both radiolabels were not significantly different at 24 hr (0.04 +/- 0.01 vs 0.05 +/- 0.01% ID/g). Tumor was visualized as early as at 30 min in gamma camera images. CONCLUSION: These data suggested that [131I]OMIMT might be a useful tumor imaging agent and has more advantage for the tumor imaging compared to [131I]IMT.
Animals
;
Gamma Cameras
;
Gliosarcoma
;
Rats*
6.Investigation of Scatter and Septal Penetration in I-131 Imaging Using GATE Simulation.
Ji Young JUNG ; Hee Joung KIM ; A Ram YU ; Hyo Min CHO ; Chang Lae LEE ; Hye Suk PARK
Korean Journal of Medical Physics 2009;20(2):72-79
Scatter correction for I-131 plays a very important role to improve image quality and quantitation. I-131 has multiple and higher energy gamma-ray emissions. Image quality and quantitative accuracy in I-131 imaging are degraded by object scatter as well as scatter and septal penetration in the collimator. The purpose of this study was to estimate scatter and septal penetration and investigate two scatter correction methods using Monte Carlo simulation. The gamma camera system simulated in this study was a FORTE system (Phillips, Nederland) with high energy, general-purpose, parallel hole collimator. We simulated for two types of high energy collimators. One is composed of lead, and the other is composed of artificially high Z number and high density. We simulated energy spectrum using a point source in air. We estimated both full width at half maximum (FWHM) and full width at tenth maximum (FWTM) using line spread function (LSF) in cylindrical water phantom. We applied two scatter correction methods, triple energy window scatter correction (TEW) and extended triple energy window scatter correction (ETEW). The TEW method is a pixel-by pixel based correction which is easy to implement clinically. The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejection window, which can overestimate or the underestimate scatter. The both FWHM and FWTM were estimated as 41.2 mm and 206.5 mm for lead collimator, respectively. The FWHM and FWTM were estimated as 27.3 mm and 45.6 mm for artificially high Z and high density collimator, respectively. ETEW showed that the estimation of scatter components was close to the true scatter components. In conclusion, correction for septal penetration and scatter is important to improve image quality and quantitative accuracy in I-131 imaging. The ETEW method in scatter correction appeared to be useful in I-131 imaging.
Gamma Cameras
;
Rejection (Psychology)
;
Water
7.The Effect of Blood Injection for the Prevention of Ethanol Reflux after Intrahepatic Ethanol Injection in the Rat.
Kool Jin AHN ; Choon Yyl KIM ; Bum Soo KIM ; Seong Tai HAHN ; Jae Mun LEE ; Kyung Sub SHINN
Journal of the Korean Radiological Society 1998;39(3):489-496
PURPOSE: To reduce ethanol reflux from the needle channel by injecting rat blood immediately after theinjection of ethanol into rat liver. MATERIALS AND METHODS: The first experiment involved 33 rat livers whichwere divided into four groups (three livers in group 1 ; ten in groups 2, 3, and 4). Group 1 animals were used ascontrols, and 0.1ml saline was injected into the liver ; in group 2, ethanol-Tc-99m-O4- mixed solution (0.1 ml,0.2 mCi) was injected into the liver ; in groups 3 and 4, the needle channel was blocked with 0.02 ml of freshblood and old blood, respectively, after the injection of ethanol. After removing the needle, a 3cm round filterpaper was laid on each injection site to absorb refluxed ethanol-Tc-99m-O4- mixed solution from the liver, andeach paper was then counted by a gamma camera unit. In the second experiment, 33 rats were divided into fourgroups (three rats in group 1 ; ten in groups 2, 3, and 4). Group 1 animals were used as controls, and afterexposing the left lateral lobe of the liver, 0.05 ml of saline was injected; in group 2, 0.05 ml of ethanol wasinjected into the liver in groups 3 and 4 the needle channel was blocked with 0.02 ml of fresh blood and oldblood, respectively, after the injection of ethanol. After ten days, peritoneal adhesions were scoredmacroscopically and microscopically. RESULTS: In the first experiment using ethanol-Tc-99m-O4- mixed solution,groups blocked with blood after the injection of mixed solution showed lower gamma counts than the group injectedwith mixed solution only (p-value = 0.0002). The group blocked with old blood showed the lowest count.Macroscopical and microscopical examination of peritoneal adhesions indicated that the grade of adhesion was lowerin groups blocked with blood than in the group injected with ethanol only (p-value = 0.0261 and 0.0163,respectively). CONCLUSION: The above results suggest that an injection of blood after an injection of ethanol isa very effective way of preventing reflux from the liver.
Animals
;
Ethanol*
;
Gamma Cameras
;
Liver
;
Needles
;
Rats*
8.Evaluation of a Conjugate View Method for Determination of Kidney Uptake.
Jung Kyun BONG ; Mijin YUN ; Jong Doo LEE ; Hee Joung KIM ; Hye Kyung SON ; Yun Young KWON ; Hae Jeong PARK ; Yu Seun KIM
Korean Journal of Nuclear Medicine 2005;39(3):191-199
PURPOSE: In order to obtain better quantitation of kidney uptake, this study is to evaluate a conjugate view method (CVM) using a geometric mean attenuation correction for kidney uptake and to compare it to Gate's method. MATERIALS AND METHODS: We used a Monte Carlo code, SIMIND and a Zubal phantom, to simulate kidney uptake. SIMIND was both simulated with or without scatter for the Zubal phantom. Also, a real phantom test was carried out using a dual-head gamma camera. The activity of 0.5 mCi was infused into two small cylinder phantoms of 5 cm diameter, and then, they were inserted into a cylinder phantom of 20 cm diameter. The results by the CVM method were compared with ideal data without both of attenuation and scatter and with Gate's method. The CVM was performed with or without scatter correction. The Gate's method was performed without scatter correction and it was evaluated with regards to 0.12 cm (-1) and 0.15 cm (-1) attenuation coefficients. Data were analyzed with comparisons of mean counts in the regions of interest (ROI), profiles drawn over kidney images and linear regression. Correlation coefficients were calculated with ideal data, as well. RESULTS: In the case of the computer simulation, mean counts measured from ideal data, the CVM and the Gate's method were (right: 998 +/- 209, left: 896 +/- 249), (right: 911 +/- 207, left: 815 +/- 265), and (right: 1065 +/- 267, left: 1546 +/- 267), respectively. The ideal data showed good correlation with the CVM and the correlation coefficients of the CVM, Gate's method were (right: 0.91, left: 0.93) and (right: 0.85, left: 0.90), respectively. CONCLUSION: The conjugate view method using geometric mean attenuation correction resulted in better accuracy than the Gate's method. In conclusion, the conjugate view method independent of renal depths may provide more accurate kidney uptake.
Computer Simulation
;
Gamma Cameras
;
Kidney*
;
Linear Models
9.Coded Aperture Gamma Camera for Thyroid Imaging: Monte Carlo Simulation.
Cheol Ha BEAK ; Seung Jae LEE ; Yong Hyun CHUNG
Korean Journal of Medical Physics 2008;19(4):247-255
A coded aperture camera has been developed to improve the signal-to-noise ratio (SNR) while keeping the spatial resolution of a pinhole gamma camera. The purpose of this study was to optimize a coded aperture camera and to evaluate its possibility for thyroid imaging by Monte Carlo simulation. A clinical gamma camera, a pinhole collimator with 1.0 mm hole diameter, and a 79x79 modified uniformly redundant array (MURA) mask were designed using GATE (Geant4 Application for Tomographic Emission). The penetration ratio, spatial resolution, integral uniformity and signal-to-noise ratio (SNR) were simulated and evaluated as a function of the mask thickness. The spatial resolution of the coded aperture camera was consistent with the various mask thickness, SNR showed a maximum value at 1.2 mm mask thickness and integral uniformity was improved by increasing mask thickness. Compare to the pinhole gamma camera, the coded aperture camera showed improved SNR by a factor of 30 while keeping almost the same spatial resolution. In this simulation study, the results indicated that high spatial resolution and ultra-high SNR of the thyroid imaging are feasible using a coded aperture camera.
Gamma Cameras
;
Masks
;
Signal-To-Noise Ratio
;
Thyroid Gland
10.Quantitative Lacrimal Scintigraphy, After Dacryocystorhinostomy and Conjunctivodaeryoeystorhinostomy with Jones' Tube.
Journal of the Korean Ophthalmological Society 1987;28(2):251-257
In this study, 55 patients (104 eyes) were studied in order to assess tear drainage, using a computer assisted gamma camera. Twentynine eyes had DCR, 29 eyes had CDCR with Jones' tube, and remaining 46 eyes were considered controls. We measured T1/2 values, the time in which a given amount of tracer drops to half in the conjunctival sac area. The time values were classified into 4 groups; Group I (3 min or less), Group II (3-6min), Group III (6-9min) and Group IV (9min or longer). In the patients with DCR and CDCR, tear drainage was faster than in the control group. Age was considered as a factor of delayed tear flow in those patients with DCR and controls, however, it was not a relevant factor in those patients with CDCR using Jones' tube.
Dacryocystorhinostomy*
;
Drainage
;
Gamma Cameras
;
Humans
;
Radionuclide Imaging*
;
Tears