2.Placement of peritoneal catheters with the assistance of X-ray fluoroscopy.
Meichu CHENG ; Xiao FU ; Junxiang CHEN ; Jun LI ; Fuyou LIU ; Xun ZHOU
Journal of Central South University(Medical Sciences) 2012;37(12):1265-1268
OBJECTIVE:
To evaluate the value of X-ray fluoroscopy in preventing catheter dysfunction during catheterization of peritoneal dialysis.
METHODS:
A total of 168 patients with end-stage renal failure were nonrandomized into group A (the conventional catheterization group) and group B (the conventional catheterization + bedside fluoroscopy group). All patients were followed up for 1 year after the catheterization. Details of the patients' general information, catheter-related complications and incidence of catheter dysfunction were analyzed.
RESULTS:
Hemorrhagic complications occurred in 9 patients (5.36%), including 2 incision hematomas, 4 bloody fluid drainages, 1 bladder perforation and 1 intestinal perforation (1.20%). Dialysate leakages occurred in 4 patients (2.38%): 2 right pleural effusion and 2 scrotal edemas. Infection-related complications (2.98%) in 5 patients were observed: 1 infectious peritonitis and 4 catheter exit infections. All peritoneal dialysis-related infections were cured after the treatment. There was no significant difference in the incidence of mechanical and infectious complications between the two groups (P> 0.05). No immediate catheter dysfunction was found in all patients, but late catheter dysfunction was observed in 14 patients (8.33%), including 9 catheter migrations (5.36%), 5 of which were induced by other reasons (2.98%). Catheter dysfunction in 11 out of the 14 patients occurred within 30 days post-catheterization, whereas 2 occurred over 30 days (caused by constipation). In group A, 12 patients developed delayed catheter dysfunction (11.65%), 10 of which (83.33%) were induced by catheter migration and the other 2 by other reasons. In group B, 2 (11.65%) delayed catheter dysfunctions were observed, including 1 catheter migration and 1 constipation. The incidence of catheter dysfunction in group A was significantly higher than that in group B (P<0.05). The success rate of catheterization in group B was 91.3%.
CONCLUSION
Catheter dysfunction is a common complication in peritoneal dialysis. X-ray fluoroscopy during catheter insertion helps to monitor the location of the catheter, which can effectively prevent late catheter dysfunction and increase the success of catheterization in peritoneal dialysis.
Aged
;
Catheters, Indwelling
;
Female
;
Humans
;
Kidney Failure, Chronic
;
therapy
;
Male
;
Middle Aged
;
Peritoneal Dialysis
;
methods
;
Radiography, Interventional