1.Clinical analysis of superior mesenteric venous thrombosis
Zujun QIAO ; Yijun YANG ; Fengping JIAO ; Chaoyang HAN ;
Chinese Journal of General Surgery 2001;0(07):-
Objective To study the diagnosis and treatment of superior mesenteric venous thrombosis (MVT). Methods The clinical data of 13 MVT cases were retrospectively analyzed. Results The diagnosis of MVT in all 13 cases were comfirmed by surgery. Of them,diagnosis for 6 cases was made preoperatively, and misdiagnosed preoperatively in 7.11 patients were cured, and 2 died. Conclusions Because the symptom does not accord with physical sign in the early stage of MVT, the diagnosis of MVT is difficult . B US and CT are useful in the diagnosis of MTV.Intra and post operative coagulation treatment is the key to prevent the recurrence and to reduce the mortality.
2.Evaluation of Quality Coherence of Commercially Available Artemisia apiacea Decoration Pieces in Chongq-ing by HPLC Fingerprint Combined with Common Model Recognition
Chengyou JIA ; Fengping ZHAO ; Wei LI ; Jiao CHEN ; Rongping YANG ; Yunhong WANG
China Pharmacy 2015;(27):3828-3830,3831
OBJECTIVE:To establish the fingerprint of Artemisia apiacea to identify common model and evaluate the quality coherence of the commercially available A. apiacea decoration pieces in Chongqing. METHODS:HPLC method was performed on the column of Waters XTerra C18 with the mobile phase consisted of methanol-0.1% phosphoric acid(gradient elution)at the flow rate of 1.0 ml/min. The detection wavelength was 220 nm,column temperature was 30 ℃ and the sample size was 10 μl. The simi-larity of 12 batches of samples was evaluated by TCM Chromatogram Fingerprint Similarity Evaluation System(2004A edition);a common model of fingerprints was identified by principal component analysis(PCA)and cluster analysis(CA). RESULTS:Total-ly 11 batches of samples were screened to establish common model of fingerprints and 16 common peaks were obtained,among which,3 common components were identified;RSDs of precision,stability and reproducibility tests were lower than 2.53%. The similarity of 11 batches of A. apiacea and reference chromatogram was more than 0.990. CONCLUSIONS:The method is stable and easy,and can provide reference for the scientific quality evaluation and control of A. apiacea;the quality of commercially available A. apiacea decoration pieces is generally good,however,there is still a little number of batches with poor quality. The production procedures and supervision of A. apiacea decoration pieces should be strengthened.