1.Serological Survey of Antibodies IgG and IgM to Toxoplasma among Population of Cangzhou City
Zhenglin XU ; Fenge SUN ; Xiumin HU
Journal of Environment and Health 1992;0(02):-
Objective The aim of this research was to provide a basis for the development of preventive and curative measures against the toxoplasma infection by investigating the current infection of toxoplasma and its epidemic characteristics among the population of the Cangzhou city.Methods Antibodies IgG and IgM against toxoplasma in the sera were determined by ELISA during Jan.-May,2007.Results Six hundred and thirty-servn subjects were screened.The positive rate was 6.3% for total antibodies,5.2% for IgG and 1.1% for IgM.The infection rate was higher in the population aged 19-24 years and 49-60 years.The positive rate was higher in farmers living in countryside,those who were poor educated and who had bad habit of cooking food without separating knives and chopping boards to handle raw food and ready-to-eat food and washing their hands after cutting raw meat(P
2.Determination of ethyl pyruvate in chitosan nanoparticles by reversed-phase high-performance liquid chromatography
Fenge XU ; Bingxin ZHAO ; Shumao SUN ; Yongchun MENG ; Kaihui NAN ; Ayong YU ; Jia QU
Chinese Journal of Tissue Engineering Research 2014;(8):1205-1210
BACKGROUND:Research on ethyl pyruvate detection methods is reported rarely, and moreover, literature about reversed-phase high-performance liquid chromatography (RP-HPLC) for detection of ethyl pyruvate is less.
OBJECTIVE:To establish an RP-HPLC method for determination of ethyl pyruvate in ethyl pyruvate-chitosan nanoparticles.
METHODS: The chromatographic analysis was performed on a ZORBAX Eclipse XDB-C18 column (4.6 mm× 150 mm, 5μm) at 25℃, with the mixture of acetonitrile and water (40:60, V/V) as the mobile phase at the flow rate of 1 mL/min. The determination wavelength wasset at 210 nm and the injection volume was 20 μL.
RESULTS AND CONCLUSION: The peak of ethyl pyruvate and the peaks of auxiliary materials and solvent were separated wel. The linear rang of ethyl pyruvate was 1-100 mg/L (r=0.999 6). The relative standard deviation of both the intra-and inter-day precision was less than 3% for low-, moderate-, and high-concentration ethyl pyruvate. The relative standard deviation of reproducibility test and stability test was 1.25% and 1.3%, respectively. Sample average recovery rates were (91.5±1.0)%, (3.5±0.2)%, (94.4±0.4)%, respectively. Encapsulation efficiency of samples were (87.2±0.22)%, (90.5±0.15)%, (91.1±0.17)%, respectively. The relative standard deviation of different sample content were 0.9%, 0.5%, 0.3%, respectively. The RP-HPLC method for determination of ethyl pyruvate is sensitive, accurate and highly specific with wide linear range and high sample average recovery.